CHAPTER 3
INSTALLATION
3-1
DN-109AT, DN-119AT, DN-129AT and DN-189AT display series
3.
INSTALLATION
The installation of the DN-109AT, DN-119AT, DN-129AT and DN-189AT is not particularly
delicate but some important considerations must be taken into account.
The display must not be anchored to places subject to vibrations, nor should it be installed in
places which generally surpass the limits specified in the display characteristics, both in terms of
temperature and humidity.
The degree of protection of displays DN-109AT, DN-119AT, DN-129AT and DN-189AT is
IP41, meaning that they are protected against penetration by solid foreign objects of a diameter of
about 1mm and against the vertical fall of water droplets.
Displays DN-109AT, DN-119AT, DN-129AT and DN-189AT should not be installed in places
with an illumination level in excess of 1000 lux. Neither should the display be placed in direct sunlight
as visibility would be lost.
In the electrical installation, proximity to lines of high intensity circulation and high voltage lines
must be avoided, as well as proximity to High Frequency generators and U/F converters for motors.
3.1.
Power supply.
The power supply must be 88 to 264VAC, 47 to 63 Hz or 19 to 36VDC.
The power supply conductor section will be in line with consumption and the ground conductor
will be a minimum section of 1.5m².
The power supply connector for 220VAC has 3 contacts and is situated in the lower part of the
unit. Connect the power wires following the schema below
The power supply connector for 24VDC has 4 contacts and is situated in the lower part of the
unit. Connect the power wires following the schema below
1
3
2
1- 230V
2- 230V
3- GND
1
3
2
1- 24V
2- 0V
3- GND
4