A. Safety 

instructions

Avoid electrical hazards:

  Never use the measuring instrument and 

fi

 ne pressure probe to measure on or near 

live parts!

Protect the 

fi

 ne pressure probe:

  Never store the measuring instrument/measuring cells together with solvents 

(e.g. acetone). Do not use any desiccants.

Product safety/preserving warranty claims:

 Operate the 

fi

 ne pressure probe only within the parameters speci

fi

 ed in the technical 

data. 

 Handle the 

fi

 ne pressure probe properly and according to its intended purpose only. 

  Never apply force! 
  Temperatures given on probes/sensors relate only to the measuring range of the 

sensors. Do not expose handles and feed lines to any temperatures in excess of 
70 °C unless they are expressly permitted for higher temperatures. 

  Open the measuring instrument only when this is expressly described in the 

instruction manual for maintenance purposes. 

  Carry out only the maintenance and repair work that is described in the Operating 

Instructions. Follow the prescribed steps exactly. For safety reasons, use only original 
spare parts from Testo.

  Any additional work must only be carried out by authorized personnel. Testo will 

otherwise refuse to accept responsibility for the proper functioning of the measuring 
instrument after repair and for the validity of certi

fi

 cations.

Ensure correct disposal:

  Dispose of defective rechargeable batteries and spent batteries at the provided 

collection points. 

  Send the measuring instrument directly to us at the end of its useful life. We will 

ensure that it is disposed of in an environmentally friendly manner.

4

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 0632 3301

Page 1: ...Instruction manual en Fine pressure probe www com information itm com 1 800 561 8187...

Page 2: ...ep this document to hand so that you can refer to it when necessary Identification Icon Significance Comments Important Please pay particular attention Text Text appears on the instrument display Key...

Page 3: ...D Measurements 8 D 1 Measurement with flue gas analyzers 0632 3301 3305 8 D 1 1 E Draught 8 D 1 2 E Delta P 9 D 2 Measurement with flue gas analyzers 0632 3306 3307 10 D 2 1 E Draught 10 D 2 2 E Delta...

Page 4: ...pressly permitted for higher temperatures Open the measuring instrument only when this is expressly described in the instruction manual for maintenance purposes Carry out only the maintenance and repa...

Page 5: ...ue draught for atmospheric gas burners Checking the vacuum in a closed room with simultaneous operation of fireplace and exhaust air equipment Measurement of vacuums in equipment rooms for fireplaces...

Page 6: ...late edges up to a thickness of 4 mm Do not move the brackets sideways towards the outside To open move the brackets forwards and backwards 5 Magnetic holder on rear WARNING Magnetic field May be harm...

Page 7: ...upwards To pry open the connecting joint at the opening carefully and repeatedly move the hanger brackets in opposite direc tions To open move the brackets forwards and backwards Do not move the hang...

Page 8: ...n Measurements OK Finepress probe OK Performing the measurement 1 E Draught OK Measurement begins 2 Stop measuring Stop The reading is recorded Option To print the reading Print 3 Copy the reading to...

Page 9: ...ter value max 1440 min 3 Enter rate Rate Change enter value default value 1 sec The measuring rate must not be greater than the measurement period 4 Start measuring Start The residual time and the cur...

Page 10: ...Options Clipboard Data are saved in the clipboard Options Save The measurement values are saved in a report Options Show Graphic The measurement values are saved in a line diagram 3 Exit function D 2...

Page 11: ...ion D 2 3 E Delta P Program Calling up the function Measurements OK Finepress probe OK E Delta P Program OK Carry out measurement 1 Start measuring Measurement is automatically ended after the end of...

Page 12: ...Pa additionally 1 digit Measuring rate max 1 s Zero point drift none cyclical zeroing Temperature measurement Measuring range Depends on probe max 40 C to 1200 C Resolution 0 1 C Accuracy 0 5 C 40 to...

Page 13: ...0330 Flue draught set 0554 3150 Capillary hose set 0554 1215 Update CD firmware update for testo 330 0554 3351 testo 330 1 LL 0632 3304 testo 330 2 LL 0632 3305 Basic retrofit kit 0563 3344 Professio...

Reviews: