Test Results
4-3
Test Results
Figure 4–3. No Load – Full Load (500 mA) Transition With C
O
= 33
µ
F POSCAP
–
Maximum Transient Droop Voltage
The maximum transient droop voltage is 56 mV.
Figure 4–4. Timing When SEQUENCE = Low
V
IN1 =
V
IN2
at 5V and both V
OUT1
(CH1) and V
OUT2
(CH2) have no load. EN
is pulsed with a fast pulse. V
OUT1
powers up before V
OUT2
when SEQUENCE
= low. PG_1 (CH3), tied to MR1, goes high when V
OUT1
reaches 95% of
regulated voltage.