Detection Area

Programmable between 10 & 30 metres.

Coverage 

10 - 70 degrees detection angle, 30 m x 30 m coverage max.

Adjustment 

180 degree pan + 90 degree tilt.

Fresnel Lens 

28 zones for each pyro pair, which can be masked with the curtain sliders.

Customised Optics

Double silicon shielded quad element eliminates 50,000 lux of white light.

Outputs

Silent solid state magnetically immune.

No.1 - N/OPEN

Volt free relay signal contact 24V

AC/DC

 @ 50mA with an integral 25R series 

resistor. Alarm time 5 seconds.

No.2 - N/CLOSED

Volt free relay signal contact 24V

AC/DC

 @ 50mA with an integral 25R series 

resistor. Alarm time 5 seconds.

Power Input

9 to 15 V

DC

.

Current

8mA (12V nominal).

Pulse Count

1 - 2.

Temp. Compensation

Digital sensitivity adjustment.

Control

Digital microprocessor - non volatile memory.

Walk Test

Output test mode with LED indication.

Operating Temp.

-20 to + 55˚C. Conformally coated electronics for increased stability.

Housing

ABS.

Protection Rating

lP 55.

Dimensions

141 x 165.5 x 109 mm.

Weight

275 grams.

Mounting Height

Variable up to 6 metres - optimum height 3 metres.

Cable < 200m

Utilising all three outputs (incl. tamper) – 8 core 7/0.2mm.

Cable < 500m

Utilising all three outputs (incl. tamper) – 8 core 16/0.2mm.

11.  Technical Specifications - Prestige Orbit QD

Summary of Contents for Prestige Orbit DT

Page 1: ...Prestige Orbit QD DT Installation Manual INS483...

Page 2: ...ing the sensor is impervious to and unaffected by weather conditions Additionally the combination of precision electronics digital white light filter and double shielding eliminates false alarms from...

Page 3: ...fts out of the location slot See fig 3 1 Mounting the Unit 4 3 Feed standard 8 core alarm cable into the cable entry bare the wires and connect to the removable terminal block as shown in fig 7 Screw...

Page 4: ...ut 1 Multiplexer PTZ Dome DVR etc 0V Supply 12VDC Supply 5 6 4 Always ensure when replacing the electronics module that the LED is facing forward so as to ensure correct alignment of the beam pattern...

Page 5: ...as trees shrubs ponds boiler flues and animals should be considered when positioning the detector The detector module is fitted with two sliding shutters to reduce the detection angle An additional se...

Page 6: ...ea being covered Use portions of the self adhesive silver mask supplied to the rear smooth side of the lens as shown in the diagrams below Always replace the lens the correct way up to ensure exact be...

Page 7: ...to be changed i e once for range twice for pulse count three times for LED 2 Wait four seconds until the blue LED indicator goes off 3 The indicator will then flash out the existing setting 4 To chan...

Page 8: ...be saved in the setup procedure when using the Walk Tester and it s use is highly recommended If you have difficulty in aligning the detector and you have issues with either short or long ranging a Wa...

Page 9: ...walk test mode by pressing the programme button once Fig 11 The Prestige Orbit s clear LED will then flash out its current settings Wait for the flashing sequence to finish The Prestige Orbit is now...

Page 10: ...z 10 525GHz 10 587GHz Albania Argentina Australia Austria Belgium Brazil Croatia Czech Republic Denmark France Germany Greece Holland Hungary Iceland Indonesia Italy Latvia Lithuania Malta Norway Port...

Page 11: ...e 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds Power Input 9 to 15 VDC Current 15mA 12V nominal Pulse Count 1 2 Temp C...

Page 12: ...state magnetically immune No 1 N OPEN Volt free relay signal contact 24VAC DC 50mA with an integral 25R series resistor Alarm time 5 seconds No 2 N CLOSED Volt free relay signal contact 24VAC DC 50mA...

Reviews: