8.
Option Definitions
PULSE COUNT
This is the number of times the unit has to detect on both of its sensors before signalling an output.
LED MONITOR
LED Off - LED disabled.
LED On - LED signals a detection.
N/OPEN & N/CLOSED
These are magnetically immune volt free relay contacts used to trigger alarm inputs on connected
equipment. The contacts are rated at a maximum of 24V
AC/DC
@ 50 mA.
ACCESSORIES
Texecom is able to supply the following accessories to aid installations:
Pole mount bracket available on request.
(JAH-0001) Prestige Orbit Walk Tester.
INS483
8
7.
Using the Walk Tester
Remove the cover from the Prestige Orbit housing by
loosening the locking screw at the bottom of the detector.
This will allow access to the programming button shown
in
Fig.11
(and to also to show the location of the blue IR
emitting LED).
Place the Prestige Orbit into ‘walk test’ mode by pressing
the programme button once
(Fig.11)
. The Prestige Orbit’s
clear LED will then flash out its current settings. Wait for
the flashing sequence to finish. The Prestige Orbit is now
in walk test mode and will remain in that state for five
minutes after the last detection, whereafter it will revert to
normal mode. The walk test can be cancelled at anytime by
pressing the programme button twice.
Replace the Prestige Orbit cover and place the Walk Tester in the metal holder.
Slightly loosen the stainless steel screw on the bottom of the Prestige Orbit, just
enough so that the drilled tab on the Walk Tester bracket can slide around the
screw thread. Then gently tighten the screw to hold the Walk Tester and holder in
place. Turn the Walk Tester on.
The Walk Tester will illuminate and sound every time the Prestige Orbit is
activated.
When finished testing, turn off the Walk Tester and remove it and the holder from
the Prestige Orbit. Tighten the screw on the base of the Prestige Orbit. The external
detector is now ready.