CHAPTER 2 

GENERAL CHARACTERISTICS 

2-2 

 

Displays of series DN-109NN, DN-119NN, DN-129NN and DN-189NN 

Displays de las series DT-203X, DT-105X y DT-110X 

 

 

 

Electrical characteristics of the DN-129 displays. 

Supply Voltage........................................... 100 a 240 VAC   50/60Hz. Option 24VDC. 
Consumption ............................................. See section 2.2. 
Display  ....................................................... 7 segments of 250 mm  decimal point. 
 ..................................................................... Red LED color. Reading distance 120 meters. 
Text (Vinyl)  ................................................ White vinyl. 
Parameter memory .................................... Eeprom. 
Environmental Conditions ........................ Operation temperature: -20 to 60ºC. 
 ..................................................................... Storage temperature: -30ºC to 70ºC. 
 ..................................................................... Humidity: 20-90% HR without condensing. 
 ..................................................................... Maximum environmental illumination: 1000 lux. 
 ..................................................................... Sealing: IP41. 

 

 

Summary of Contents for DN-109NN Series

Page 1: ...1787K02I TETRALEC E I S L OPERATION MANUAL FOR PROFINET DISPLAY SERIES DN 109NN DN 119NN DN 129NN DN 189NN...

Page 2: ...imensions and mounting of the displays 2 5 Dimensions and mounting of the DN 109 and DN 119 2 5 Dimensions and mounting of the DN 129 and DN 189 2 6 3 INSTALLATION 3 1 Equipment interfaces 3 1 Power s...

Page 3: ...solutions and installation possibilities The digit sizes are DN 109NN 57 mm DN 119NN 100 mm DN 129NN of 250 mm and DN 189NN 180 mm at reading distances ranging from 30 m to 120 m The application field...

Page 4: ...pply Voltage 100 to 240 VAC 50 60Hz or 24VDC option Consumption See section 2 2 Display 7 segments of 100 mm height decimal point Red LED color Reading distance 50 meters Text LED Formed by LEDs de 5...

Page 5: ...C 50 60Hz Option 24VDC Consumption See section 2 2 Display 7 segments of 250 mm height decimal point Red LED color Reading distance 120 meters Text Vinyl White vinyl Parameter memory Eeprom Environmen...

Page 6: ...9D TL 5 7 38 6 DN 109 9D TV 5 7 34 5 DN 109 10S 4 7 21 2 DN 109 10S TL 5 2 23 2 DN 109 10S TV 5 2 21 2 DN 109 10D 5 7 37 7 DN 109 10D TL 6 2 41 7 DN 109 10D TV 6 2 37 7 DN 119 weight and power consum...

Page 7: ...89 9S 11 2 60 6 DN 189 9S TV 13 2 60 6 DN 189 9D 13 7 117 2 DN 189 9D TV 15 7 117 2 DN 189 10S 12 2 66 9 DN 189 10S TV 14 2 66 9 DN 189 10D 15 2 129 8 DN 189 10D TV 16 7 129 8 DN 129 weight and power...

Page 8: ...2 DN 109 6S T 430 122 DN 109 7S 382 122 DN 109 7S T 478 122 DN 109 8S 430 122 DN 109 8S T 526 122 DN 109 9S 478 122 DN 109 9S T 574 122 DN 109 10S 526 122 DN 109 10S T 622 122 DN 119 3S 324 177 DN 119...

Page 9: ...DN 189 8S 1300 251 67 DN 189 8S TV 1620 251 67 DN 189 9S 1460 251 67 DN 189 9S TV 1780 251 67 DN 189 10S 1620 251 67 DN 189 10S TV 1940 251 67 DN 129 2S 515 366 186 DN 129 2S TV 985 366 186 DN 129 3S...

Page 10: ...ainst the vertical rain drops DN 129f is IP54 which mean that is protected against the rain water The degree of protection of displays DN 109e DN 119e and DN 189e are IP65 it means that are completely...

Page 11: ...tor section must be selected according to the consumption and the ground conductor must have a minimum section of 1 5 mm The power supply connector for 220VAC has 4 contacts and is placed in the lower...

Page 12: ...t screwing cable gland in to the grey case squeezing it strongly with some tool help as an adjustable spanner After we pass the ethernet cable not supplied through the cable gland and start the IP65 c...

Page 13: ...189NN Once placed with the help of a flat screwdriver turn the locking screws until it is tight enough To finish we only have to close the cable glad as strong as possible to avoid that the dust or wa...

Page 14: ...g parameters Before using the display the configuration parameters must be set as required The parameters configuration is done through a menu that is selected by two buttons placed at the bottom part...

Page 15: ...ed till arrive to the maximum value and go on to the minimum value in the next press If the parameter inserted is not compatible with the equipment the parameter will not be accepted For instance our...

Page 16: ...3 Parameter 3 Time without receiving data This parameter specifies a time to warn that the equipment is not receiving data The warning occurs if the programmed time is exceeded If data is received wit...

Page 17: ...arameter C defines the trigger level The most significant digit allows setting up a negative value Parameter B Left Digit Control bit Right Digit Set Reset 0 ON if Value Parameter C 0 No delay No hyst...

Page 18: ...lor configured the RED color is used for parameter configuration 4 2 2 6 Parameter F End of parameters configuration Press the key to exit The parameters will be saved automatically If you wish to kee...

Page 19: ...pressed as ASCII we express the number with its ASCII character For example the character X ASCII can be seen as 58h 88d or 1011000b The number 15 ASCII can be described as 31h 35h 49d 53d or 110001d...

Page 20: ...rk masks etc When done you must generate the new GSD file and update the display with the new configuration Let s see when it is mandatory to change GSD 1 In the Profinet network there is only a DN NN...

Page 21: ...In the case that you need avoid the duplicity of devices with the same Device Name you must use the SW67602 software to change the Profinet parameters create the new GSD and update the Display Firmwa...

Page 22: ...any other fields can result in display malfunction With the communication parameters updated to the installation requirements press OK to accept the new values and choose the PROFINET XML option to c...

Page 23: ...the process the display will be ready to install with the TIA Portal utility or similar If the device is not found the message Error Check the IP Address will be showed This can happen with equipment...

Page 24: ...o list the content Choose the GSD files for the displays which will be included in the Project and press the button Install Wait until the installation process ends and the devices will be ready to be...

Page 25: ...ssign the IP 1 which they will have in the Profinet network The Device view will be displayed double clicking in a particular display 4 Assign the E S address space In the Device view field check that...

Page 26: ...in future updates of the product actually no data is returned 5 Compile and update the project in the PLC With all the elements added and configured compile the project 1 Once verified that there are...

Page 27: ...ition coded according the Table 1 In the WORD datatype format only two data bytes are sent To work with different datatypes follow the next steps 1 Display parameters configuration Use the equipment b...

Page 28: ...ample The next table shows some examples to display numerical data using different data types according to the address range defined in Fig 12 B4 B5 Pos Decimal Dot 01h 00000000 0 02h 0000000 00 04h 0...

Page 29: ...Mode Using the equipment buttons we will configure the parameter 1 with the value 05 The remaining parameters must be configured according to the section 5 2 1 2 Sending of characters sequence of the...

Page 30: ...e value intervals linked to a specified color Red Green and Yellow In this way when the value represented is within the defined interval the value will be showed in the selected color As it was commen...

Page 31: ...ng in Profinet communication the equipment has status LEDs that indicate problems with duplicate IPs repeated Device Names or problems in the ARs between controller and network devices The following t...

Page 32: ...r sole responsibility that the aforementioned product complies with the following European directives Directive 2014 35 UE Low Voltage Directive UNE EN60204 1 2007 A1 2009 Safety of machinery Electric...

Reviews: