background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 3

   BX-B31 Data Sheet (BX3)

Component Layout

Custom

200V

20V

2V

ON

OFF

24V Exc

  < Increase  Span  Decrease > 

Typical input signal conditioner shown

Low Voltage 

Transformer is 

Colored Black

LV

Custom

200V

20V

2V

ON

OFF

24V Exc

  < Increase  Span  Decrease > 

Typical input signal conditioner shown

High Voltage 

Transformer is 

Colored Grey

HV

BX-B31-XX-PS2 (Low Voltage)

BX-B31-XX-PS1 (High Voltage)

Standard Face Plates and Scales

0

10

20

30

40

50

60

70

80

90

100

10x5 

  50

6x5 

30

7.5x5 

37.5

8x5 

40

9x5 

45

6x2x2 

24

4x5x2 

20

5x5x2 

25

6x5 

30

8x5 

40

9x5 

45

10x5 

50

5x3x2 

15

10 

100 

1000

1.5 

15 

150 

1500

20 

200 

2000

2.5 

25 

250 

2500

30 

300 

3000

40 

400 

4000

4.5 

45 

450 

4500

50 

500 

5000

60 

600 

6000

7.5 

75 

750 

7500

80 

800 

8000

90 

900 

9000

   1.2 

12 

120 

1200

Div.

0

10

20

30

50

80

100

70

60

40

90

0

2

4

6

8

10

12

0

3

6

9

12

15

0

5

10

15

20

0

5

10

15

25

20

0

5

10

15

30

20

25

0

5

10

15

20

35

30

25

40

0

5

10

15

20

35

40

30

25

45

0

5

10

15

25

40

50

35

30

20

45

0

10

20

30

40

50

60

0

10

20

30

40

50

60

70

75

0

10

20

30

40

70

60

50

80

0

10

20

30

40

70

80

60

50

90

• Unless otherwise specified, a standard 0-100 scaled face plate with white letters on a black background is provided with each meter.

In those cases where a temperature modules is ordered, a 0-300 °F (white on black) face plate will be provided as standard.

• Alternatively a face plate with black letters on a white background or a blank, white or black face plate, 

may be ordered as a no charge substitute. For temperature applications there are also several 
different optional face plates that may be ordered as a no charge substitute. (See below).
Customized face plates with special scaling can also be ordered.

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

0

30

60

90

120

150

°

C

°

F

0

50

100

150

300

200

250

0

30

60

90

120

150

°

C

°

F

0

50

100

150

300

200

250

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

76-BXB3/BH  standard

76-BXB3R/BH  standard

76-BXB3R/WH  optional

76-BXB3/WH  optional

76-BXB3/WV

optional

76-BXB3/WX

optional

76-BXB3/BV

standard

76-BXB3/BV2

standard

76-BXB3R/BV2

standard

76-BXB3/WV1

optional

76-BXB3R/WV1

optional

76-BXB3/BX

optional

76-BXB3R/WV

optional

76-BXB3R/WX

optional

76-BXB3R/BV

standard

76-BXB3R/BX

optional

0

10

20

30

40

50

60

70

80

90

100

90 mm  

(3.54") 

18 mm  

(0.71") 

0

10

20

30

40

50

60

70

80

90

100

0

10

20

30

40

50

60

70

80

90

100

Face plate scales and numbers

are shown close to actual size

Optional no charge substitute faceplates

for Temperature may be ordered scaled 

0 to 300°F or 0 to 150°C, Vertical or

Horizontal in Black or White background

See next page for clear self-adhesive caption sheets, each meter is shipped with standard or optional faceplates.

Summary of Contents for BX-B31

Page 1: ...of meters As shown on pages 4 to 5 See www texmate com for an up to date listing 31 segment AC DC powered modular compact bargraph 1 16 DIN 96 x 24mm case easily mounts in thin or thick panels up to 2...

Page 2: ...SP2 Relay Driver Circuit BX B31 with no setpoints BX B31 with 1 setpoint BX B31 with 2 setpoints 5A SP2 5 V 5 V 10A SP1 5 V 5A SP2 8 NO 1 9 NO 1 NO 2 10 11 12 with two 5 Amp Form A relays 14 15 5A 5 V...

Page 3: ...white on black face plate will be provided as standard Alternatively a face plate with black letters on a white background or a blank white or black face plate may be ordered as a no charge substitut...

Page 4: ...ion Special Options on last page ALL MODELS Symbols Indicate Module Compatibility Within Meter Families SOME MODELS MODEL SPECIFIC TIGER Family LEOPARD Family LYNX Family TIGER Family LEOPARD Family L...

Page 5: ...ormity error to NIST tables at 25 C J 2 C 1 digit typical J 4 F 1 digit maximum K 3 C 1 digit typical K 5 F 1 digit maximum LEOPARD LYNX TIGER IT01 LINEARITY ZERO SPAN 272D 24V Exc ON OFF 24V Exc DCmA...

Page 6: ...accept negative signals also and may be scaled for inputs from 50 to 100 of the range selected on the input signal conditioning module Wide range scaling in engineering units not requir ing offsets w...

Page 7: ...ting over range Signal Span is then scaled down by selecting the position of the SPAN RANGE Header and or the SPAN ADJUST Header which will reduce the input Signal Span to a percentage that the requir...

Page 8: ...r Custom Selectable Range CSR SETUP NRC to Set up Custom Selectable Range CSR INSTL Installation of Custom Selectable Range CSS SETUP NRC to Set up Custom Special Scaling CSS BR INSTL Installation of...

Reviews: