FAULT FINDING

The table below should help solve any problems, which may be 
stopping your lift from operating correctly. If, however, your lift 
still does not operate correctly after referring to this table please 
do not hesitate to call the number on the back of this booklet for 
further advice.

Lift 

Position

Problem

Cause

Remedy

Lower level

Lift will not 

operate

Charger isolation 

switch disabling 

lift

Remote control 

enabler(if fitted) 

not activated.

Ensure charger 

isolation switch 

is on.

Activate remote 

control enabler

with key fob.

Lift rises short 

distance then 

stops

Obstruction on 

ramp

Remove 

obstruction on 

ramp

Upper level

Lift will not 

operate

Charger isolation 

switch disabling 

lift.

Remote control 

enabler(if fitted) 

not activated

Ensure charger 

isolation switch 

is on.

Activate remote 

control enabler 

with key fob

Upper level 

gate not closed 

properly (where 

fitted)

Ensure gate is 

fully closed

Platform safe 

edge obstructed

Remove 

obstruction 

below the lift

Lift operates but 
stops before the 

lower level

Platform safe 

edge obstructed

Remove 

obstruction 

below the lift

11

Summary of Contents for 1100W TSL1

Page 1: ...1100W TSL1 Platform Lift Original instructions...

Page 2: ......

Page 3: ...ion 4 General Do s and Don ts 6 Controls 7 Operating the Lift 8 Emergency procedures 9 Maintenance Servicing 10 Fault finding 11 Safety feature checks 12 Service history record 13 Declaration of confo...

Page 4: ...our product gives you many years of reliable service Peter Morrey Managing Director DESCRIPTION The Terry 1100W TSL1 Lift is designed to transport a single person in a wheelchair between two floor lev...

Page 5: ...ce If a change of use of the lift is required this should be discussed with the manufacturer supplier as certain alterations may be needed Examples of changes of use are a change of type size and or w...

Page 6: ...the lift is kept clear from debris e g litter and leaves Do not exceed the maximum lifting capacity of 385 kg Always treat your lift with the respect that should be shown to electrical and mechanical...

Page 7: ...ntil the lift reaches the upper or lower level Press one side of the switch to go up press the other side of the switch to go down A key switch is located on the car control panel to isolate the lift...

Page 8: ...ress and maintain pressure on the control button to operate the lift until it stops at the required level If necessary the lift can be stopped at any time by releasing the control button The underside...

Page 9: ...r plate below the car control panel and rotate the cover 2 Then push the lever to the left 3 to lower the lift Please Note If the platform is at the upper level and will not lower follow emergency pro...

Page 10: ...duct If a lifting platform is to be installed in an adverse environment the specifier and supplier shall determine the measures needed to ensure that safe operations are achieved including more regula...

Page 11: ...activated Ensure charger isolation switch is on Activate remote control enabler with key fob Lift rises short distance then stops Obstruction on ramp Remove obstruction on ramp Upper level Lift will n...

Page 12: ...op Folding ramp upper safe edge With the lift at lower level obstruct the upper surface of the ramp and send the lift up the lift should stop within 300mm of travel Upper level gate With the lift at t...

Page 13: ...SERVICE HISTORY RECORD An entry should be added to the following table every time the lift is serviced Date Engineer Company Comments 13...

Page 14: ...008 Electromagnetic Compatibility Product family standard lifts escalators and moving walks Immunity BS6440 2011 Powered lifting platforms for use by disabled persons Person authorised to compile Tech...

Page 15: ...Power supply 240V AC 50 60 Hz Control voltage 24V DC Hydraulic pump power consumption 1200W maximum Hydraulic oil grade T22 Standards Designed and manufactured to BS6440 Service interval Maximum of 1...

Page 16: ...This 1100 W TSL1 has been supplied by 10250c...

Reviews: