Texim Europe Sol Chip Comm Wireless Solar Tag System Kit Installation And Operating Manual Download Page 16

157 Jaffa Street, "Amot Building" Haifa Israel ,35251 Fax + (972) 4 6228513 . Tel + (972) 4 8216942

 

5. Check if there are metallic or other obstructions

between the SCC and the gateway; try to activate the
SCC by passing the magnet

6. Bring the SCC closer to the gateway; try to activate

the SCC by passing the magnet

7. The SCC internal energy storage might be depleted –

check latest record of the SCC energy storage voltage
level (in Sol Chip’s portal). If depleted, disconnect the
sensor and connect the SCC charger instead; charge
the SCC for 6 hours. Disconnect the SCC charger and
connect the sensor again. try to activate the SCC by
passing the magnet

8. If none of the above solves the problem, contact Sol

Chip support

Manually forcing a transmission of the SCC: 

If you want to get immediate reaction from the sensor, use the magnet to activate 
the SCC as follows: 

1. Bring the magnet close to the SCC at this point
2. “RF B” (Green) LED at the Wireless Gateway’s panel will blink once
3. You will see transmission at the web site within few seconds

Attention! 

Please familiarize yourself with the important safety related notes below: 

1. Carefully unpack the Demo kit. When unpacking, care should be taken to prevent dropping
2. One should be very careful while handling the SCC output ports. The sensor connector pins are

connected to the output of the internal energy storage and have a potential of ~3.3V. Shortening the
ports may discharge the internal rechargeable battery very quickly, while damaging the internal
circuitry

3. While the Wireless Gateway is operational, one should note that in order to avoid permanent

damage, neither cellular devices, nor SCC tags should be brought near the gateway’s immediate
surroundings (less than 20 centimeters)

4. The Wireless Gateway has limited lighting protection and it is the user’s responsibility to install

surge protection on the antenna and lighting protection near the gateway unit

5. The SCC-S433 contains a rechargeable battery. Whenever this unit is transported, the carrier’s

shipping constrains should be followed

6.

Do not open any of the kit components. Any damage created due to opening the components is not
under Sol Chip’s responsibility

Support 

Please contact us by email 

[email protected]

 

Summary of Contents for Sol Chip Comm Wireless Solar Tag System Kit

Page 1: ...157 Jaffa Street Amot Building Haifa Israel 35251 Fax 972 4 6228513 Tel 972 4 8216942...

Page 2: ...itors the following parameters soil moisture air temperature and air humidity and sends these parameters to the internet Cloud This real time actionable sensors data is an enabler of IOT applications...

Page 3: ...is controlled via the cable which connects to one of the SCCs Plugged into the ground Sensor cable Connector 3 Air Temperature and Humidity Sensor 1 The dual purpose sensor is controlled through the c...

Page 4: ...ernal energy storage is depleted Plugged into the SCC sensor connector AC Adaptor 9 Magnet 1 This accessory can be used to manually activate sampling of data from the sensor and transmission to the ga...

Page 5: ...a Street Amot Building Haifa Israel 35251 Fax 972 4 6228513 Tel 972 4 8216942 Item no Item name Qty Description Picture 14 Soil Moisture sensor data sheet 1 15 Air Temperature and humidity sensor data...

Page 6: ...SCCs are all weather IP 67 compliant hence can be placed outdoor e g in an agricultural field and operate in temperatures from 20C to 80C exposed to rain etc 3 The SCC solar panels need few hours of...

Page 7: ...a Connect the soil moisture sensor cable to the SCC 1 s sensor connector black Similarly connect the air temperature and humidity sensor cable to the second SCC 2 2 Place the sensors in the desired l...

Page 8: ...of sight path free of metal obstacle between antenna and gateway Both the gateway s and SCC s antennas should be installed in same vertical orientation f The SCC s energy storage are pre charged hence...

Page 9: ...lar A Red LED ON The Gateway is connected to the server OFF The Gateway is not connected to the server Cellular B Green LED Blinks quickly 2 times per second or ON search for cellular network Blinks s...

Page 10: ...il with an invitation to activate your account Look for the following email From Telit IoT Portal noreply devicewise com Subject line Welcome to the Sol Chip Portal powered by deviceWISE If you cannot...

Page 11: ...972 4 6228513 Tel 972 4 8216942 c Your account is now activated proceed to login d After login please review and agree to the general terms and conditions and privacy policy of the portal e After app...

Page 12: ...go to https solchip devicewise net and enter your login information If you forgot your password use the Recover account Reset password link to reset your password If you are still having trouble cont...

Page 13: ...d and is accessible for viewing by the user We are constantly updating our services always check the latest version of the user guide on our website at https solchip devicewise net Navigating sensor d...

Page 14: ...972 4 6228513 Tel 972 4 8216942 Sensor visualization service Below is an example of a Temperature sensor graph The user can set the time window to view historical data and horizontal zoom shorter time...

Page 15: ...gateway location to a place with proper coverage 2 Note that if you observe a cellular signal in your mobile device it may be that the SIM in the gateway is configured to roam to a different network...

Page 16: ...n few seconds Attention Please familiarize yourself with the important safety related notes below 1 Carefully unpack the Demo kit When unpacking care should be taken to prevent dropping 2 One should b...

Page 17: ...0 26 30 F 45 88 20 26 39 E nordic texim europe com Zuiderlaan 14 bus 10 B 1731 Zellik T 32 0 2 462 01 00 F 32 0 2 462 01 25 E belgium texim europe com Martin Kollar Strasse 9 D 81829 M nchen T 49 0 89...

Reviews: