Basic maintenance

 

 
Charging the battery:

 

When operating the  product  in portable mode, the built-in battery must  be checked and recharged if 

necessary. If the battery is discharged, the product will switch off automatically. The product is switched on 
again by connecting the power supply to the USB port. 

The current battery charge status is indicated by the battery icon in the top right corner of the display. 

The  current  battery  capacity  is  indicated  by  the  white  portion  in  the  battery  icon.  Low  battery  is  also 
indicated by an acoustic alarm and a yellow triangle symbol with an exclamation mark on the display (see 
picture below). 

 

Fig. 9 – Incorrect product parameters – low battery 

 
The battery is charged via the USB port using the supplied USB cable. The USB cable can be connected to 

a  PC  or  to  the  supplied  power  adapter.  Plug  the  USB  cable  with  power  supply  into  the  USB  port  of  the 
product. The icon will indicate the battery charging status – the battery icon with flash. The battery is fully 
charged  when  the  battery  icon  is  completely  filled  with  white  colour.  The  battery  is  always  fully  charged 
within a maximum of 8 hours after connecting the power adapter.

 

 

Current battery capacity

 

Full battery capacity

 

Battery is charging

 

 

The  battery  voltage  can  also  be  read  on  the  information  screen  (i).  The  voltage  varies  between  3.4  V 

(product will be powered off) and about 4.15 V (full charge). 

 
Recalibration of CO2 and VOC sensor 

      In  case  of  long-term  use  of  the  product,  the  CO2  and  VOC  sensors  may  show  some  deviations  and 
therefore it is advisable to perform a user calibration of the sensor. User calibration can be started on the 
"Factory  limit  settings  and  CO2  and  VOC  user  calibration  screen".  User  calibration  is  based  on  the 
assumption  that  the  product  is  exposed  to  the  cleanest  possible  air  during  automatic  calibration,  which 
corresponds to the outdoor environment. Therefore, it is necessary to place the product outdoors at least 
30 min before starting the user calibration and during the calibration. Incorrect calibration, such as inside a 
room, will cause subsequent incorrect measurements of CO2 and VOC concentrations. 
 

Faulty product states and product restart 

In case of unexpected behaviour of the product (no reaction, etc.), it is possible to restore the product to 
the factory settings using the restart button  (located on the bottom side of the product behind the small 
hole. You will need a needle or other pointed/narrow object to press it). 

 

7

 

Declaration of conformity

 

   Declaration of conformity will be supplied by TESLA on request. To receive the declaration, please use the 
contact details a

www.tesla.cz

. 

 

 

 

Summary of Contents for 042 127 252 000

Page 1: ...The manual is also available at www tesla cz EN RaDEC household air quality indicator Technical description and operation manual v 4 2022 ...

Page 2: ...e The user should become familiar with the basics of the product If there are any problems with operating the product specified on the title sheet please contact TESLA Rubeška 215 1 190 00 Prague 9 Vysočany Czech Republic www tesla cz 1 Introduction This document describes the technical parameters and operation of the RaDEC household air quality indicator It is a product developed and manufactured...

Page 3: ...the top of the case In addition to the real time value shown on the display the product also creates periodic records of all measured quantities These records can be displayed in the form of a graph for each measured variable on the display max 100 records RaDEC can be powered from the mains or from a built in battery Thanks to the built in battery the indicator is portable and can perform measure...

Page 4: ...r more information about radon and how to protect yourself from it visit https www radonovyprogram cz Ideally we would recommend having the RVA at home of 200 Bq m3 at times when persons stay inside but in some older buildings this may be challenging without structural modifications Equivalent dose power from photon radiation X ray and gamma radiation X ray and gamma radiation is high energy elect...

Page 5: ...mum acceptable level for long term residence is typically 1000 ppm Higher levels lead to fatigue headaches and other health problems The appropriate alert limit should be set between 1000 1500 ppm Relative concentration of volatile organic compounds VOC This is the sum of various organic compounds that can be present in the home and can cause respiratory irritation respiratory problems or allergie...

Page 6: ...amma measurement and display interval 3 sec value smoothed By weighted averages CO measuring range 0 800 ppm CO measurement and display interval 3 sec CO measurement accuracy better than 20 5 years O2 measuring range 0 40000 ppm CO2 measurement and display interval 1 min CO2 measurement accuracy 20 VOC measuring range 1 100 VOC measurement and display interval 3 sec Temp measuring range 40 125 C R...

Page 7: ... your finger When the touch screen is switched on the current values of the measured value will be displayed If the built in battery is discharged the product in the portable mode is switched off and can only be switched on and recharged by connecting it via the mains adapter and USB cable to a 230V socket The product can be switched off completely e g for long term storage by touching and holding...

Page 8: ...is indicated by red No alarm limits are indicated for the temperature and humidity symbols Note Pressing means touching a specific place on the display with a finger fingernail or any pointed object under certain pressure If a flashing yellow warning triangle Fig 2 appears in the main field this is an indication of a product error and a list of yellow error states will appear when this triangle is...

Page 9: ...y indicates the total number of records and the record on which the white cursor x is located In the middle below the chart the record value of the measured substance is indicated where the white cursor is located Individual records of the chart can be navigated using the arrows and The buttons and can be used to navigate forward and backward by 100 chart records pages If there are fewer records p...

Page 10: ...ceeded warning limit is visually indicated by yellow and an exceeded alert limit is indicated by red Acoustic alarms can be switched off in the Sound Configuration Screen settings The alarm limits for CO cannot modified by the user due to the high hazardousness of CO and the importance of the alarm For the same reason it is not possible to turn off the acoustic alarm for CO If the CO limit is exce...

Page 11: ...ct the intensity in 5 increments the default value is around 70 You can also set display light time Auto off the display will only light up for 90 seconds after pressing the top button TESLA logo on the product Permanent the display is always lit when the product is connected to a constant power source constant power mode see chapter Operation manual Mode of operation In the portable mode see chap...

Page 12: ...CO2 and VOC measurements After selecting Default limits setup a screen will appear where pressing the Yes button will restore the factory alarm limits This option can be used if it is necessary to restore the limit values set on the Alarm limits configuration screen After selecting CO2 VOC meas calibration a screen will appear where this calibration can be initiated The actual automatic calibratio...

Page 13: ...apacity Battery is charging The battery voltage can also be read on the information screen i The voltage varies between 3 4 V product will be powered off and about 4 15 V full charge Recalibration of CO2 and VOC sensor In case of long term use of the product the CO2 and VOC sensors may show some deviations and therefore it is advisable to perform a user calibration of the sensor User calibration c...

Page 14: ...ct the service department The warranty covers defects in material or workmanship but not damage caused by transport and handling or improper operation Improper and unprofessional operation of the product including breaking the seal will void the warranty The warranty period is extended by the repair period The product must be disposed of as electronic waste at the end of its useful life 10 Documen...

Reviews: