VOUT
SS
t - Time - 2 ms/div
Figure 2-10. TPS54232EVM-415 Start-Up Relative to Enable
2.10 Eco-mode Operation
At light load currents, the TPS54232 is designed to operate in pulse skipping Eco-mode. When the peak inductor
current is lower than 100 mA typical, the device enters Eco-mode.
shows Eco-mode operation, channel 1(C1) shows the output voltage while channel 2(C2) shows the
switching node (PH).
Figure 2-11. TPS54232EVM-415 Eco-mode Operation
Test Setup and Results
SLVU277A – JANUARY 2009 – REVISED OCTOBER 2021
TPS54232 Step-Down Converter Evaluation Module User's Guide
9
Copyright © 2021 Texas Instruments Incorporated