Operation and Storage Manual of Panel Heater

RESET to default settings

If the customer wants reset the convector to factory settings – by pushing the 

“Mode”  button 

 for 3 sec and select “RESET” mode 

 by pushing any of 

the buttons:   

 or 

.  Confirm with “Mode”  button 

.

 

Visualization on Display in “RESET” settings 

:

After using the reset function, the following functions will be re-set:
- clock time
- temperature correction value 0⁰C
- function Anti-frost mode is activated
- adaptive start is activated
- weekly program – 24/7 is reset.

Open window/door function 

Room temperature control with open window detection - the product is 
equipped with an integrated electronic device that reduces the heat output 
when detects an open window or door. A sensor is used to detect eventual 
drop in the room temperature. If the temperature falls more than 5˚C, the 
convector will switch off by itself. Within 15 min the open window detection 
should turn the appliance off. When the room temperature rises by at least 
0.5°C and the difference from the initial set point is below 5°C, the convector 
switches itself on with the settings already made. If the temperature does 
not rise for more than 60 minutes, the convector enters Standby mode. The 
function is allowed to be cancelled manually.
The function can be switched Off manually. 

 

Deactivation of Open window/door function 

:

If the customer wants to change it - by pushing the “Mode”  button 

 for 

3 sec and select “Open window”  mode 

 by pushing any of the buttons:   

 or 

. Confirm with “Mode” 

  button. User has to push 

 button 

to reach ‘’OFF”.  Confirm with “Mode” 

 button. In this case function “Open 

window”   is switched OFF.

 

Activation of Open window/door function 

:

To return again in condition ‘’ON’’ –  by pushing the “Mode”  button 

 for 

3 sec and select “Open window”  mode  

 by pushing any of the buttons:    

 or 

. Confirm with “Mode” 

  button. User has to push 

 button 

to reach ‘’ON”.  Confirm with “Mode” 

 button. In this case function “Open 

window”   is switched ON.

Note:

 When the “Open window” function is enabled, the “Anti-frost” function 

does not work!

 

Visualization on Display in “Open window” settings 

:

Keyboard lock (Protection from children)

When user turns on this function, all keys of the control panel remain locked. 
Hold buttons  

 and “Mode”  

 together for 3 seconds. The display should 

show a message when this mode is activated. When user wants to turn off this 
function has to hold the same button combination for 3 seconds.

Activation/deactivation: Holding 

 and “Mode”  

 buttons for 3 seconds 

the keyboard gets locked.

To unlock the control panel, hold 

 and “Mode”   

buttons for 3 seconds.

Visualization on Main Display when activating and deactivating the 
function “Protection from children”: 

 Day and time – settings

First step or use after factory reset function

Set the current time and day by pushing the “Mode”  button 

 for 3 sec and 

select “DAY  TIME” mode by pushing any of the buttons:   

 or 

. Confirm 

with “Mode” button 

Set a schedule for the first day of the week

Select “DAY OF THE WEEK”  mode by pushing any of the buttons:  

 or 

Confirm with “Mode” button 

.

Select by pushing any of the buttons:  

 or 

 reach current day of the 

week (Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday) .  
Confirm with “Mode”  button 

Set time

Select “TIME” mode by pushing any of the buttons:  

 or 

 . Confirm 

with “Mode” button 

.

The hour icon is flashing and by pushing any of the buttons: 

 or 

  

reach actual hour time. Confirm with “Mode”  button 

. The minute icon 

is flashing and by pushing any of the buttons:   

 or 

 reach actual 

minute time. Confirm with “Mode”  button 

. (range 00.00-24.00)

Weekly program (timer) 24hours/7days  

 

Min 300 sets of time periods

Electronic thermoregulator with weekly program (timer) 24/7 - electronic room 
temperature control plus weekly timer means the product is equipped with 
an electronic device, either integrated or external, which allows the product 
automatically to vary its heat output over a certain time period. In relation 
with a certain required level of indoor heating comfort. It allows the setting 
of timing and temperature levels for a full week. During the 7-day period the 
settings must allow a variation on a day-to-day basis;

 Deactivation 

If the customer wants to deactivate it, he/she has to push ON/OFF 

 

button(The heater goes into “heating” mode.) or press for 1.5 sec ON/OFF  
button for OFF the heater. 

 Activation

If the customer wants to set “Weekly shedule (timer)” mode- by pushing the  
“Mode”  button 

 for 3 sec and select “Weekly shedule” 

 mode by 

pushing any of the buttons:   

 or 

. Confirm with “Mode”  button 

There have three options:

-  CREATE PROGRAM

-  ERASE PROGRAM

-  VIEW PROGRAM

Create program

Summary of Contents for CN06 060 EA W

Page 1: ...ltd CN 06 EA CLOUD AS W 230V 50Hz 600 1000 1400 2000W 206403 v1 0 ENELECTRIC PANEL HEATER 2 12 Operation and Storage Manual of Panel Heater BG 13 23 ROCONVECTOR ELECTRIC 24 34 Instruc iuni de utiliza...

Page 2: ...eration only When positioning the appliance do not cover the safety grilles do not hamper the incoming and outgoing air flow All objects must be at a safe distance of at least 1 meter away from the ap...

Page 3: ...not less than 1 meter and it is compulsory the appliance to be wall mounted If you do not feel sure about the installation of this panel heater in a bathroom we recommend you to consult a professional...

Page 4: ...e in Comfort mode User could set the time range for operating in Sleep mode then the appliance switches to Comfort mode By default 6 hours Activation of Sleep mode Push the button Mode for 3 sec and s...

Page 5: ...from the measured temperature in a specific location in the room indicates that the room where you use the convector in is not well insulated or the temperature is not the same all around the room Exa...

Page 6: ...panel remain locked Hold buttons and Mode together for 3 seconds The display should show a message when this mode is activated When user wants to turn off this function has to hold the same button co...

Page 7: ...ecessary the convector to be switched on and heated the set temperature is higher than the ambient temperature When the temperature of the heater rises the natural air flow starts in the room Colder a...

Page 8: ...teed and up to 180 minutes not guaranteed If the time is more than 120 min the appliance going to Stand by mode PROTECTION The appliance is equipped with a safety thermo turn off device which automati...

Page 9: ...lectric appliances contain valuable materials and consequently they should not be treated as domestic waste We ask for your cooperation and your active contribution to protect the resources and the en...

Page 10: ...ion yes With distance control option no With adaptive start control yes With working time limitation no With black bulb sensor no Model identifier s 1 CN06 060 EA AS W 2 CN06 100 EA AS W 3 CN06 140 EA...

Page 11: ...ection yes With distance control option yes With adaptive start control yes With working time limitation no With black bulb sensor no Model identifier s 1 CN06 060 EA CLOUD AS W 2 CN06 100 EA CLOUD AS...

Page 12: ...oid obstructions that may prevent normal air exchange between the appliance and the indoor air Open window door detection is not enabled Switch on open window door detection Adaptive start function do...

Page 13: ...BG 13 3 3 8 3 8 8 a 100 1 100 UVA UVA 45 3 2 1 2 3 1 volume 1 4 2 volume 2 3...

Page 14: ...BG 14 5 HD60364 7 701 IEC 60364 7 701 2006 IP24 2 volume 2 1 3 VOLUME 3 25 3 CN06 1 5 ON OFF ON OFF 1 Mode 1 Mode 3...

Page 15: ...BG 15 1 1 1 23 C Mode 3 Mode 10 30 C Mode On Off 1 5 Mode 1 2 18 C Mode 3 Mode Mode Mode Mode 00 00 24 00 On Off 1 5 Mode 1 3 3 C 6 Mode 3 Mode Mode Mode 00 00 24 00 On Off 1 5 Mode 2...

Page 16: ...1 5 On Off 1 5 0 5 6 10 30 C Mode 3 Mode 12 Mode Mode 0 5 4 Mode 3 00 ON OFF 0 96 5 stand by 5 Mode 3 Mode OFF Mode Mode 3 Mode ON Mode 60 4 7 4 C 18oc 22 22 60 4 22 22 0 C Mode 3 Mode 4 C 4 C Mode M...

Page 17: ...e 0 C 50 60 23 C 3 C Ct 7h 2h 0h 24h 4 C 1 C 17 2h 0h 4 4 24 Ct 30 1 C Ct Mode 3 Mode OFF Mode Mode 3 Mode ON Mode Mode 3 Mode 0 C 5 C 15 0 5 C 5 C 60 Mode 3 Mode OFF Mode Mode 3 Mode ON Mode Mode 3 3...

Page 18: ...7 ON OFF 1 5 ON OFF Mode 3 Mode Mode 1 Mode 2 00 00 24 00 Mode 00 00 24 00 Mode 3 10 30 C Mode 22 C 12 30 15 00 ON OFF 0 5 30 Mode Mode Mode Mode ON OFF AirSafe CN 06 xxx E CLOUD AS W CN 06 xxx E AS...

Page 19: ...e ON Mode Air Safe 2 45 tilt Wi Fi CN 06 xxx EA CLOUD AS W CN 06 xxx EA CLOUD W Wi Fi Mode 3 Wi Fi Mode Wi Fi OFF Mode Mode 6 Wi Fi Mode Wi Fi ON Mode Mode 3 Wi Fi Mode Wi Fi LOCAL Mode Wi Fi 100 5 Mo...

Page 20: ...www tesy com CN 06 060 EA CLOUD AS W 600W 10 23 m3 4 9 m2 CN 06 100 EA CLOUD AS W 1000W 24 33 m3 10 13 m2 CN 06 140 EA CLOUD AS W 1400W 34 45 m3 14 18 m2 CN 06 200 EA CLOUD AS W 2000W 46 65 m3 19 26...

Page 21: ...0 1 00 1 40 2 00 kW elmax 0 57 0 92 1 32 1 93 kW elmin 0 00 0 00 0 00 0 00 kW el SB 0 0002 kW 1 CN06 060 EA AS W 2 CN06 100 EA AS W 3 CN06 140 EA AS W 4 CN06 200 EA AS W 230V 50Hz 1 2 3 4 Pnom 0 60 1...

Page 22: ...1 00 1 40 2 00 kW elmax 0 57 0 92 1 32 1 93 kW elmin 0 00 0 00 0 00 0 00 kW el SB 0 00054 kW 1 CN06 060 EA CLOUD AS W 2 CN06 100 EA CLOUD AS W 3 CN06 140 EA CLOUD AS W 4 CN06 200 EA CLOUD AS W 230V 5...

Page 23: ...BG 23 ON OFF Protection from children 4 100W m2 2 50 m 30W m3 Adaptive start Adaptive start Adaptive start Adaptive start t1 t2 t1 t2...

Page 24: ...it pentru utilizare n cre terea animalelor acesta este destinat numai pentru uz casnic Nu acoperi i grilele de siguran nu bloca i intrarea fluxului de aer prin a ezarea aparatului vizavi de orice supr...

Page 25: ...i unitatea trebuie s fie montat pe perete Dac nu sunte i sigur cu privire la modul de instalare a acestui convector n baie v recomand m s consulta i un electrician profesionist Nota n cazul n care con...

Page 26: ...ratura Pe afi aj apare pictograma modului c i temperatura setat 1 3 Modul Somn cu op iunea On Off la dou ore dup activare convectorul scade temperatura setat cu 3 C comparativ cu cea setat n modul Con...

Page 27: ...pozi ia a ezat n caz de constatare a unei diferen e n diapazonul 4 pute i seta ajustarea necesar din meniul convectorului O condi ie important func ia nu se poate seta numai dup temperarea nc perii ca...

Page 28: ...e 3 secunde i selecta i func ia Fereastr U deschise apas nd butoanele sau i confirma i cu butonul Mod Mode Utilizatorul poate ap sa butonul pentru a atinge ON pornit Confirma i cu butonul Mod Mode n a...

Page 29: ...lzitorul are o intensitate i o energie foarte redus i nu are efecte d un toare asupra oamenilor plantelor i animalelor 3 F r generarea de ozon peroxid de hidrogen molecule organice sau anorganice sau...

Page 30: ...ornire nt rziat Programul s pt m nal Ie ire din fiecare meniu ap s nd o dat butonul ON OFF MODUL DE EROARE Dac pe afi aj apare t1 sau t2 sistemul de autodiagnosticare a detectat o problem n termosenzo...

