1
PBIASLITEPWRDNZ0
Input Signal Referenced to VDD2. Software has to keep
RW
0x0
this bit at 0b0 when SDMMC1_VDDS is ramping up
0b0 => SDMMC1_VDDS ramping up
0b1 => SDMMC1_VDDS stable
0
PBIASLITEVMODE0
SDMMC1_VDDS voltage level information control from
RW
0x1
software
0b0 => SDMMC1_VDDS = 1.8 V
0b1 => SDMMC1_VDDS = 3.0 V
Table 13-237. Register Call Summary for Register CONTROL_PBIAS_LITE
SCM Functional Description
•
Extended-Drain I/O Pin and PBIAS Cells
:
•
:
SCM Programming Model
•
Extended-Drain I/Os and PBIAS Cells Programming Guide
[4] [5] [6] [7] [8] [9] [10] [11] [12]
•
:
•
Speed Control and Voltage Supply State
:
SCM Register Manual
•
:
Table 13-238. CONTROL_TEMP_SENSOR
Address Offset
0x0000 02B4
Physical Address
0x4800 2524
Instance
GENERAL
Description
temperature sensor register
Type
RW
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
TEMP
SOC
EOCZ
CONTCONV
Bits
Field Name
Description
Type
Reset
31:11
RESERVED
Read returns reset value.
R
0x0
10
CONTCONV
VDD level digital inputs. When high the ADC is in
RW
0x0
continuous conversion mode
0 : ADC Single Conversion Mode;
1 : ADC Continuous Conversion Mode
9
SOC
ADC Start of Conversion. A transition to high starts a new
RW
0x0
ADC conversion cycle
8
EOCZ
ADC End of Conversion. Active low, when CTRL_
R
0x0
TEMP[7:0] is valid
7:0
TEMP
Temperature data from the ADC. Valid if EOCZ is low
R
0x0
Table 13-239. Register Call Summary for Register CONTROL_TEMP_SENSOR
SCM Functional Description
•
Band Gap Voltage and Temperature Sensor
•
Single Conversion Mode (CONTCONV = 0)
•
Continuous Conversion Mode (CONTCONV = 1)
:
•
:
•
Temperature Sensor Control Register
: