3. Select
Connection Settings
to confirm the SPI configuration shown in
matches the controller PCB
. Specifically, SPI mode and CRC/Checksum can vary based on switch
settings. When configuration is complete, press
OK
.
Figure 2-5. DLPC230-Q1 Automotive Control Program Communication Settings
4. Click the
Connect
button. The green circle next to the Connect button then lights up to indicate that
connection was successful to the Cheetah Adapter.
2.5 Steps to Reprogram the Onboard Flash Memory
The DLP5532HBQ1EVM comes with onboard serial Flash that is pre-programmed with software and basic
configuration. The software and configuration can be updated by reprogramming the serial Flash with the
DLPC230-Q1 Automotive Control Program. Steps to re-program the serial Flash are listed below.
1. Using the DLPC230-Q1 Automotive Control Program, that is connected to the EVM, navigate to the
Flash
Program
tab.
2. Navigate to the
Read Flash
sub tab and select
entire flash
content to be saved to a local storage location.
(Note that this step is optional but highly recommended to save the current flash content as a backup.
3. Navigate back to the
Program Flash
sub tab and using the folder icon, select an Image File (.bin) and open
it.
4. Click
Program and Verify Flash Memory
.
Note that if the device is in Display mode, it is automatically be switched to Standby during programming.
Quick Start
14
DLP5532HBQ1EVM Evaluation Module
DLPU108 – MAY 2022
Copyright © 2022 Texas Instruments Incorporated