Page 31: ...lzit minim garantat de nc lzire la un coeficient mediu de conductivitate ter mic 0 5 W m2K pentru nc perea nc lzit La valori ridicate pentru volumul suprafa a nc lzit se realizeaz la o valoare medie...

Page 32: ...i camerei cu detectarea unei ferestre deschise da cu op iune de control la distan nu cu demaraj adaptabil da cu limitarea timpului de func ionare nu cu senzor cu bulb negru nu Identificatorul de model...

Page 33: ...ise da cu op iune de control la distan da cu demaraj adaptabil da cu limitarea timpului de func ionare nu cu senzor cu bulb negru nu Identificatorul de model e 1 CN06 060 EA CLOUD AS W 2 CN06 100 EA C...

Page 34: ...u ideschise necesit o temperatur stabil anterioar stabil Evita i blocajele care pot interfera cu schimbul normal de aer ntre unitate i aerul din camer Func ie de identificare de fereastr u deschis nu...

Page 35: ...RS 35 Djeca manje od tri godine treba osim ako pod nadzorom 3 8 3 8 ure aja 100 1 50 100 22 UVA UVA 45 2 1 2 3 1 volume 1 4 2 volume 2 3...

Page 36: ...RS 36 5 HD60364 7 701 IEC 60364 7 701 2006 IP24 2 volume2 1 3 VOLUME 3 25 3 CN06 1 5 ON OFF ON OFF 1 Mode 1 Mode 3 1 Comfort Eco Sleep 1 1 Comfort 23 C...

Page 37: ...5 Mode Comfort Heating 1 2 Eco 18 C Comfort Eco Mode 3 Mode Mode Mode Mode 00 00 24 00 Comfort Eco On Off 1 5 Mode 1 3 Sleep 3 C Comfort Comfort 6 Sleep Mode 3 Sleep Mode Mode Mode 00 00 24 00 Comfor...

Page 38: ...ode Mode 0 5 4 Mode 3 00 Delayed start Delayed start ON OFF 0 96 Delayed start Anti frost 5 stand by 5 Anti frost Mode 3 Anti frost Mode OFF Mode Mode 3 Anti frost Mode ON Mode Anti frost T C Correcti...

Page 39: ...1 C 17 2h 0h 4 4 24 Ct 30 1 C Ct Mode 3 Mode OFF Mode Mode 3 Mode ON Mode Mode 3 Mode 0 C Open window door 5 C 15 0 5 C 5 C 60 Open window door Mode 3 Mode OFF Mode Mode 3 Mode ON Mode Keyboard lock...

Page 40: ...Mode 3 Mode Mode 1 Mode 2 00 00 24 00 Mode 00 00 24 00 Mode 3 10 30 C Mode 22 C 12 30 15 00 ON OFF 0 5 30 Mode Mode Mode Mode ON OFF Air Safe CN 06 xxx E CLOUD AS W CN 06 xxx E AS W Air Safe Air Safe...

Page 41: ...afe 2 45 tilt Wi Fi CN 06 xxx EA CLOUD AS W CN 06 xxx EA CLOUD W Wi Fi Mode 3 Wi Fi Mode OFF Mode Mode 3 Wi Fi Mode ON Mode Mode 3 Wi Fi Mode Wi Fi LOCAL Mode Wi Fi 100 5 Mode 3 Mode 0 Mode Mode 3 Mod...

Page 42: ...om CN 06 060 EA CLOUD AS W 600W 10 23 m3 4 9 m2 CN 06 100 EA CLOUD AS W 1000W 24 33 m3 10 13 m2 CN 06 140 EA CLOUD AS W 1400W 34 45 m3 14 18 m2 CN 06 200 EA CLOUD AS W 2000W 46 65 m3 19 26 m2 0 5 W m2...

Page 43: ...RS 43 ON OFF Protection from children 4 100W m2 2 50 m 30W m3 Adaptive start Adaptive start Adaptive start Adaptive start t1 t2 t1 t2...

Page 44: ...TESY Ltd Head office 1166 Sofia Sofia Park Building 16V 2nd Floor PHONE 359 2 902 6666 FAX 359 2 902 6660 office tesy com 206403_001...

Reviews: