ASCII Protocol - Reference Guide
May ’00
3.2
Possible Programming Responses in MPT Mode (K1)
This section illustrates the response formats sent out by MPTs after an attempt is
made to program it.
a. A complete transponder protocol could be detected by the TIRIS reader
Reader --> PC:
abc dd eeee ffffffffffffffff<CR><LF>
Standard TIRIS output
format (display in decimal
format)
abc dd fffffffffffffff<CR><LF>
If the FORMAT command
(display in hexadecimal
format) was used
b. An incomplete transponder protocol was detected by the TIRIS reader
Reader --> PC:
ab<CR><LF>
Element
Description
Range
a
antenna that has attempted to program the transponder
1, 2
b
programming status
0, 1, 3, 4, 5, 6, 7
0:
programming was executed and the
comparison between read and written data was
O.K.
1:
programming was executed but the comparison
between read and written data was not equal
2:
see 3.2.b
3:
programming was disabled because the
programming voltage was too low
4:
programming was not executed because there
was an attempt to program a locked page
5:
page to be programmed is not available
6:
programming not reliable
7:
special data
c
transponder type
M (MPT)
d
specifies the transponder page that was read after an
attempt to program that page
01 to 17
dec
respectively 01 to 11
hex
e
read application number after an attempt to program a
transponder
0 to 4095
dec
f
identification number that was read after an attempt to
program a transponder (e and f together)
0 to 4503599627370495
dec
Respectively 0 to FFFFFFFFFFFF
hex
Element
Description
Range
a
antenna that has attempted to program a transponder
1, 2
b
programming status
2:No transponder response detected