Configuration

 

 

The  top  line  is  the  same  for  all  configuration  screens.  It  contains  a  back  arrow  which,  when 

pressed, switches to the home screen and simultaneously saves the set configuration values, and a line of 5 
symbols  which  represent  the  individual  configuration  screens  –  "alarm  limits",  "time",  "display",  "sound" 
and "factory settings". The selected icon will always lighten up. 
 

Alarm limits configuration screen 
 

 

Fig. 4 – Alarm limits configuration screen 

 
 

Two  alarm  limits  "warning"  and  "alert"  can  be  set  for  the  measured  substances,  the  exceeding  of 

which is always indicated visually on the display (in case of the display being off, the display will light up for 
5 seconds) and acoustically by a single beep of the internal siren. In the event that any alarm persists for a 
long time, the acoustic and visual indication is repeated after 30 minutes. Alarm limits have a hysteresis of 
+/- 10 % of the set value for exceeding the limit. An exceeded “warning” limit is visually indicated by yellow 
and  an  exceeded  “alert”  limit  is  indicated  by  red.  Acoustic  alarms  can  be  switched  off  in  the  "Sound 
Configuration Screen " settings. 
 

 The  alarm  limits  for  CO  cannot  modified  by  the  user  due  to  the  high  hazardousness  of  CO  and  the 

importance of the alarm. For the same reason, it is not possible to turn off the acoustic alarm for CO. If the 
CO limit is exceeded, the internal siren will beep 5 times with a repeat interval of 3 sec and the display will 
light up permanently. 
 

The default limit values, based on international hygiene and medical recommendations, are as follows:  

 

Factory limit settings 

 

 

     

warning

 

    

alert

 

 

Rn

   

300 

   600 

Bq/m

 

Gama

 

    1 

   100 

µSv/hr 

CO

   

 50 

  100 

ppm 

CO

2

   

1000 

2000 

ppm 

VOC

 

                                    50                        70                % 

 
 

When setting the limits, the lower line of symbols allows selection of the substance whose limits 

are to be set. The factory values of the alarm limits correspond to the above table. By pressing the + and - 
buttons or by pressing the alarm value (a numerical pad will pop up) it is possible to change the values. The 
factory values of the alarm limits can be restored to factory settings at any time. 
 

 

Summary of Contents for 042 127 252 000

Page 1: ...The manual is also available at www tesla cz EN RaDEC household air quality indicator Technical description and operation manual v 4 2022 ...

Page 2: ...e The user should become familiar with the basics of the product If there are any problems with operating the product specified on the title sheet please contact TESLA Rubeška 215 1 190 00 Prague 9 Vysočany Czech Republic www tesla cz 1 Introduction This document describes the technical parameters and operation of the RaDEC household air quality indicator It is a product developed and manufactured...

Page 3: ...the top of the case In addition to the real time value shown on the display the product also creates periodic records of all measured quantities These records can be displayed in the form of a graph for each measured variable on the display max 100 records RaDEC can be powered from the mains or from a built in battery Thanks to the built in battery the indicator is portable and can perform measure...

Page 4: ...r more information about radon and how to protect yourself from it visit https www radonovyprogram cz Ideally we would recommend having the RVA at home of 200 Bq m3 at times when persons stay inside but in some older buildings this may be challenging without structural modifications Equivalent dose power from photon radiation X ray and gamma radiation X ray and gamma radiation is high energy elect...

Page 5: ...mum acceptable level for long term residence is typically 1000 ppm Higher levels lead to fatigue headaches and other health problems The appropriate alert limit should be set between 1000 1500 ppm Relative concentration of volatile organic compounds VOC This is the sum of various organic compounds that can be present in the home and can cause respiratory irritation respiratory problems or allergie...

Page 6: ...amma measurement and display interval 3 sec value smoothed By weighted averages CO measuring range 0 800 ppm CO measurement and display interval 3 sec CO measurement accuracy better than 20 5 years O2 measuring range 0 40000 ppm CO2 measurement and display interval 1 min CO2 measurement accuracy 20 VOC measuring range 1 100 VOC measurement and display interval 3 sec Temp measuring range 40 125 C R...

Page 7: ... your finger When the touch screen is switched on the current values of the measured value will be displayed If the built in battery is discharged the product in the portable mode is switched off and can only be switched on and recharged by connecting it via the mains adapter and USB cable to a 230V socket The product can be switched off completely e g for long term storage by touching and holding...

Page 8: ...is indicated by red No alarm limits are indicated for the temperature and humidity symbols Note Pressing means touching a specific place on the display with a finger fingernail or any pointed object under certain pressure If a flashing yellow warning triangle Fig 2 appears in the main field this is an indication of a product error and a list of yellow error states will appear when this triangle is...

Page 9: ...y indicates the total number of records and the record on which the white cursor x is located In the middle below the chart the record value of the measured substance is indicated where the white cursor is located Individual records of the chart can be navigated using the arrows and The buttons and can be used to navigate forward and backward by 100 chart records pages If there are fewer records p...

Page 10: ...ceeded warning limit is visually indicated by yellow and an exceeded alert limit is indicated by red Acoustic alarms can be switched off in the Sound Configuration Screen settings The alarm limits for CO cannot modified by the user due to the high hazardousness of CO and the importance of the alarm For the same reason it is not possible to turn off the acoustic alarm for CO If the CO limit is exce...

Page 11: ...ct the intensity in 5 increments the default value is around 70 You can also set display light time Auto off the display will only light up for 90 seconds after pressing the top button TESLA logo on the product Permanent the display is always lit when the product is connected to a constant power source constant power mode see chapter Operation manual Mode of operation In the portable mode see chap...

Page 12: ...CO2 and VOC measurements After selecting Default limits setup a screen will appear where pressing the Yes button will restore the factory alarm limits This option can be used if it is necessary to restore the limit values set on the Alarm limits configuration screen After selecting CO2 VOC meas calibration a screen will appear where this calibration can be initiated The actual automatic calibratio...

Page 13: ...apacity Battery is charging The battery voltage can also be read on the information screen i The voltage varies between 3 4 V product will be powered off and about 4 15 V full charge Recalibration of CO2 and VOC sensor In case of long term use of the product the CO2 and VOC sensors may show some deviations and therefore it is advisable to perform a user calibration of the sensor User calibration c...

Page 14: ...ct the service department The warranty covers defects in material or workmanship but not damage caused by transport and handling or improper operation Improper and unprofessional operation of the product including breaking the seal will void the warranty The warranty period is extended by the repair period The product must be disposed of as electronic waste at the end of its useful life 10 Documen...

Reviews: