Item 

no. 

Item name 

Qty. 

Description 

Picture 

conditions. Distance will be 
shorter in non-line of sight 
conditions) 

Cellular Antenna 

Plugged into the gateway in 
order to access the cellular 
network 

Wireless Gateway 
Power  
Wall Adaptor 

Powers the wireless gateway 

4 pin “Molex” 

Connector

AC 

Adaptor

SCC C Wall 
Adaptor 

This accessory is provided to 
quickly charge the SCC if 
internal energy storage is 
depleted  

Plugged into 

the SCC sensor 

connector

AC 

Adaptor

Magnet 

This accessory can be used to 
manually activate sampling of 
data from the sensor and 
transmission to the gateway, as 
opposed to waiting up to 30 
minutes for the next automatic 
transmission. This is done by A 
magnet touch the SCC (not used 
on a regular basis) 

10 

User account 
Activation to the 
sensor visualization 
service 

The system is already pre-
integrated with Sol-Chip Portal. 
Locate the account activation 
email to start the registration 
process. 

11 

Installation guide 

This document 

12 

Sol Chip SCC-S433 
Wireless Solar Tag 
product brief 

13 

Sol Chip Wireless 
Gateway user 
manual 

Summary of Contents for Sol Chip Comm Wireless Solar Tag System Kit

Page 1: ...157 Jaffa Street Amot Building Haifa Israel 35251 Fax 972 4 6228513 Tel 972 4 8216942...

Page 2: ...itors the following parameters soil moisture air temperature and air humidity and sends these parameters to the internet Cloud This real time actionable sensors data is an enabler of IOT applications...

Page 3: ...is controlled via the cable which connects to one of the SCCs Plugged into the ground Sensor cable Connector 3 Air Temperature and Humidity Sensor 1 The dual purpose sensor is controlled through the c...

Page 4: ...ernal energy storage is depleted Plugged into the SCC sensor connector AC Adaptor 9 Magnet 1 This accessory can be used to manually activate sampling of data from the sensor and transmission to the ga...

Page 5: ...a Street Amot Building Haifa Israel 35251 Fax 972 4 6228513 Tel 972 4 8216942 Item no Item name Qty Description Picture 14 Soil Moisture sensor data sheet 1 15 Air Temperature and humidity sensor data...

Page 6: ...SCCs are all weather IP 67 compliant hence can be placed outdoor e g in an agricultural field and operate in temperatures from 20C to 80C exposed to rain etc 3 The SCC solar panels need few hours of...

Page 7: ...a Connect the soil moisture sensor cable to the SCC 1 s sensor connector black Similarly connect the air temperature and humidity sensor cable to the second SCC 2 2 Place the sensors in the desired l...

Page 8: ...of sight path free of metal obstacle between antenna and gateway Both the gateway s and SCC s antennas should be installed in same vertical orientation f The SCC s energy storage are pre charged hence...

Page 9: ...lar A Red LED ON The Gateway is connected to the server OFF The Gateway is not connected to the server Cellular B Green LED Blinks quickly 2 times per second or ON search for cellular network Blinks s...

Page 10: ...il with an invitation to activate your account Look for the following email From Telit IoT Portal noreply devicewise com Subject line Welcome to the Sol Chip Portal powered by deviceWISE If you cannot...

Page 11: ...972 4 6228513 Tel 972 4 8216942 c Your account is now activated proceed to login d After login please review and agree to the general terms and conditions and privacy policy of the portal e After app...

Page 12: ...go to https solchip devicewise net and enter your login information If you forgot your password use the Recover account Reset password link to reset your password If you are still having trouble cont...

Page 13: ...d and is accessible for viewing by the user We are constantly updating our services always check the latest version of the user guide on our website at https solchip devicewise net Navigating sensor d...

Page 14: ...972 4 6228513 Tel 972 4 8216942 Sensor visualization service Below is an example of a Temperature sensor graph The user can set the time window to view historical data and horizontal zoom shorter time...