background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 8

FL-B101Q-DCA _ FL-B01Q-DCV (d0084)

Setting the Colors (For CHT or CVT Center Bar display options only)

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Apply power

while holding down

SP1, SP2, SP3, SP4

SP2
SP1

SP3

SP4

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. orange)

SP1

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Green)

SP2

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Orange)

SP3

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Red)

SP4

To comply with the latest safety requirements, the tri-color bargraph is designed like a traffic light, to 

display either red, orange or green, but only one color at a time.  When the bar reaches a selected 

color change point, the entire bar will change to the color designated for that zone.  This eliminates 

any ambiguity as to the signal status, especially just after transitioning to a new zone.

However, if two or more setpoints with differently specified colors are positioned at the same set point 

value, the color specified for the set point with the highest identifying number will be displayed. When 

set points are set to the same value, the SP4 color overrides the SP3 color, the SP3 color overrides 

the SP2 color, and the SP2 color overrides the SP1 color.

STEP A  ENTER COLOR SET MODE

  Hold down ALL four setpoint buttons (SP1, SP2, SP3 and SP4) and apply power to the  

  meter. The meter will light up in the Color Set Mode. Release all the setpoint buttons.

STEP B SELECT COLOR FOR BAR ABOVE SETPOINT 1

  Hold down the SP1 button. The color of the bar segments below SP1 will cycle between red,  

  green and orange. Release the SP1 button when the bar is the required color. Now    

  Whenever the bar is above the SP1 level it will be this color. When the bar is below the SP1  

  level it will always be red.

STEP C SELECT COLOR FOR BAR ABOVE SETPOINT 2

  Hold down the SP2 button. The color of the bar segments below SP2 will cycle between red,  

  green and orange. Release the SP2 button when the bar is the required color. Now    

  whenever the bar is above the SP2 level it will be this color.

STEP D SELECT COLOR FOR BAR ABOVE SETPOINT 3

  Hold down the SP3 button. The color of the bar segments below SP3 will cycle between red,  

  green and orange. Release the SP3 button when the bar is the required color. Now    

  whenever the bar is above the SP3 level it will be this color.

STEP E SELECT COLOR FOR BAR ABOVE SETPOINT 4

  Hold down the SP4 button. The color of the bar segments below SP4 will cycle between red,  

  green and orange. Release the SP4 button when the bar is the required color. Now    

  whenever the bar is above the SP4 level it will be this color.

STEP F  EXIT COLOR SET MODE

 

Turn off the power to the meter for 5 seconds and then re apply the power. The bargraph will now work with the programmed colors.

Summary of Contents for FL-B101Q-DCA

Page 1: ...s Analog Output Isolated 16 bit user scalable mA or V OIC mA out 4 20 mA 0 to 500 max loop resistance OIV volts out 0 10 V DC 500 or higher resistance Power Supply AC DC Auto sensing wide range supply...

Page 2: ...As there are no menu or sub menus to navigate the programming and setup is quick and Span Buttons Span Zero Buttons Zero Set Point Button SP1 SP2 SP3 SP4 Front Panel Buttons Zero Button The Zero Butt...

Page 3: ...alled Mode 3 Hysteresis Band between SP1 SP2 This mode enables the Hysteresis function In order for Hysteresis to function SP2 must be set to a value greater than SP1 and SP2 should be selected as Hig...

Page 4: ...ver and carefully lever the plastic catch up and tilt the Display Board assembly forward Then repeat this action with the bottom catches Step 5 Remove the entire Display Board assembly by sliding it o...

Page 5: ...or SPAN but ton is pressed the input signal being applied must be more than 5 higher or lower than the previously memorized value of the input signal that was being applied when the other button was...

Page 6: ...to 20mA If now the scaling has to be changed to read zero to full scale for an input of 0 to 20mA only the low 4 mA end needs to be recalibrated The high 20 mA end of the scaling is left untouched an...

Page 7: ...2 and SP4 activate when input is lower than set point SP1 and SP3 activate when input is equal to or higher than set point SP2 activate when input is lower than set point SP1 SP3 and SP4 activate when...

Page 8: ...SP2 color overrides the SP1 color STEP A ENTER COLOR SET MODE Hold down ALL four setpoint buttons SP1 SP2 SP3 and SP4 and apply power to the meter The meter will light up in the Color Set Mode Release...

Page 9: ...HI button adjust the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction o...

Page 10: ...T mA 0 to 20 mA 4 to 20 mA or V 0 to 10 V output is header selectable Pin 19 Programming LOCK By connecting the LOCK pin to the COMMON pin the meter s programmed parameters can be viewed but not chang...

Page 11: ...Pot Span Pot ID05 ID01 Zero Offset Pot Zero Offset Pot Input Range Header Input Range Header Input Range Header ID01 DC Volts 2 20 200V Custom w 24V DC Exc Custom 200V 20V 2V ON OFF 24V Exc 24V Exc D...

Page 12: ...or FI series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2...

Page 13: ...into a Hi and a Lo range This has the effect of dividing the adjustment range of the SPAN pot into ten equal 10 steps across 100 of the input Signal Span Range HI LO HI LO SPAN Turn Clockwise to Incre...

Page 14: ...5 150 1500 2 20 200 2000 2 5 25 250 2500 3 30 300 3000 4 40 400 4000 4 5 45 450 4500 5 50 500 5000 6 60 600 6000 7 5 75 750 7500 8 80 800 8000 9 90 900 9000 1 2 12 120 1200 Div Face plate scales and n...

Page 15: ...g 5 93 PLUG5P DR Extra Screw Terminal Conn 5 Pin Plug 6 DN CAS144X36 Complete 144x36mm Case with bezel 25 OP MTL144X36 Metal Surround Case includes screw mounting clips 25 OP MTLCLIP Screw Mounting Cl...

Reviews: