background image

www.ti.com

5

8.

Limitations on Damages and Liability:

8.1

General Limitations

. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,

INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS OR THE USE OF THE EVMS , REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, COST OF REMOVAL OR
REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, RETESTING,
OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS, LOSS OF SAVINGS, LOSS OF
USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL BE BROUGHT AGAINST TI
MORE THAN TWELVE (12) MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS
OCCURRED.

8.2

Specific Limitations.

IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY USE OF AN EVM PROVIDED

HEREUNDER, INCLUDING FROM ANY WARRANTY, INDEMITY OR OTHER OBLIGATION ARISING OUT OF OR IN
CONNECTION WITH THESE TERMS, , EXCEED THE TOTAL AMOUNT PAID TO TI BY USER FOR THE PARTICULAR
EVM(S) AT ISSUE DURING THE PRIOR TWELVE (12) MONTHS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE
CLAIMED. THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT.

9.

Return Policy.

Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)

will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.

10.

Governing Law:

These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,

without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.

Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265

Copyright © 2019, Texas Instruments Incorporated

Summary of Contents for TPS54232EVM-415

Page 1: ...n 6 Figure 2 5 TPS54232EVM 415 Transient Response 6 Figure 2 6 TPS54232EVM 415 Loop Response 7 Figure 2 7 TPS54232EVM 415 Output Ripple 7 Figure 2 8 TPS54232EVM 415 Input Ripple 8 Figure 2 9 TPS54232E...

Page 2: ...absolute maximum input voltage is 30 V for the TPS54232EVM 415 Table 1 1 Input Voltage and Output Current Summary EVM INPUT VOLTAGE RANGE OUTPUT CURRENT RANGE TPS54232EVM 415 VIN 5 V to 15 V 0 A to 2...

Page 3: ...ection describes how to properly connect set up and use the TPS54232EVM 415 evaluation module The section also includes test results typical for the evaluation module and covers efficiency output volt...

Page 4: ...y of this EVM peaks at a load current of about 0 5 A with VIN 5 V and then decreases as the load current increases towards full load Figure 2 1 shows the efficiency for the TPS54232EVM 415 at an ambie...

Page 5: ...Load Regulation The load regulation for the TPS54232EVM 415 is shown in Figure 2 3 0 1 0 08 0 06 0 04 0 02 0 0 02 0 04 0 06 0 08 0 1 0 0 2 0 4 0 6 0 8 1 1 2 1 4 1 6 1 8 2 I Output Current A O Output...

Page 6: ...M 415 response to load transients is shown in Figure 2 5 The current step is from 25 to 75 of maximum rated load at 15V input Total peak to peak voltage variation is as shown including ripple and nois...

Page 7: ...M Figure 2 6 TPS54232EVM 415 Loop Response 2 7 Output Voltage Ripple The TPS54232EVM 415 output voltage ripple is shown in Figure 2 7 The output current is the rated full load of 2 A and VIN 15 V The...

Page 8: ...ow start voltage In Figure 2 10 the input voltage is initially applied and the output is inhibited by using a jumper at J2 to tie EN to GND When the jumper is removed EN is released When the EN voltag...

Page 9: ...r than 100 mA typical the device enters Eco mode Figure 2 11 shows Eco mode operation channel 1 C1 shows the output voltage while channel 2 C2 shows the switching node PH Figure 2 11 TPS54232EVM 415 E...

Page 10: ...the board including ten vias directly under the TPS54232 device to provide a thermal path from the top side ground plane to the bottom side ground plane The input decoupling capacitor C1 C2 is not use...

Page 11: ...printed circuit board area for the components used in this design is 0 44 in2 This area does not include test point or connectors www ti com Board Layout SLVU277A JANUARY 2009 REVISED OCTOBER 2021 Su...

Page 12: ...ematic Figure 4 1 is the schematic for the TPS54232EVM 415 Figure 4 1 TPS54232EVM 415 Schematic Schematic and Bill of Materials www ti com 12 TPS54232 Step Down Converter Evaluation Module User s Guid...

Page 13: ...ft 1 R1 150 k Resistor Chip 1 16W 1 0603 Std Std 1 R2 48 7 k Resistor Chip 1 16W 1 0603 Std Std 1 R3 17 4 k Resistor Chip 1 16W 1 0603 Std Std 1 R4 0 Resistor Chip 1 16W 1 0603 Std Std 1 R5 10 2 k Res...

Page 14: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Page 15: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Page 16: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Page 17: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Page 18: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Page 19: ...change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of thes...

Reviews: