Texecom Prestige Orbit DT Installation Manual Download Page 2

1

INS483

•  A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package 
and a microwave sensor. Both sensors have to trigger before the detector signals an alarm. This high 
precision, very reliable presence detector has been designed for use within CCTV installations.
Programmable parameters include a pulse count feature and a choice of detection ranges from 10 to 
30 metres.
•  The integral dual axis tilt sensor allows 180˚ of pan and 90˚ tilt.  This increases the speed of the 
outdoor installation and provides incredibly accurate aiming of the detection pattern. The electronics 
module is acrylic coated for additional component stability.  It is encased in an ABS housing with a 
UV stabilised translucent front cover ensuring the sensor is impervious to and unaffected by weather 
conditions. Additionally the combination of precision electronics, digital white light filter and double 
shielding eliminates false alarms from the sun and other visible light sources.
• The Prestige Orbit design gives a neat and professional appearance with no visible indication of the 
orientation of the detector head, and totally hides the wiring.

 

Introduction

 

Quick Installation Guide

Apply supply voltage to the unit, the blue LED flashes 3 times.

The detector takes approximately 2-3 minutes to settle.

The walk test LED is factory set to OFF. Pressing the program button once will enable the walk test LED 
for 5 minutes.

THE FRONT COVER MUST BE FITTED WHEN WALK TESTING.

FACTORY SETTINGS ARE:-
1 RANGE 30 METRES
2 PULSE COUNT 1
3 LED OFF

When enabled the 

Prestige Orbit DT 

has three LED indicators.

Green - Microwave detection
Red - Both PIRs detection
Blue - Alarm output, both PIRs and microwave detection

Summary of Contents for Prestige Orbit DT

Page 1: ...Prestige Orbit QD DT Installation Manual INS483...

Page 2: ...ing the sensor is impervious to and unaffected by weather conditions Additionally the combination of precision electronics digital white light filter and double shielding eliminates false alarms from...

Page 3: ...fts out of the location slot See fig 3 1 Mounting the Unit 4 3 Feed standard 8 core alarm cable into the cable entry bare the wires and connect to the removable terminal block as shown in fig 7 Screw...

Page 4: ...ut 1 Multiplexer PTZ Dome DVR etc 0V Supply 12VDC Supply 5 6 4 Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern...

Page 5: ...as trees shrubs ponds boiler flues and animals should be considered when positioning the detector The detector module is fitted with two sliding shutters to reduce the detection angle An additional se...

Page 6: ...ea being covered Use portions of the self adhesive silver mask supplied to the rear smooth side of the lens as shown in the diagrams below Always replace the lens the correct way up to ensure exact be...

Page 7: ...to be changed i e once for range twice for pulse count three times for LED 2 Wait four seconds until the blue LED indicator goes off 3 The indicator will then flash out the existing setting 4 To chan...

Page 8: ...be saved in the setup procedure when using the Walk Tester and it s use is highly recommended If you have difficulty in aligning the detector and you have issues with either short or long ranging a Wa...

Page 9: ...walk test mode by pressing the programme button once Fig 11 The Prestige Orbit s clear LED will then flash out its current settings Wait for the flashing sequence to finish The Prestige Orbit is now...

Page 10: ...z 10 525GHz 10 587GHz Albania Argentina Australia Austria Belgium Brazil Croatia Czech Republic Denmark France Germany Greece Holland Hungary Iceland Indonesia Italy Latvia Lithuania Malta Norway Port...

Page 11: ...e 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds Power Input 9 to 15 VDC Current 15mA 12V nominal Pulse Count 1 2 Temp C...

Page 12: ...state magnetically immune No 1 N OPEN Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA...

Reviews: