Parameter 3: Time offset:

 This parameter allows the user to configure its time zone, as well as changing the 

time offset in summertime/wintertime when configuring it manually, or for personal purposes; always counting 
that  internal  time  count  of  the  clock  is  GMT.  First  digit  shows  an  upper  hyphen  when  adding  time  and  a 
hyphen when subtracting  

Parameter  4:  Display  configuration

:  This  parameter  configures  other  functionalities  of  the  display,  as  the 

brightness and the sync options. 
Brightness configuration consists of two parts: 

Left digit. Manual or automatic control of brightness 

0 - Automatic control of brightness depending on the room light. 
1 - Manual control of brightness. Fixed brightness depending on the right digit. 

 

Right digit. Brightness level. 
The functionality of this digit depends on the left digit: 

Automatic 

mode 

–  Selection  of  the  minimum  brightness  of  the  display  when  the  room  is  in 

darkness. Minimum brightness is 1 and maximum is 5. With light, the display adapts to the amount of 
light in the room. 

Manual mode 

- Selection of the brightness level. 1 is minimum and 5 is maximum brightness 

 

The second parameter (Accessed through the Enter  key once selected the brightness configuration) 

configures  the  time  sync  depending  on  the  capabilities  and  the  user  desires.  If  the  user  selects  a  sync  not 
allowed by capabilities, the display will not sync. For example, a display without Ethernet connection, selecting 
SNTP sync will have no effect. Options are: 

0.  Do not sync. 
1.  Sync with another display through Ethernet. 
2.  Sync through SNTP. 
3.  Sync with another display through RS-485. 
4.  Sync through GPS. 

 

Parameter  5:  Display  power-up  time: 

This parameter configures the time the display changes form power-

.save  mode  to  full-operative  mode.  When  accessing  in  this  parameter,  the  hour  the  display  changes  to  full-
operative  mode  is  shown.    When  the  Enter  key  is  pressed,  the  minutes  are  shown.  To  go  back  to  the 
parameter menu, press the Enter key again. 

Parameter  6:  Display power-down  time: 

This parameter configures the time the display changes from  full-

operative  mode  to  power-save  mode.  When  accessing  in  this  parameter,  the  hour  the  display  changes  to 
power-save  mode  is  shown.    When  the  Enter  key  is  pressed,  the  minutes  are  shown.  To  go  back  to  the 
parameter menu, press the Enter key again. 

 

Parameter 7: Website language. This parameter is shown if the display includes Ethernet option. 

0 - Catalan 
1 - Spanish 
2 - English 

– French 

4 - German 
 

Parameter  8:  Display  IP.  This  parameter  is  shown  if  the  display  includes  Ethernet  option. 

This 

parameter  allows  the  user  to  change  the  IP  address  of  the  display.  Access  this  parameter  pressing  the 
Advance  key.  Once  inside,  the  first  number  of  the  IP  address  is  shown.  Modify  it  using  the  Increase  and 

Advance keys and validate it using the Enter key. Do the same with the other 3 numbers of the IP address. To 
identify  each  number,  think  that  the  first  number  is  shown  without  decimal  point.  Next  numbers  appear  with 
decimal points, shifting left each number. 

Summary of Contents for 1660K110F

Page 1: ...sing one of the parameters of the display see GPS option in this manual If the display includes option NE Ethernet connectivity this display hosts a web site where the user can see the status of the d...

Page 2: ...e the methacrylate cover Place the 4 supplied plugs at the distance showed in the drawing Place the 2 upper screws leaving their head outside for 4 mm Hang the display using the upper side zig zag Pla...

Page 3: ...gth 2 meters Timed power up of the display This display operates in two operation modes full operative mode and power saving mode In power saving mode the display does not show the time in order to sa...

Page 4: ...uration easy for the user when changing a parameter a point is turned on This point changes depending on the sub parameter if it exists the user is in 8 8 88 88 88 8 8 88 88 8 8 ENTER ENTER ENTER Para...

Page 5: ...y without Ethernet connection selecting SNTP sync will have no effect Options are 0 Do not sync 1 Sync with another display through Ethernet 2 Sync through SNTP 3 Sync with another display through RS...

Page 6: ...s 8 bits Odd 1 17 9600 Bauds 8 bits Odd 1 18 19200 Bauds 8 bits Odd 1 19 4800 Bauds 7 bits No parity 2 20 9600 Bauds 7 bits No parity 2 21 19200 Bauds 7 bits No parity 2 22 4800 Bauds 8 bits No parity...

Page 7: ...isplays that include GPS sync with the GPS standard signal This allows a better time sync without Ethernet connectivity GPS antenna includes a magnet that can be fixed to a ferric surface This antenna...

Page 8: ...range of you LAN it is recommended to use the PC program Display Discoverer downloadable from the web www lartet com In this program the displays connected to the LAN are displayed as well as their IP...

Page 9: ...1660K110F Page 9 of 29 Tip the new IP and click OK There will appear a message in the main window with the message sent to the display...

Page 10: ...1660K110F Page 10 of 29 After some seconds click the Refresh button The display appears with the new IP Click the display IP to open a new tab in the browser The main page of the web server is shown...

Page 11: ...ually is in a difficult access point The web page can be accessed remotely if the router is correctly redirected See Annex 2 View the web page remotely for more information The main page shows the sam...

Page 12: ...in the field The second tab allows configuring the network parameters of the display including the IP address DNS etc The display can use DHCP to get these parameters on its own The name of the displ...

Page 13: ...ctions parameters seen from the webpage the user must configure Other parameters don t care Networks with one display One display Ethernet network Ethernet network Time and date introduction by user i...

Page 14: ...Both are configured the same way Ethernet network Ethernet network Ethernet network Ethernet network SNTP server Configure net parameters Sync SNTP Write the server addres in the field SNTP server Con...

Page 15: ...hers sync with the server display Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server display Configure...

Page 16: ...NTP server and serves the time to the other displays Ethernet network Ethernet network Client display Configure net parameters Sync Display Ethernet Write the display server addres in the field Server...

Page 17: ...0F Page 17 of 29 Sync through SNTP All displays connect to the SNTP server This works for both cases connecting to a local SNTP server o a cloud SNTP server All displays update from the SNTP server sp...

Page 18: ...nt to is 9760 The following frames can be sent Command Code Data End of block Display time request P H Display temperature request P T Display humidity request P U Time programming F H Display time re...

Page 19: ...II R T T T T Hexa 52h 54h 2Eh Example Temperature 17 2 C Code Data End of block ASCII R T 1 7 2 Hexa 52h 54h 31h 37h 2Eh 32h Display humidity request Frame This frame only includes the code This does...

Page 20: ...ar Space Hour Minute Second End of block ASCII F H DD MM AA HH MM SS Hexa 46h 48h 20h Example 13 06 00 16 05 2013 Code Data End of block Code Day Month Year Space Hour Minute Second End of block ASCII...

Page 21: ...a server and the others will configure with it The parameter 9 1 RS 485 configuration must be the same for all RS 485 network There are many configurations possible only with RS 485 or combining diff...

Page 22: ...1660K110F Page 22 of 29 Sync through a display with GPS...

Page 23: ...1660K110F Page 23 of 29 Sync though a display with Ethernet connected to a SNTP server...

Page 24: ...Display humidity request P U Time programming F H Display time request Frame This frame only includes the code This does not send any data Code Address End of block ACII P H H L Hexa 50h 48h Example...

Page 25: ...4h Example Request temperature from the display in address 03 Code Address End of block ACII P T 03 Hexa 50h 54h 30h 33h Response frame Code Address Data End of block ASCII R T H L T T T Hexa 52h 54h...

Page 26: ...Response from the frame sent in the example before Humidity 60 Code Address Data End of block ASCII R U 03 6 0 Hexa 52h 54h 30h 33h 36h 30h Time programming Frame Code Address Data End of block Code A...

Page 27: ...nal Port The same port as the start port Internal Start Port The port the user enters wants to enter the display In this case the port is 80 which is the standard web page access IP address The LAN IP...

Page 28: ...es with the following European directives Directive LVD 2006 95 CEE Low Voltage Directive Standard UNE EN61010 1 Security in electric equipment Directive EMC 2014 30 UE Electromagnetic Compatibility S...

Reviews: