![Texas Instruments MSP430F4132IPM Manual Download Page 50](http://html1.mh-extra.com/html/texas-instruments/msp430f4132ipm/msp430f4132ipm_manual_1095506050.webp)
MSP430F41x2
MIXED SIGNAL MICROCONTROLLER
SLAS648E -- APRIL 2009 -- REVISED MARCH 2011
50
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
JTAG fuse (see Note 1)
PARAMETER
TEST
CONDITIONS
V
CC
MIN
MAX
UNIT
V
CC(FB)
Supply voltage during fuse-blow condition
T
A
= 25
C
2.5
V
V
FB
Voltage level on TDI/TCLK for fuse-blow
6
7
V
I
FB
Supply current into TDI/TCLK during fuse blow
100
mA
t
FB
Time to blow fuse
1
ms
NOTES: 1. Once the fuse is blown, no further access to the MSP430 JTAG/Test and emulation features is possible. The JTAG block is switched
to bypass mode.