Description

The H4905A is a portable, hydraulically powered device 

intended to pull various sizes and shapes of standard 

sign posts. Capable of developing 43.6 kN (9800 lb) of 

lifting force, the sign post puller uses either serrated 

jaws or a chain to grip the post. It features a built-in 

control valve.

Safety

Safety is essential in the use and maintenance of 

Greenlee Utility tools and equipment. This instruction 

manual and any markings on the tool provide informa-

tion for avoiding hazards and unsafe practices related to 

the use of this tool. Observe all of the safety information 

 provided.

Purpose of this Manual

This manual is intended to familiarize personnel with 

 

the safe operation and maintenance procedures for the 

following Greenlee Utility tool:
 

H4905A (42237) Sign Post Puller

Keep this manual available to all personnel.

Replacement manuals are available upon request at no 

charge at www.greenlee.com.

Other Publications

Tool Owners/Users

SAE Standard J1273 (Hose and Hose Assemblies):

 

Publication 99930323

Authorized Greenlee Utility Service Centers

Service Manual:  Publication 99916045

All specifications are nominal and may change as design 

improvements occur. Greenlee Textron Inc. shall not be liable for 

damages resulting from misapplication or misuse of its products.

KEEP THIS MANUAL

Table of Contents

Description .................................................................... 2

Safety

 ............................................................................ 2

Purpose of this Manual

 ................................................. 2

Other Publications

 ......................................................... 2

Important Safety Information

 .....................................3–5

Identification

 .................................................................. 6

Specifications

 ................................................................ 7

Hoses and Fittings ........................................................

8

Hose Connections .........................................................

8

Typical Setup

 .................................................................

8

Operation ..................................................................9–10

Maintenance 

 ............................................................... 10

Troubleshooting ........................................................... 11

Illustration and Parts List

 ........................................12–13

Summary of Contents for Greenlee H4905A

Page 1: ...ulic Sign Post Puller 99936755 REV 3 2010 Greenlee Textron Inc 1 10 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register t...

Page 2: ...ed to familiarize personnel with the safe operation and maintenance procedures for the following Greenlee Utility tool H4905A 42237 Sign Post Puller Keep this manual available to all personnel Replace...

Page 3: ...lt in severe injury or death Electric shock hazard This tool is not insulated Do not use this tool near energized electrical lines Failure to observe this warning could result in severe injury or deat...

Page 4: ...lb minimum breaking strength An underrated chain may break during operation Failure to observe this warning could result in severe injury or death Do not exceed the following hydraulic power source m...

Page 5: ...ended purpose only Use other than that which is described in this manual may result in injury or property damage Make sure all bystanders are clear of the work area when handling starting and operatin...

Page 6: ...n Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 6 Identification 1 Base 2 Chain 3 Serrated Jaws 4 Cylinder 5 Handle 6 Guide 7 Serial Number 8 Bracket 9 Control Lever 10 Pressure suppl...

Page 7: ...8 bar 200 psi 13 8 bar 200 psi is the maximum agreed stan dard back pressure for the HTMA Hydraulic Tool Manufacturers Association Greenlee Utility tools will operate satisfactorily at this standard...

Page 8: ...ing Hoses 1 Move the flow lever on the hydraulic power source to the OFF position 2 Stop the hydraulic power source 3 Connect the tank hose to the tank return port on the hydraulic power source and th...

Page 9: ...s connected to a power source Accidental start up can result in serious injury Failure to observe this warning could result in severe injury or death Make sure all bystanders are clear of the work are...

Page 10: ...ection when operating or servicing this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Do not change accessories inspect adjust or clean too...

Page 11: ...the fluid level Check system for leaks Air in the hydraulic system Refer to the power source manufac turer s instructions for removing air from the system Incorrect hydraulic fluid viscosity Use hydr...

Page 12: ...ng Dr Rockford IL 61109 2988 USA 815 397 7070 12 Illustration 24 43B 43A 18 19 41 30 37 40 29 28 27 38 39 42 36 28 26 31 32 31 34 35 30 12 11 10 7 33 9 8 2 54 24 53 21 20 14 15 1 6 3 4 9 9 5 50 22 49...

Page 13: ...7 43151 50431510 Spool 1 28 O ring 437 x 562 x 062 70 2 29 40258 50402582 Lever bracket 1 30 Screw cap 1 4 20 x 500 socket head 8 31 43429 50434292 Washer flat 265 x 734 x 059 2 32 43836 50438360 Spac...

Page 14: ...ax 815 397 1865 Canada 800 435 0786 Fax 800 524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc...