background image

2

General Precautions

 

never store the unit in hot, or very cold, or humid or dusty places.

 

For an extended storage period, we recommend storing the unit in a cool and dry place.

 

if the scanner is left in extreme cold or hot conditions, allow it to adjust to normal room temperatures before use.

 

only use accessories included with the scanner.

 

When left unused for a long period of time, remove the power plug from the outlet.

 

Always handle the unit with care. Avoid dropping and strong impact.

 

Avoid objects (e.g. neckties, long hair, etc) being caught in the scanner during operation. 

 

do not scan sharp objects or hard abrasive surfaces to avoid damage to the lens and other parts.

 

do not scan documents with glue, grease, correction fluid, or wet ink on it which can cause malfunctions. 

 

operate the unit on a level, well-grounded work surface, and free of excessive vibration.

 

don’t open the unit. risk of electric shock.

 

When moving the scanner, disconnect the power cord and connection cable.

 

When doing maintenance on the scanner, remove the power plug from the outlet.

 

do not leave the scanner within the reach of children.

Environmental Information

discarded electrical and electronic appliances are recyclable and should separate from the household waste. Please actively support in 

conserving resources and protecting the environment by returning this appliance to the collection centers (if available).

safety and precautions

Summary of Contents for iDocScan P100

Page 1: ...l rights are acknowledged Images and screenshots shown inside this Guide are example only which may vary according to the devices used and its operating system P Series is mentioned In this Guide refe...

Page 2: ...rd abrasive surfaces to avoid damage to the lens and other parts Do not scan documents with glue grease correction fluid or wet ink on it which can cause malfunctions Operate the unit on a level well...

Page 3: ...ay 13 scanning Procedure 14 Initiating a Scan 14 Scanning from the Scanner 14 Scanning from iDocScan Touch 15 Scanning via TWAIN Interface 16 Scanning via WIA Interface 17 Stopping a Scan 18 Overview...

Page 4: ...le See p 10 Installation DVD See p 9 Calibration Sheet See p 28 Quick Start Guide The following applications are included in theInstallation DVD h h Scanner Driver TWAIN and WIA iDocScan Touch applica...

Page 5: ...the top locking tabs and the lower tabs on the Input Tray with slots on the Scanner 1 2 3 Push the top locking tabs all the way into the slots on the Scanner then swing the Input Tray down to snap th...

Page 6: ...s larger than A4 6 Input Tray Holds sheets to be fed into the ADF for scanning 7 Paper Guides Adjust the Guides to match the paper width 8 Operation Panel a Power and Status LED 1 Turn on or off the p...

Page 7: ...Solid red indicates the ADF cover is open Status LED 2 Off indicates no scanning activity Solid blue indicates the scanner is in operation Solid red indicates the USB cable is not connected to a comp...

Page 8: ...display with resolution of 800 x 600 or higher 1GB RAM 4GB RAM highly recommended USB 2 0 Hi Speed port DVD ROM drive 5GB available hard disk space for software installation Supported operating system...

Page 9: ...anner please install this application For the detailed information see the Help file integrated in this application h h ABBYY Business Card Reader This application helps to capture store organize and...

Page 10: ...n the system tray h h iDocScan Touch icon might be hidden and require that you click the arrow in the system tray to reveal it NOTE To turn off the power press Power for 4 seconds until the Power LED...

Page 11: ...s into the Input Tray Do not scan fragile photos very thin and thick paper and important originals as misfeeding may wrinkle or damage them If a stack of documents cannot be fed into the Input Tray pr...

Page 12: ...de the Paper Guide to the center 2 Place a stack of business cards face down with the long side parallel with the Paper Guides Adjust the Paper Guides to touch the edges of the cards h h If you are sc...

Page 13: ...first and carefully secure the paper with your hands h h Long paper should be fed one at a time h h Hold the long paper with your hands while scanning to prevent the document being fed as slanted whic...

Page 14: ...er 1 through 9 from the Job Display h h To configure the scan job see p19 3 Press Scan Stop to initiate scanning h h A scan progress dialog box appears and displays the scanned image in the preview ar...

Page 15: ...ge Scan action 5 After scanning is finished the scanned image can be selected and previewed in the Preview and Save dialog box and then saved in a new location Select a file to preview Preview area Se...

Page 16: ...tion 1 Place paper in the Input Tray 2 Open Windows Start menu then launch Presto PageManager from All Program list 3 Click File then Select Source Choose iDocScan P series from the Select Source list...

Page 17: ...r in the Input Tray 2 Click the Start menu select All Programs Accessories then Paint to open Paint Paint 3 From the File menu icon select From Scanner or Camera scanning procedure File menu From Scan...

Page 18: ...stops h h Click Stop Scanning to stop the current scanning and a dialog box will appear asking if you want to save the scanned image h h Click Continue Scanning to continue scanning from the paused do...

Page 19: ...ts to your printer PDF Click it when you want to scan documents into a PDF format MS Paint Click it when you want to scan documents to an application which is TWAIN or WIA compliant OCR Click it when...

Page 20: ...ection for detailed settings 4 Click Apply to set that job number for that configuration 5 Click OK to exit the Job Settings dialog box NOTE If you want to continue configure other scan jobs select th...

Page 21: ...text recognition for the Scan To OCR function File Compression Use the slider to compress a file to reduce the total size High Medium Low The higher the compression level the lower the file size Prin...

Page 22: ...1 A4 210x297mm A5 148x210mm A6 105x148mm B5 182x257mm B5 128x182mm Letter 216x279mm Legal 216x356mm Long Sheet max 3000mm 2 1 Choose Auto to let the scanner automatically detect the size of your orig...

Page 23: ...ank Page Removal Check this box to automatically remove the blank pages from the scanned documents For example when scanning a stack of documents containing both double sided and single sided document...

Page 24: ...docscan touch Improvements and Settings Descreen Descreening helps to reduce moire patterns when scanning magazines or other printed materials After descreening your image may appear blurry NOTE This...

Page 25: ...with the red marks and the black text selecting Red can remove the red marks and scan the black text only To scan all color choose None Original image Color Dropout applied Check the Advanced checkbo...

Page 26: ...number of Total Page Count are accumulated CAUTIONS Be sure to remove the power plug and USB cable before cleaning Be careful not to get the scanner wet Water and liquids entering the inside of the sc...

Page 27: ...Wipe both Scanning Glasses from side to side h h Plastic Rollers and Pinch Roller Wipe these rollers from side to side Rotate the rollers to clean around the surfaces h h Feed Rollers and Separation...

Page 28: ...s over time maintenance 1 Turn on the power of the scanner 2 Remove the plastic foil on both sides of the Calibration Sheet 3 Insert the Calibration Sheet into the Input Tray with the arrow mark facin...

Page 29: ...s online at www mustek com tw Checking Consumable Items Status Check the consumable items counter by clicking i information at the bottom right of iDocScan Touch main menu to display the information o...

Page 30: ...o place 4 Click i information from iDocScan Touch main menu then click Reset next to the counter of Separation Pad Count to set the counter back to 0 maintenance Replacing Separation Roller Replace th...

Page 31: ...Insert and guide the left end of new Separation Roller in its hole then push the right end down into the U shaped holder maintenance 6 Lift the Separation Roller Cover up and snap it into place and th...

Page 32: ...fter cleaning 1 Pull the Cover Tab to open the ADF cover 2 Slide the Paper Guides all the way to the side Open the feed path cover from the notch with your finger maintenance 3 Rotate the lock tab dow...

Page 33: ...back into place and then close the ADF cover 7 Click i information from iDocScan Touch main menu then click Reset next to the counter of Feed Rollers Count to set the counter back to 0 Clearing Paper...

Page 34: ...box opens asking if you want to continue scanning Place the unscanned pages back in the Input Tray then click Yes to continue scanning Click No to stop scanning and save the pages already scanned To...

Page 35: ...he Cleaning the Scanner section to clean the scanner parts Verify the scan quality in the software setting and increase the resolution White or blank page s found Make sure you have placed the documen...

Page 36: ...text based digital images Images with mixed content text images and graphics all in the one page may result less accurate Set the scanner color settings to B W if the text is black against a white bac...

Page 37: ...ed when certain paper or a sticky note attached to document is scanned In such cases the Ultrasonic Multi Feed Detection must be disabled to allow scanning of this type of document Multi page TIFF can...

Page 38: ...t Mode up to 118 3 000 mm at 300 dpi Weight Thickness 28 312 g m2 7 87 lbs 0 04 0 38 mm 0 0015 0 0149 Capacity Max 120 sheets A4 Letter 70 g m2 or 18 lbs with thickness under 0 38 mm 0 0149 Business C...

Page 39: ...idth 9 5 242 mm Interface Hi Speed USB 2 0 File Format Output JPEG jpg BMP bmp TIFF tif Multi TIFF tif PDF pdf PDF A pdf Compatibility TWAIN and WIA Compliant for WindowsWindows XP SP3 Vista 7 8 8 1 D...

Page 40: ...P100 P70 P45...

Reviews: