Embedded Metering Library API
5.5.3.2.12 DEFAULT_EMI_FILTER_CAP_UF_A
EMI filter capacitance in units of 1/64 µF, Maximum 1023 (15.984375 µF)
Putting value greater than 0x8000 will result in no EMI filter compensation done
5.5.3.2.13 DEFAULT_WIRE_RESISTANCE_A
Estimate wire resistance in units of 1/256
Ω
, Maximum 255 (0.99609375
Ω
)
5.5.3.2.14 METER_NAME
Defines the name of the meter as reported by HOST_CMD_GET_METE_NAME and is defined as in the
provided example code "MSP430I2040SUBMETEREVM "
5.5.3.2.15 METER_SOFTWARE_VERSION
Defines the software version of the meter as reported by HOST_CMD_GET_METE_VER
5.5.3.2.16 METER_HARDWARE_VERSION
Defines the hardware version of the meter as reported by HOST_CMD_GET_METE_VER
5.5.3.2.17 METER_METROLOGY_VERSION
Defines the Metrology library version of the meter as reported by HOST_CMD_GET_METE_VER
5.5.3.2.18 METER_PROTOCOL_VERSION
Defines the Protocol version of the meter as reported by HOST_CMD_GET_METE_VER