electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
wake-up LPM3
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
f = 1 MHz
6
t
d(LPM3)
Delay time
f = 2 MHz
V
CC
= 3 V
6
μ
s
t
d(LPM3)
Delay time
f = 3 MHz
V
CC
3 V
6
μ
s
RAM (see Note 1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VRAMh
CPU halted (see Note 1)
1.6
V
NOTE 1: This parameter defines the minimum supply voltage when the data in the program memory RAM remain unchanged. No program
execution should take place during this supply voltage condition.
LCD
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
(33)
Voltage at R33
2.5
V
CC
+0.2
V
(23)
Analog voltage
Voltage at R23
V
3 V
(V
33
−V
03
)
×
2/3 + V
03
V
V
(13)
Analog voltage
Voltage at R13
V
CC
= 3 V
(V
(33)
−V
(03)
)
×
1/3 + V
(03)
V
V
(33) −
V
(03)
Voltage at R33/R03
2.5
V
CC
+0.2
I
(R03)
R03 = V
SS
No load at all
±
20
I
(R13)
Input leakage
R13 = V
CC
/3
segment and
common lines
±
20
nA
I
(R23)
p
g
R23 = 2
×
V
CC
/3
common lines,
V
CC
= 3 V
±
20
V
(Sxx0)
V
(03)
V
(03)
− 0.1
V
(Sxx1)
Segment line
I
3 A
V
3 V
V
(13)
V
(13)
− 0.1
V
V
(Sxx2)
Segment line
voltage
I
(Sxx)
= −3
μ
A,
V
CC
= 3 V
V(
23)
V
(23)
− 0.1
V
V
(Sxx3)
V(
33)
V
(33)
+ 0.1
USART0 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN
NOM
MAX
UNIT
t
(
τ
)
USART0: deglitch time
V
CC
= 3 V, SYNC = 0, UART mode
150
280
500
ns
NOTE 1: The signal applied to the USART0 receive signal/terminal (URXD0) should meet the timing requirements of t
(τ
)
to ensure that the URXS
flip-flop is set. The URXS flip-flop is set with negative pulses meeting the minimum-timing condition of t
(τ
)
. The operating conditions to
set the flag must be met independently from this timing constraint. The deglitch circuitry is active only on negative transitions on the
URXD0 line.
POR brownout, reset (see Notes 1 and 2)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
t
d(BOR)
2000
μ
s
V
CC(start)
dV
CC
/dt
≤
3 V/s (see Figure 6)
0.7
×
V
(B_IT−)
V
V
(B_IT−)
Brownout
dV
CC
/dt
≤
3 V/s (see Figure 6, Figure 7, and Figure 8)
1.71
V
V
hys(B_IT−)
Brownout
dV
CC
/dt
≤
3 V/s (see Figure 6)
70
130
180
mV
t
(reset)
Pulse length needed at RST/NMI pin to accepted reset internally,
V
CC
= 3 V
2
μ
s
NOTES:
1. The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level
V
(B_IT−)
+ V
hys(B_IT−)
is
≤
1.8 V.
2. During power up, the CPU begins code execution following a period of t
d(BOR)
after
V
CC
= V
(B_IT−)
+ V
hys(B_IT−)
.
The default FLL+ settings must not be changed until V
CC
≥
V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired
operating frequency. See the
MSP430x4xx Family User’s Guide
(SLAU056) for more information on the brownout/SVS circuit.