Teryair 6VMD Series Operation And Maintenance Manual Download Page 4

FF-MM-370-REV - 01

Page 4

Operation and Maintenance Guide  6 VM Air Motor Series

Following symbols are used through out this 

manual.

Safety Instructions

      

   Warning: If not followed could      

   cause personal injuries

Caution: If not followed could result in damage 

to equipment.

    Warning  

This manual must be read and the operating  

instructions carefully followed.

   Warning

Safety and protective clothing, eyewear, head-

gear, ear protection, gloves and footwear to be 

worn during operation of  this Vane motor.

Caution

Install proper guard around the output shaft as  

needed.

Warning.

Operators under 18 not allowed to operate this 

Vane motor operators must be made familiar 

with the instructions in this manual before  

attempting to operate the Vane motor Ensure 

that job site is clear of bystanders. Do Not  

dis-assemble in explosive atmosphere.

    Caution

Use only genuine Teryair or Teryair approved 

accessories.

Warning

This Vane motor is designed for use in an ex         

 p losive environment for Zone 1 & 2 for Gas   

 and Dust.

    Warning

Operate the motor for approximately 2 hours at 

the maximum desired load. Measure the sur-

face temperature of the motor on the casting 

opposite the pipe ports. The maximum surface 

temperature listed on the   motor is for nor-

mal environmental and installation conditions. 

Fort air motors Temp. Class T6 (Gas) and T85° 

C (Dust). The maximum surface temperature 

Ex code

ll 2 G Ex h IIC T6 Gb
ll 2 D Ex h IIIC T85° C Db
Amb. Temp ( +1° C to +40° C)

Checklist for installation in    

hazardous areas

Read air motor label to check that motor has 

been designed for use in a hazardous 

 

application:
•  Hazardous zone
•  Hazardous category
•  Equipment group
•  Temperature class
•  Maximum surface temperatures

   Intended And Prohibitive Use 

     

   Intended Use

Marine and Offshore industries. Can be in 

various application subjected to availability of 

air pressure.
The design of this pneumatic vane motor is 

confirming to EN/ ISO 80079-36 and 80079-37 

explosive atmosphere suitable to use in zone 1 

& 2 area, gas group IIC and Dust group IIIC, 

temp. Class T6 (85°C).

i. EN / ISO 80079-36 : 2016 : Explosive       

atmospheres—Part 36 :Non-electrical  

equipment for explosive atmospheres— 

Basic metod and requirements

ii. EN / ISO 80079-37 : 2016 : Explosive  

atmospheres—Part 37 : Non-electrical  

equipment for explosive atmospheres—

Non-electrical type of protection construction-

al safety ‘c’, control of ignition sources ‘b’, liquid  

immersion ‘k’.
Prohibitive use
Use with non-genuine spare parts or  

accessories is prohibited

Summary of Contents for 6VMD Series

Page 1: ...VMNXXX NEMA Model with Lube Lube Free SG Iron SS NPT BSPT Variants 6VMDXXX IEC Model with Lube Lube Free SG Iron SS NPT BSPT Variants 6 V M Read this manual carefully before installing operating or se...

Page 2: ...tructions 6 Operating instructions 7 Suggested Lubricants 7 Troubleshooting 8 Dis assembly and Re assembly 9 Exploded View for 6VM Air Motor 10 Bill of Materials for 6VM Series SG Iron 11 Bill of Mate...

Page 3: ...12 Nm 105 lbs in Air Consumption 0 to 240 m3 hr 0 to 140 cfm Motor Weight 7 5 kgs 16 5 lbs Operating Pressure 1 4 to 7kg cm2 20 to 100PSI Max Allowable speed 3500 rpm ATEX limit 500 2500 2000 1000 15...

Page 4: ...or on the casting opposite the pipe ports The maximum surface temperature listed on the motor is for nor mal environmental and installation conditions Fort air motors Temp Class T6 Gas and T85 C Dust...

Page 5: ...inches 1 2 meter from the air motor Install the lubricator level with or above the air motor so that the oil mist will blow direct ly into or fall down into the motor Install a ilter in the air line b...

Page 6: ...e Check the direction of the motor airflow A single rotation motor will operate properly only in one direction Single rotation motors require a muffler to be connected to the air port Remove the plast...

Page 7: ...or serviced Air source inadequate Inspect and repair Air source too far from motor Reconfigure setup Suggested Lubricants Brand Above 27 Deg C From 5 Deg C to 27 Deg C Below 5 Deg C Shell Toona R 72 T...

Page 8: ...e To remove the Front Bearing Cap 6 from Front Flange 2 unscrew CSK Bolt 21 from it The O ring 9 and Oil Seal 10 can be now removed from Front Bearing Cap 6 Replace with new ones if found damaged f N...

Page 9: ...REV 01 Page 9 Operation and Maintenance Guide 6 VM Air Motor Series Exploded View for 6VM Air Motor 1 13 17 4 3 7 9 5 19 11 14 18 24 23 16 20 15 12 2 6 9 10 21 FOOT FACE 25 7 18 14 22 10 8 2 IEC NEMA...

Page 10: ...1 1 1 1 1 1 1 6 FRONT BEARING CAP 805 21 11 1 1 1 1 7 BALL BEARING 2Z ZZ 805 50 02 2 2 2 2 1 1 1 1 8 BALL BEARING 2Z ZZ 805 50 01 1 1 1 1 9 O RING 805 40 01 2 2 2 2 1 1 1 1 10 OIL SEAL 805 60 01 1 1...

Page 11: ...03 1 1 5 REAR BEARING CAP 805 27 04 1 1 1 1 1 1 1 1 6 FRONT BEARING CAP 805 27 05 1 1 1 1 7 BALL BEARING 2Z ZZ 805 50 02 2 2 2 2 1 1 1 1 8 BALL BEARING 2Z ZZ 805 50 01 1 1 1 1 9 O RING 805 40 01V 2 2...

Page 12: ...FF MM 370 REV 01 Page 12 Operation and Maintenance Guide 6 VM Air Motor Series Foot Mounting 6VM FACE Mounting 6VM Dimensional Data...

Page 13: ...FF MM 370 REV 01 Page 13 Operation and Maintenance Guide 6 VM Air Motor Series NEMA Flange Mounting 6VM IEC Flange Mounting 6VM...

Page 14: ...CRIPTION S NO We Hereby Certify That The Above Referenced Product Has Tested And Inspected In Accordance With Our Standard Test Pro cedures And Meets The Specifications For Material And Performance Va...

Page 15: ...EN ISO 80079 36 2016 Explosive atmospheres Part 36 Non electrical equipment for explosive atmospheres Basic method and requirements EN ISO 80079 37 2016 Explosive atmospheres Part 37 Non electrical e...

Page 16: ...after deposit with the transporter for shipment iii a Product is not properly preserved packaged stored processed or handled after receipt iv a Product is not used and maintained in accordance with T...

Page 17: ...FF MM 370 REV 01 Page 17 Operation and Maintenance Guide 6 VM Air Motor Series This page is intentionally Left blank...

Reviews: