background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

Page 8

   BX-B31 Data Sheet (BX3)

   BX-B31 Data Sheet (BX3)

Ordering Information

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

OA____

OPTIONS / ACCESSORIES

RELAY OUTPUT

BX-B31

Add to the basic model number the order code suffix for each standard option required. The last suffix is to 

indicate how many different special options and or accessories that you may require to be included with this product. 

Ordering Example: BX-B31-VR-PS1-IA01-OA2, the 2 OA’s are, CR-CHANGE and a 75-DMT96X24

BASIC MODEL NUMBER

BX-B31  . . . 96x24mm, Lynx, 31 Segment Bargraph

Standard Options for this Model Number

Order Code Suffix

Description

DISPLAY

HG  . . .31 Segment Green LED Bargraph, Horizontal
HR . . . .31 Segment Red LED Bargraph, Horizontal
VG . . . .31 Segment Green LED Bargraph, Vertical

VR  . .31 Segment Red LED Bargraph, Vertical

POWER SUPPLY

PS1  . .85-265VAC/95-370VDC

PS2  . . .15-48VAC/10-72VDC

INPUT MODULES (Partial List. See www.texmate.com)

Unless otherwise specified Texmate will ship all modules pre calibrated with factory
preselected ranges and/or scalings as shown in 

BOLD

type.

IA01  . .AC-Volts Scaled RMS, 200/

600V

AC

IA02  . .AC-Volts Scaled RMS, 200mV/

2V

/20V AC

IA03  . .AC-mA Scaled RMS, 2/

20

/200mA AC

IA04  . .AC-Amps Scaled RMS, 

0-1 Amp AC (0-100.00)

IA05  . .AC-Amps Scaled RMS, 

0-5 Amp AC (0-100.00)

IA06  . .AC-Volts True RMS, 200/

600V

AC

IA07  . .AC-Volts True RMS, 200mV/

2V

/20V AC

IA08  . .AC-mA True RMS, 2/

20

/200mA AC

IA09  . .AC-Amps True RMS, 

0-1 Amp AC (0-100.00)

IA10  . .AC-Millivolt, Scaled RMS, 

100mV AC

IA11  . .AC-Amps True RMS, 

0-5 Amp AC (0-100.00)

IA12  . .AC-Millivolt, True RMS, 

100mV AC

ID01  . .DC-Volts,

2

/20/200V/Custom w/24V DC Exc

ID02  . .DC-Millivolt, 20/50/

100

/200mV DC w/24V DC Exc

ID03  . .DC-Milliamp, 2/

20

/200mA DC w/24V DC Exc

ID04  . .DC-Amps, 

5A DC

ID05  . .DC-Volts 

2

/20/200/Custom V DC w/Offset and 24V Exc

ID07  . .DC-Milliamp, 2/

20

/200mA DC w/Offset and 24V Exc  

ID09  . .DC-Amps, 

1A DC

IF02  . .Line Frequency, 50-500VAC, 199.9Hz, or optional 400Hz  
IGYZ*  . .Universal Direct Pressure

*View the IG- Ordering Code on page 5 to determine the value for Y & Z (IGAZ to IGKZ)

IP01  . .Process Loop, 

4-20mA(0-100.00)

 

IP02  . .Process Loop, 

4-20mA(0-100.00)

w/24VDC Exc

IP03  . .Process Input, 

1-5V DC(0-100.00)

w/Offset, 24V Exc

IPT1  . .Prototype Board for Custom Design
IR02  . . .3-Wire Potentiometer 1K

min (0-F.S.)

IR03  . . .Linear Potentiometer, 3-wire, 1K

min

IR04  . .Resistance 2K

IS04  . .Pressure Ext Exc., 20/2mV/V, 

4

/6–wire

IS05  . . .Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire
IS06  . . .Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire
IT03  . .RTD, 100

Pt. 2/

3

/4-wire

(-200 to 800°C)

IT04  . .RTD, 100

Pt. 2/

3

/4-wire 

(-200 to 1470°F)

IT05  . .RTD, 100

Pt. 2/

3

/4-wire 

(-190.0 to 199.0°F)

IT06  . .Thermocouple, J Type 

(0-1400 °F)

IT07  . .Thermocouple, K Type 

(0-1999°F)

IT08  . .Thermocouple, J Type 

(0-760 °C)

IT09  . .Thermocouple, K Type 

(0-1260°C)

IT14  . .RTD, 100

Pt. 2/

3/

4-wire 

(-199.0 to 199.0°C)

RELAY OUTPUT

R1  . . . .Single 5A Form A Relay

R2  . . . .Dual 5A Form a Relays
R11  . . .Single 10A Form C Relay
R16  . . .Single 10A Form C & Single 5A Form C Relays

Special Options and Accessories (OA’s) 

Part Number

Description

SPECIAL OPTIONS (Specify Input & Req. Reading)

CR-CHANGE  . . . .Range change from the standard input as shown in BOLD type 
CS-BAR  . . . . . . .Custom Scaling within any Stnd. or Custom Selectable Range
CSR-SETUP  . . . .NRC to Set-up Custom Selectable Range  
CSR-INSTL  . . . . .Installation of Custom Selectable Range  

