Recommended Timing for the Serial Control Bus
Over 3.3V supply and temperature ranges unless otherwise specified. (
Symbol
Parameter
Conditions
Min
Typ
Max
Units
f
SCL
SCL Clock Frequency
Standard Mode
0
100
kHz
Fast Mode
0
400
kHz
t
LOW
SCL Low Period
Standard Mode
4.7
µs
Fast Mode
1.3
µs
t
HIGH
SCL High Period
Standard Mode
4.0
µs
Fast Mode
0.6
µs
t
HD;STA
Hold time for a start or a
repeated start condition
Standard Mode
4.0
µs
Fast Mode
0.6
µs
t
SU:STA
Set Up time for a start or a
repeated start condition
Standard Mode
4.7
µs
Fast Mode
0.6
µs
t
HD;DAT
Data Hold Time
Standard Mode
0
3.45
µs
Fast Mode
0
0.9
µs
t
SU;DAT
Data Set Up Time
Standard Mode
250
ns
Fast Mode
100
ns
t
SU;STO
Set Up Time for STOP
Condition
Standard Mode
4.0
µs
Fast Mode
0.6
µs
t
BUF
Bus Free Time
Between STOP and START
Standard Mode
4.7
µs
Fast Mode
1.3
µs
t
r
SCL & SDA Rise Time,
Standard Mode
1000
ns
Fast Mode
300
ns
t
f
SCL & SDA Fall Time,
Standard Mode
300
ns
Fast mode
300
ns
DC and AC Serial Control Bus Characteristics
Over 3.3V supply and temperature ranges unless otherwise specified. (
Symbol
Parameter
Conditions
Min
Typ
Max
Units
V
IH
Input High Level
SDA and SCL
0.7*
V
DDIO
V
DD33
V
V
IL
Input Low Level Voltage
SDA and SCL
GND
0.3*
V
DD33
V
V
HY
Input Hysteresis
>50
mV
V
OL
SDA or SCL, IOL = 1.25mA
0
0.36
V
I
in
SDA or SCL, Vin = V
DDIO
or GND
-10
+10
µA
t
R
SDA RiseTime – READ
SDA, RPU = 10k
Ω
, Cb
≤
400pF,
430
ns
t
F
SDA Fall Time – READ
20
ns
t
SU;DAT
Set Up Time — READ
560
ns
t
HD;DAT
Hold Up Time — READ
615
ns
t
SP
Input Filter
50
ns
C
in
Input Capacitance
SDA or SCL
<5
pF
DS90UH927Q
10