9024 AC Short Circuit
Caused by: Short circuit detected in controller, motor cables, motor, or failed solenoid
.
1.
Turn key off and back on
to reset the controller. If car
runs, return to service. If
not, proceed to remaining
steps.
2.
Disconnect all three motor wires.
Contact the V wire lug to the pos. meter
terminal. Contact the U lug to the
negative terminal. Meter ohm resistance
should be 0.0 – 0.2. If not, replace motor.
3.
Contact the V wire lug to the pos.
meter terminal. Contact the W lug to the
negative terminal. Meter ohm resistance
should be 0.0 – 0.2. If not, replace motor.
4.
Contact the U wire lug to the pos.
meter terminal. Contact the W lug to the
negative terminal. Meter ohm resistance
should be 0.0 – 0.2. If not, replace motor.
5. Try a known good controller if error is
gone
,
warranty controller. Error remains
,
reinstall controller
and
contact Customer Care.