www.ti.com
Basic Test Setup
3.3.5
High Speed Data Converter Pro (HSDCPro)
1. Start the HSDCPro software tool by selecting Start Menu
→
All Programs
→
Texas Instruments
ADCs
→
High Speed Data Converter Pro.
2. When prompted for the serial number of the board, select the serial number that represents the
TSW1400 that has been connected to the ADS42JBx9. This number is on a sticker on the TSW1400
board.
3. In the Select ADC drop-down box select ADS42JB69. If the GUI asks to download the firmware, select
Yes.
4. Once the firmware has finished downloading, LED's D2-D9 on the TSW1400 should be illuminated
except for USER_LED4.
5. Select Single Tone from the Test Selection drop-down menu.
6. At the bottom-left corner, enter 250M in the ADC Sampling Rate (Fs) box. If using a coherent
frequency input, select Auto Calculation of Coherent Frequencies and use the ADC Input Target
Frequency value for the input frequency
7. If a windowing function is desired, then Blackman should be selected above the plot window. If the
signals are synchronized and coherent, select Rectangular.
8. All boards and software are now setup. Click the Capture button. A sample capture is shown in
Figure 12
for the ADS42JB69 with a 250-MHz clock and 100-MHz input frequency.
Figure 12. High Speed Data Converter Pro (HSDCPro) Sample Capture
19
SLAU468A – November 2012
ADS42JBx9 System Evaluation Kit
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated