FUNC_PAD_CONTROL Registers
110
SLVUAH1C – June 2015 – Revised April 2017
Copyright © 2015–2017, Texas Instruments Incorporated
Register Descriptions
3.9.4 PU_PD_INPUT_CTRL3 Register (Address = 1F6h) [reset = 44h]
PU_PD_INPUT_CTRL3 is shown in
and described in
.
Return to
Pull-up Pull-down control register #3
RESET register domain: HWRST
Note: It is user responsibility to take care about the pull-up/pull-down selections versus the IO direction
and type (Open drain / Push-Pull)
Figure 3-93. PU_PD_INPUT_CTRL3 Register
7
6
5
4
3
2
1
0
RESERVED
SYNCDCDC_P
D
RESERVED
RESERVED
RESERVED
POWERHOLD_
PD
RESERVED
RESERVED
R-0h
R/W-1h
R-0h
R-0h
R-0h
R/W-1h
R-0h
R-0h
Table 3-102. PU_PD_INPUT_CTRL3 Register Field Descriptions
Bit
Field
Type
Reset
Description
7
RESERVED
R
0h
-
6
SYNCDCDC_PD
R/W
1h
Secondary function of GPIO_3
0: Pull-down not enabled
1: Pull-down enabled
5
RESERVED
R
0h
4
RESERVED
R
0h
3
RESERVED
R
0h
2
POWERHOLD_PD
R/W
1h
Secondary function of GPIO_5
0: Pull-down not enabled
1: Pull-down enabled (default)
1
RESERVED
R
0h
0
RESERVED
R
0h