3.4 Load Transient and Loop Response
and
show the response to load transients for both designs. The current step is from 0.75
A to 2.25 A and the current step slew rate is 1 A/µs. An electronic load is used to provide a DC 0.75-A load and
the load transient circuit on the EVM is used to provide a 1.5-A step. The VOUT voltage is measured using TP10
for U1 and TP29 for U2.
When using the load transient circuit included on the TPS543320EVM, slowly increase amplitude of function
generator for desired load step amplitude then vary the rise and fall times for the desired slew rate. The current
for the load step can be sensed with the ISNS test point. The default resistors on the EVM provide a gain of 10
A/V. With this gain, a 1.5-A step will result in 150-mV at the ISNS test point.
Note
To use the load transient circuit with U1, move R27 to R28.
show the loop characteristics for both designs. Gain and phase plots are shown for
V
IN
voltage of 12 V and a 0.72-Ω or 1.32-Ω resistive load.
Figure 3-9. U1 Transient Response
Figure 3-10. U2 Transient Response
Frequency (Hz)
Ga
in (dB)
Phase (
q
)
100
1000
10000
100000
1000000
-40
-120
-20
-60
0
0
20
60
40
120
60
180
Figure 3-11. U1 Bode Plot
Frequency (Hz)
Ga
in (dB)
Phase (
q
)
100
1000
10000
100000
1000000
-80
-240
-60
-180
-40
-120
-20
-60
0
0
20
60
40
120
60
180
Figure 3-12. U2 Bode Plot
Test Setup and Results
14
TPS543320 SWIFT™ Step-Down Converter Evaluation Module User's Guide
SLVUC07A – DECEMBER 2020 – REVISED MAY 2021
Copyright © 2021 Texas Instruments Incorporated