127576 DC Bus Timeout
Continued
5.
Place pos. meter probe A on
controller terminal B+. Place neg.
meter probe B on controller B-.
Voltage should be the same as the
battery set. If not, replace -48V battery
wire to B-. If voltage is still not the
same verify steps 2 – 4.
6.
Disconnect resistor control module
black wire from B- on the controller. If
error status changes, replace the
resistor module. If error continues, see
step 7.
Resistor control wire
7. Try a known good controller if error is gone warranty
controller. Error remains reinstall controller and
contact Customer Care.