Case Dimensions

96 mm

(3.78")

48 mm

(1.89")

  3.9 mm

(0.15") typical

FRONT VIEW

1/8 DIN 96x48mm

    These dimensions are 

increased by 1.6mm (0.06") 

when the metal surround 

case is installed.

The 96x48mm case is 

particularly suitable for 

mounting in mosaic panels 

or insulative panels up to 2" 

thick. They can also stack 

mount, 2 up in existing 

cutouts for 1/4 DIN 

(96x96mm) or 4 up in 

1/2 DIN (96X192mm).

NOTE: The Metal Surround Case

is pre-installed at the factory and cannot 

be removed without damage to the case.

Metal Surround Case

P/N:(OP-MTL96X48)

 

uses 

Metal Screw Mount Clips 

and has a max. panel 

thickness mounting 

of 15.5 mm (0.61").

 

Removable 

Key-lock

Cam 

Opening

Safety

Catch

Clear Lockable NEMA 4X

Splash Proof Cover 

P/N:(OP-N4/96x48)

40.8 mm

(1.61")

117 mm

(4.61")

SIDE VIEW

5.3 mm

(0.21")

3.7mm

(0.15")

43.4 mm

(1.71")

DIN Cutout spacers

Straight-thru Connector for 

meters with output board

20mm (0.79")

Right-angled Connector 

11.8mm (0.47")

 

PANEL CUTOUT

Case will mount in standard 1/8 DIN cutouts

45 mm

(1.77")

Snug Fitting

Mosaic Fitting

92 mm

(3.62")

Loose Fitting

91.6mm

(3.6")

40.8mm

(1.61")

8 places

3mm

(0.12")

8 places

4mm

(0.16")

43.4mm

(1.71")

1/8 DIN 

Cutout spacers 

87.4mm

(3.45")

Various bezel 

colors are available. 

Black is standard.

Prog.

SP3

SP4

SP2

SP1

For additional strength, extra Mounting 

Slide Clips can be ordered and doubled up 

one behind the other. P/N: (75-DMTCLIPF)

TOP VIEW

87.4mm

(3.45")

mosaic 

fitting

95.4mm

(3.77")

Max. panel thickness

50mm

(1.97")

96 mm

(3.78")

91.6mm 

(3.6") 

DIN 

Cutout 

Spacer

To open rear cover, 

use a small flat 

bladescrew driver. 

Press down lightly to 

release catch on top 

or bottom of case 

and leaver outwards.

4.7mm 

(0.19")

DIN Cutout Spacer

2mm 

(0.08")

Connector 

Socket

Prog.

SP1

SP1

SP2

SP4

SP3

SP5

SP6

Prog.

SP1

SP1

SP2

SP4

SP3

SP5

SP6

Prog.

SP1

SP1

SP2

SP4

SP3

SP5

SP6

When extra panel 

mounting tightness is 

required, order the 

optional screw mount clip.

P/N:(OP-MTLCLIP)

High Strength Panel 

Mounting Kit

P/N: OP-PMA96X48

For extra strength in portable applications, the 8 DIN 

spacers should be snipped off and the Mosaic fitting

cutout used.  Alternatively, the High Strength Panel 

Mounting Kit (Part # OP-PMA96X48) can be used.

Panel adaptor plates are 

available to retrofit most 

existing panel cutouts.

Installation Guidelines

Installation

 

    

1. Install and wire meter per local applicable codes/reg-

ulations, the particular application, and good installation 

practices.

2. Install meter in a location that does not exceed the 

maximum operating temperature and that provides 

good air circulation.

3. Separate input/output leads from power lines to 

protect the meter from external noise.  Input/output 

leads should be routed as far away as possible from 

contactors, control relays, transformers and other noisy 

components.  Shielding cables for input/output leads is 

recommended with shield connection to earth ground 

near the meter preferred.

4. A circuit breaker or disconnect switch is required to 

disconnect power to the meter.  The breaker/switch 

should be in close proximity to the meter and marked as 

the disconnecting device for the meter or meter circuit.  

The circuit breaker or wall switch must be rated for the 

applied voltage (e.g., 120VAC or 240VAC) and current 

appropriate for the electrical application (e.g., 15A or 

20A).

5. See 

Case Dimensions section

 for panel cutout infor-

mation.

6. See 

Connector Pinouts section

 for wiring.

7. Use 28-12 AWG wiring, minimum 90˚C (HH) tempera-

ture rating.  Strip wire approximately 0.3 in. (7-8 mm).

8. Recommended torque on all terminal plug screws is 

4.5 lb-in (0.51 N-m).

Summary of Contents for DL-40JANUS-PROCESS

Page 1: ...l Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS PROCESS Two scaling methods MANUAL no external sig nal source required and AUTO requied an exter nal signal source Optional...

Page 2: ...ed by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the o...

Page 3: ...MAL POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal P...

Page 4: ...out STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to...

Page 5: ...wo Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from C...

Page 6: ...ress the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to...

Page 7: ...counts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locat...

Page 8: ...HYST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRE...

Page 9: ...e SP2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the d...

Page 10: ...g with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 2...

Page 11: ...es with 4 Independent 400V 210mA DC only SSRs DL 40JANUS Series 29 28 27 25 26 24 23 22 Options Order Code OR32 4A 4A 4A 4A 4A 4A OR34 4A 4A 4A 4A 4A 4A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules w...

Page 12: ...XC FullyUserScalable PIN 2 PIN 1 PIN 3 _ Exc On Off Header SPAN Pot HI LOW SPAN RANGE Header ZERO Pot ZERO ADJUST Header SPAN ADJUST Header ZERO OFFSET RANGE Header Decrease Increase Decrease Increase...

Page 13: ...ar 15 Turn Potentiometer 100 Counts 100 Counts 0 ZERO Potentiometer Pot If provided the ZERO pot is always to the left of the SPAN pot as viewed from the rear of the meter Typically it enables the inp...

Page 14: ...4 7mm 0 19 DIN Cutout Spacer 2mm 0 08 Connector Socket Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 Prog SP1 SP1 SP2 SP4 SP3 SP5 SP6 When extra panel mounting tightness is requir...

Page 15: ...case is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference...

Page 16: ...RELAY OUTPUT OPTIONS ACCESSORIES OA____ DL 40JANUS PROCESS Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different spec...

Reviews: