CESSNA
SECTION 3
MODEL 208B 867 SHP
ABNORMAL PROCEDURES
GARMIN G1000
U.S.
FAA APPROVED
FLIGHT CONTROLS
(Continued)
FLAPS FAIL TO EXTEND OR RETRACT
1.
FLAP MOTOR Circuit Breaker . . . . . . . . . . . .
CLOSE
(push in)
(fifth row, fourth breaker from forward end)
2.
STBY FLAP MOTOR Circuit Breaker . . . . . . .
CLOSE
(push in)
(bottom row, fourth breaker from forward end)
IF FLAPS STILL FAIL TO EXTEND OR RETRACT
3.
Right STBY FLAP MOTOR Switch
a.
Switch Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MOVE
(breaking safety wire)
b.
Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STBY
4.
Left STBY FLAP MOTOR Switch
a.
Switch Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MOVE
(breaking safety wire)
b.
Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UP or DOWN
(hold switch UP or DOWN until flaps reach desired position,
release switch before flaps reach full up or full down travel.)
CAUTION
With the standby flap system in use, limit switches
which normally shut off the primary flap motor when
reaching the flap travel limits are electrically inactivated.
Therefore, the pilot must release the standby flap motor
up/down switch before the flaps reach their travel limit
to prevent overloading and damage to the flap system.
5.
Right STBY FLAP MOTOR Switch
. . . . . . . . .
LEAVE IN STBY
(until maintenance action can be accomplished)
IF FLAPS EXTEND OR RETRACT NORMALLY
3.
Continue flight as planned.
208BPHCUS-00
3-91
Summary of Contents for Cessna Grand Caravan Ex 208B
Page 2: ......
Page 351: ...CESSNA SECTION 5 MODEL 208B 867 SHP PERFORMANCE GARMIN G1000 U S Figure 5 23 208BPHCUS 00 5 63...
Page 352: ...SECTION 5 CESSNA PERFORMANCE MODEL 208B 867 SHP GARMIN G1000 U S Figure 5 24 208BPHCUS 00 5 64...
Page 353: ...CESSNA SECTION 5 MODEL 208B 867 SHP PERFORMANCE GARMIN G1000 U S Figure 5 25 208BPHCUS 00 5 65...