Specifications
Hands On Bolus flow rate setting range
100.00 mL/h (when using syringe of 5 mL)
100.00 to 300.00 mL/h (when using syringe of 10 mL, 20 mL, 30 mL)
100.00 to 1200.00 mL/h (when using syringe of 50/60 mL)
(100.00 mL/h step)
Hands Free Bolus dose rate setting range
0.01
to 10.00
(0.01
step)
10.00 to 100.00 (0.10 step)
100.00 to 999.00 (1.00 step)
(In units such as mL and mg/kg etc.)
Hands Free Bolus dose time setting range
1 s to 60 min 00 s (1 s step)
Volume delivered display range
0.00 to
10.00 mL (0.01 mL step)
10.00 to 100.00 mL (0.10 mL step)
100.00 to 9999.00 mL (1.00 mL step)
When the dose rate is set in mass units, the volume is expressed in mass units.
(Volume delivered display range: 0.01 ng to 9999.99 kg)
(It will be 0.00 mL when the power is turned on.)
Flow rate
accuracy
Machine accuracy
Within ±1% (flow rate
≥
1.00 mL/h)
Accuracy including
syringe
Within ±2%
(The hourly precision after one hour has passed since the start of solution
delivery, in the case where water or a physiological saline solution is used with
a TERUMO 50/60 mL syringe made in the Philippines (TERUMO_P) at a flow
rate of 1.00 mL/h or more (ambient temperature: 23±2°C) according to IEC
60601-2-24:2012 (EN 60601-2-24:2015) standard.)
Within ±3%
(The hourly precision after one hour has passed since the start of infusion at a
constant flow rate of 1.00 mL/h or more according to IEC 60601-2-24:2012 (EN
60601-2-24:2015) standard.) (For the accuracy of the 50 mL VACCINE syringe,
refer to page 18)
Occlusion detection pressure
10 to 120kPa (set value)
The occlusion detection pressure can be set in 10 levels.
Purge flow rate
Approx. 150 mL/h (when using syringe of 5 mL)
Approx. 300 mL/h (when using syringe of 10 mL)
Approx. 400 mL/h (when using syringe of 20 mL)
Approx. 500 mL/h (when using syringe of 30 mL)
Approx. 1200 mL/h (when using syringe of 50/60 mL)
Alarms
Occlusion alarm, Pressure alarm*
1
, Nearly Empty alarm, Slider Displacement
alarm, Syringe Barrel Detection alarm, Syringe Displacement alarm, Plunger
Displacement alarm, Battery alarm, Re-alarm, Shutdown Notice alarm, Power
Failure alarm, Start Reminder, No Flow Rate alarm, No VTBI alarm*
2
, Flow
Rate/VTBI Volume Judgment alarm*
2
, Completion alarm*
2
, Link Interruption
alarm*
1
.
*
1
: TE-SS830 only
*
2
: Only if the VTBI setting function is enabled (Default: disabled).
Safety functions
Remaining volume
detection setting
function
Sets the Nearly Empty alarm position based on the time before the syringe is
empty.
Occlusion detection
pressure select function
Selects the occlusion detection pressure setting values in 10 levels.
Bolus reduction
function
When an occlusion occurs, the slider is drawn back to reduce internal pressure.
Flow rate range setting
function A
(Soft limits)
The flow rate setting range can be controlled within the “flow rate setting range”
prescribed for each type of syringe.
• When you try to set a value outside the range controlled by this function, a
message asking for confirmation is displayed.
If you confirm the setting, you can set the value which is outside the
controlled range and the display colour of the value changes.