CSS-SETUP  . . . .NRC to Set-up Custom Special Scaling  

CSS-BR/INSTL  . .Installation of custom special scaling of bargraph

ACCESSORIES  (Specify Serial # for Custom Artwork Installation)

75-DMT96X24  . . . . .Side Slide Brackets (2 pc) - extra set, extra strength
75-DBBZ96X24  . . . .Extra Black Bezel for 96x24mm Case
ART-FB-S/L/C  . . . . .NRC for artwork & set-up Faceplate/Desc/Co.Logo
ART-FB-S/L  . . . . . . .NRC for artwork & set-up Faceplate/Desc
ART-FB-001  . . . . . . .Install Custom Faceplate per meter - 1 color
93-PLUG2P-DP  . . . .Extra Screw Terminal Conn., 2 Pin Power Plug
93-PLUG2P-DR  . . . .Extra Screw Terminal Conn., 2 Pin Plug
93-PLUG3P-DR  . . . .Extra Screw Terminal Conn., 3 Pin Plug 
93-PLUG4P-DR  . . . .Extra Screw Terminal Conn., 4 Pin Plug
DN.CAS96X24L  . . . .Complete 96x24mm Case with bezel

OP-MCLP96X24 . . . .Screw Mounting Clips (2 pc) - to screw tighten slide brackets  

Many other options and accessories are available. See full price list for more details.

Prices subject to change without notice.

WARRANTY

Texmate warrants that its products are free from defects in material and workmanship under
normal use and service for a period of one year from date of shipment. Texmate’s obligations
under this warranty are limited to replacement or repair, at its option, at its factory, of any of the
products which shall, within the applicable period after shipment, be returned to Texmate’s facil-
ity, transportation charges pre-paid, and which are, after examination, disclosed to the satis-
faction of Texmate to be thus defective. The warranty shall not apply to any equipment which
shall have been repaired or altered, except by Texmate, or which shall have been subjected to
misuse, negligence, or accident. In no case shall Texmate’s liability exceed the original pur-
chase price. The aforementioned provisions do not extend the original warranty period of any
product which has been either repaired or replaced by Texmate.

USER’S RESPONSIBILITY

We are pleased to offer suggestions on the use of our various products either by way of print-
ed matter or through direct contact with our sales/application engineering staff. However, since
we have no control over the use of our products once they are shipped, NO WARRANTY
WHETHER OF MERCHANTABILITY, FITNESS FOR PURPOSE, OR OTHERWISE is made
beyond the repair, replacement, or refund of purchase price at the sole discretion of Texmate.
Users shall determine the suitability of the product for the intended application before using,
and the users assume all risk and liability whatsoever in connection therewith, regardless of any
of our suggestions or statements as to application or construction. In no event shall Texmate’s
liability, in law or otherwise, be in excess of the purchase price of the product.

Texmate cannot assume responsibility for any circuitry described. No circuit patent or software
licenses are implied. Texmate reserves the right to change circuitry, operating software, speci-
fications, and prices without notice at any time.

For product details visit www.texmate.com

Local Distributor Address

Tel: 1-760-598-9899 • USA 1-800-839-6283 • That’s 1-800-TEXMATE
Fax: 1-760-598-9828 • Email: [email protected] • Web: www.texmate.com 

Copyright © 2018 Texmate Inc. All Rights Reserved.

1934 Kellogg Ave. Carlsbad, CA 92008

Summary of Contents for BX-B31

Page 1: ...of meters As shown on pages 4 to 5 See www texmate com for an up to date listing 31 segment AC DC powered modular compact bargraph 1 16 DIN 96 x 24mm case easily mounts in thin or thick panels up to 2...

Page 2: ...SP2 Relay Driver Circuit BX B31 with no setpoints BX B31 with 1 setpoint BX B31 with 2 setpoints 5A SP2 5 V 5 V 10A SP1 5 V 5A SP2 8 NO 1 9 NO 1 NO 2 10 11 12 with two 5 Amp Form A relays 14 15 5A 5 V...

Page 3: ...white on black face plate will be provided as standard Alternatively a face plate with black letters on a white background or a blank white or black face plate may be ordered as a no charge substitut...

Page 4: ...ion Special Options on last page ALL MODELS Symbols Indicate Module Compatibility Within Meter Families SOME MODELS MODEL SPECIFIC TIGER Family LEOPARD Family LYNX Family TIGER Family LEOPARD Family L...

Page 5: ...ormity error to NIST tables at 25 C J 2 C 1 digit typical J 4 F 1 digit maximum K 3 C 1 digit typical K 5 F 1 digit maximum LEOPARD LYNX TIGER IT01 LINEARITY ZERO SPAN 272D 24V Exc ON OFF 24V Exc DCmA...

Page 6: ...accept negative signals also and may be scaled for inputs from 50 to 100 of the range selected on the input signal conditioning module Wide range scaling in engineering units not requir ing offsets w...

Page 7: ...ting over range Signal Span is then scaled down by selecting the position of the SPAN RANGE Header and or the SPAN ADJUST Header which will reduce the input Signal Span to a percentage that the requir...

Page 8: ...r Custom Selectable Range CSR SETUP NRC to Set up Custom Selectable Range CSR INSTL Installation of Custom Selectable Range CSS SETUP NRC to Set up Custom Special Scaling CSS BR INSTL Installation of...

Reviews: