Public Version
SCM Register Manual
www.ti.com
Bits
Field Name
Description
Type
Reset
31:24
RESERVED
Read returns reset value.
R
0x00000000
23:0
FUSE_OPP130_VDD1
SmartReflex Ntarget value for OPP130
R
0x–
(1)
(1)
Register reset value undefined; differs between devices.
Table 13-135. Register Call Summary for Register CONTROL_FUSE_OPP130_VDD1
SCM Register Manual
•
:
Table 13-136. CONTROL_FUSE_OPP100_2_VDD2
Address Offset
0x0000 0124
Physical Address
0x4800 2394
Instance
GENERAL
Description
Standard fuse OPP100 VDD2 [23:0]
Type
R
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
FUSE_OPP100_2 VDD2
Bits
Field Name
Description
Type
Reset
31:24
RESERVED
Read returns reset value.
R
0x00000000
23:0
FUSE_OPP100_2 VDD2
SmartReflex Ntarget value for OPP100 VDD2 with SGX
R
0x–
running at 266 MHz
(1)
(1)
(1) This N-target is blown only for the OMAP3630-1200 device.
Table 13-137. Register Call Summary for Register CONTROL_FUSE_OPP100_2_VDD2
SCM Register Manual
•
:
Table 13-138. CONTROL_FUSE_OPP50_VDD2
Address Offset
0x0000 0128
Physical Address
0x4800 2398
Instance
GENERAL
Description
Standard fuse OPP50 VDD2 [23:0]
Type
R
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
FUSE_OPP50_VDD2
Bits
Field Name
Description
Type
Reset
31:24
RESERVED
Read returns reset value.
R
0x00000000
23:0
FUSE_OPP50_VDD2
SmartReflex Ntarget value for OPP50 VDD2
R
0x–
(1)
(1)
Register reset value undefined; differs between devices.
Table 13-139. Register Call Summary for Register CONTROL_FUSE_OPP50_VDD2
SCM Register Manual
•
:
2592
System Control Module
SWPU177N – December 2009 – Revised November 2010
Copyright © 2009–2010, Texas Instruments Incorporated