Operation and Storage Manual of Panel Heater
5
English
any of the buttons:
or
and confirm with “Mode” button
, user
can enter the time and temperature, when it will automatically go to “Heating”
mode. Initially a setting of 12 hours is set by default and by pushing
or
buttons user can change the time settings in the desired direction.
After the hour of “delay start” mode is chosen, press “Mode”
button for
confirmation. After that set the temperature at which the convector will start
operating by pushing of any of buttons:
or
. Confirm with “Mode”
button
. If any of
or
buttons is held for more than 0.5 seconds,
the time and temperature settings start automatically increase or decrease at a
rate of 4 units per second. Confirm with “Mode” button
or don’t press any
button for 3 seconds.
If user enters time – 00, this mode will not be implemented. If the “Delay start”
mode is already enabled and user selects the “Delay Start” mode again, it can
be changed the remaining time in both possible directions. You can exit this
mode by pushing the “On/Off”
button. Then panel heater will go into
“Heating” mode. The “Delay start” needs to be set from 0 to 96 hours.
Visualization on Display in “Delay start” settings
:
The display shows “Delay start” in the top and the set temperature
Anti-frost mode
If the room temperature falls below 5°C and the panel heater is off, the heater
will turn on automatically in order to prevent freezing of the area. Indication –
in left top corner - only when work the anti-frost mode
Factory settings of the function is ON (switched On).
Activation and deactivation of Anti-frost mode
- If the customer wants to change it – push “Mode” button
for 3 sec and
select “Anti-frost” mode
by pushing any of the buttons:
or
.
Confirm with “Mode” button
and user can push
button to reach ‘’OFF”.
Confirm with “Mode” button
.
To activate the function – push “Mode” button
for 3 sec and select “Anti-
frost” mode
by pushing any of the buttons:
or
. Confirm with
“Mode” button
. It starts blinking and user has to push
button to
reach ‘’ON’’. Confirm with “Mode” button
.
Visualization on Display in “Anti-frost” settings
:
“Temperature correction for the sensor” function
Due to the specifics of the temperature profile in some premises there may
be difference from the temperature shown on the display and the actually
measured temperature in the various locations of the heating appliance in the
room.
See the temperature shown on the display of the appliance
Measure the temperature at a place where the temperature is “comfortable”
enough for you (usually at a height of 60 cm from the floor, in sitting positon).
If you find a difference within a range of ±4°С, you can set the necessary
correction in the convector’s menu (It is important to note that this function
can be set only after the temperature has become the same all around the
room, and depending on the room type, the minimum required time is 7
hours) by entering the temperature difference resulting between the value on
the display and the actually measured temperature.
This function is used with the purpose of providing better temperature
comfort and energy saving for the user of the electric convector in the room
which it is in. A temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that the room where you
use the convector in is not well insulated or the temperature is not the same all
around the room.
Example
: a convector in a room on a stone floor – the convector displays 18°С
(the set temperature is 22°С), the actually measured temperature (feeling of
reached comfort temperature) is 22°С at a height of 60 cm from the floor - > in
this case the convector continues to overheat the room (this is a direct energy
loss, but the convector cannot reach the set temperature because it measures the
temperature at a low height close to the floor) and it will never switch off. In this
case a temperature correction of +4°С needs to be applied to the sensor, thus the
convector will display 22°С and it will start switching off, and eventually it will
maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
If the customer wants to change it - by pushing “Mode”
button for 3
sec and select “Temperature correction”
mode by pushing any of the
buttons:
or
. Confirm with “Mode” button
– by pushing
or
button user can reach a temperature correction in the diapason from
‘’-4°C” up to ‘’+4°C”. Confirm with “Mode” button
.
If user wants to see the already set correction, should press “Mode” button
for 3 sec and select “Temperature correction”
mode by pushing any
of the buttons:
or
. Confirm with “Mode” button
. User can
change it by pushing button
or
to give a new value of correction in
the diapason ±4°C. Confirm with “Mode”
button.
If the factory reset function is used, the temperature correction has to be set
again. The factory setting of its value is 0°C.
Visualization on Display in “Temperature correction” settings
:
Function Adaptive start
Adaptive start is a function which predicts and initiates the optimal start of
heating in order to reach the set-point temperature at the desired time;
Test according to user instruction / documentation. The function is tested in a room
with a continuous heat demand of 50 - 60% with reference to the wattage of the
test device. The product is working at a comfort temperature 23°C ± 3°C setpoint
until stable conditions. This temperature is the reference comfort temperature “Ct”.
Activate a set-back period of 7h +2h/-0h per 24h with a set-back of 4°C ± 1°C . The
comfort period being 17 -2h/+0h hours. With the adaptive control activated - let
the heater thermostat working during 4 periods (4 x 24 hours) of comfort and low
setback cycles. After the latest low setback period finishes the comfort temperature
“Ct” should be reached within ± 30 minutes deviation to the time target - with a
maximal difference of ± 1⁰C from the reference comfort temperature “Ct”.
- Factory settings of the function is ‘’ON”
Deactivation of function Adaptive start
:
- If the customer wants to change it – by pushing the “Mode” button
for
3 sec and select “Adaptive start”
mode by pushing any of the buttons:
or
. Confirm with “Mode” button
and user can push
button
to reach ‘’OFF”. Confirm with “Mode” button
. In this case, the function
adaptive start is switched OFF.
Activation of function Adaptive start
:
To return again in condition ‘’ON’’ – by pushing the “Mode” button
for
3 sec and select “Adaptive start”
mode by pushing any of the buttons:
or
. Confirm with “Mode” button
and user can push
button
to reach ‘’ON”. Confirm with “Mode” button
. In this case the function
Adaptive start is switched ON.
Visualization on Display in “Adaptive start” settings
: