Commands
4.3.14 HOST_CMD_GET_CALIBRATION_EXTRAS
This command reads the extra calibration value from the EVM
4.3.14.1 Command Format
HOST_CMD_GET_CALIBRATION_EXTRAS
Command
Respond
LEN
2
10
Offset
Width
Data
Offset
Width
Data
CMDH
0
U8
0xDA
0
U8
0xDA
CMDL
1
U8
0x00
1
U8
0x80
2
U16
Calibration status
4
U16
Intercept temperature
6
U16
Temperature intercept
8
U16
Temperature slope / degree
32
Serial Communication Commands
SLAU587 – August 2014
Copyright © 2014, Texas Instruments Incorporated