background image

2

11

INSTALLATION INSTRUCTIONS

Read the safety instruction first.

Installation of system according standard IEC60728-11 ensures safety of personnel and prevents apparatus against 

damaging due to lightning or other sources of overvoltage surges.

If RF IN connector on the modulator is not used, connect the 75 

Ω 

load supplied.

To wall mount the modulator - screw the modulator to the wall.

Output levels of the modulators must be equalized when they are cascading. Video signal must be connected to the 

modulators inputs when the levels are adjusting. The difference of levels must not exceed 

±

2 dB. Adjacent channel operation 

is possible. If modulators form adjacent channels, it is advisable to adjust V/A signals ratio 16 dB.

 

Do not connect TV antennas to modulator RF IN connector directly. If you intend to combine TV signals of antennas 

and the modulator, plug in booster with output-to-input isolation 

20 dB between antenna output and RF IN connector.

DEFAULT SETTINGS

1. Output channel E02;

2. Audio subcarrier deviation ±50 kHz (when audio signal level 1 kHz is 775 mV);

3. B/G standard; audio subcarrier 5.5 MHz (Preset 

b5

);

4. Test pattern generator OFF (Preset 

no

);

5. Frequency shift none (Preset 

0

);

6. P/S ratio -16 dB (Preset 

I6

);

7. Output signal on (Preset 

on

);

8. Sound subcarriers deviation regulator (Preset 

0

,

 

for MT32C);

9. Sound mode STEREO (Preset 

St

,

 

for MT32C).

OPERATING
ATTENTION! 

A symbol

 

"

LO

" appears in locked mode (see chapter "

PROTECTION FROM UNAUTHORIZED ACCESS"

). 

CHANGING OF SETTINGS

The modulator has two modes of operating:

1. normal: sets after plug in;

Output channel can be selected in normal mode by pressing buttons “-“ or “+” (see tables 2-9).

2. setting: to enter the setting mode press and hold “-“ and “+” buttons simultaneously for 1 second, to exit setting mode 

press and hold “-“ and “+” buttons simultaneously for 1 second.

Select of necessary to change parameter by pressing button “-“ and set necessary mode by pressing “+” button.

1. TV system setting:

a) after switching settings mode, indicator displays current TV system (see table 1);

b) set necessary TV system by pressing “-“ button (see tables 2-8);

c) after TV system changing, modulator sets to first channel of selected TV system (see tables 2-9), other settings 

remains unchanged.

2. test pattern generator:

a) press “-“ button;

b) switching between OFF and ON by pressing button  “+”, 

“no” 

- test pattern generator OFF, 

“t5” 

- test pattern generator ON.

3. fine tuning of video carrier frequency:

a) press button “-“;

b) shift video carrier frequency by pressing button “+” (see table 10).

4.  picture/sound ratio switching:

a) press button “-“;

b) switching between 12 dB and 16 dB by pressing button “+”.

5. output signal switching:

a) press button “-“;

b) switching between RF ON and RF OFF by pressing button “+”, 

“on” 

- RF ON, 

“oF” 

- RF OFF.

6. sound subcarriers deviation regulation (for MT32C):

a) press button “-“;

b) set necessary deviation by pressing button “+“ (see table 11).

7. STEREO/DUAL/MONO mode switching (for MT32C):

a) press button “-“;

b) switch between STEREO/DUAL/MONO mode by pressing button “+“ (

"5t"

- stereo, 

"dU"

- dual, 

"nO-" 

- mono).

PROTECTION FROM UNAUTHORIZED ACCESS

To prevent unauthorized access press buttons "-" and "+" simultaneously twice in 0.5 sec. "

LO

" will briefly be displayed. 

To revert to normal operation, repeat above procedure. "

UL

" will briefly be displayed. The symbol "

LO

" appears, if you try to 

change settings in locked mode.

SOUND SUBCARRIER DEVIATION SETTING

MT32

: When input signal level is from 340 mV to 775 mV in both audio inputs, use a regulator (figure 1, position 6) to set 

the sound subcarrier deviation ± 50 kHz. The factory set sound subcarrier deviation is ± 50 kHz for an input signal level of 

775 mV in both audio inputs.

MT32C

:  The factory set sound subcarier deviation is ±50 kHz for an input signal 1 kHz/775 mV in both audio inputs  

(Preset 

0

). Use software control for audio deviation regulation ±6 dB (see table 11).

OUTPUT SIGNAL LEVEL ADJUSTMENT

Use a regulator (figure 1, position 7) to adjust an output level.

Summary of Contents for MT32

Page 1: ...ity before connecting the modulator to multimedia system be sure that system is installed in accordance to national safety standards devices of multimedia system should have easy access to disconnect them from the mains supply no naked flame sources such as lighted candles should be placed on modulator if the modulator has been kept in cold conditions for a long time keep it in a warm room no less...

Page 2: ...change parameter by pressing button and set necessary mode by pressing button 1 TV system setting a after switching settings mode indicator displays current TV system see table 1 b set necessary TV system by pressing button see tables 2 8 c after TV system changing modulator sets to first channel of selected TV system see tables 2 9 other settings remains unchanged 2 test pattern generator a press...

Page 3: ...uct complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Equipment is double insulated from the mains with functional earthing Functional earthing Connect to the main potential equalization TERRA confirms that this product is in accordance to fol...

Page 4: ...аналов стандартыB G D K Аu I L вметровоми дециметровом диапазонах Модулятор MT32C предназначен для формирования ТВ каналов со стерео звуком стандарты B G D K Аu стерео A2 дуал моно и I L моно в метровом и дециметровом диапазонах Транслируемый сигнал имеет одну боковую полосу Корпус модуляторов соответствует более жестким требованиям по экранированию согласно EN50083 2 класс A Модуляторы предназнач...

Page 5: ...лязащитымодуляторовотнесанкционированногодоступанеобходимодваждывтечении 0 5сек одновременнонажать кнопки и Символ LO появится коротко Для отключения защиты необходимо повторить выше указанные действия Символ UL появится коротко Символ LO появится на экране в случае если управление модулятором заблокировано УСТАНОВКА ДЕВИАЦИИ ПОДНЕСУЩЕЙ ЗВУКОВОГО СИГНАЛА MT32 С помощью регулятора рис 1 поз 6 возмо...

Page 6: ...S25 343 25 349 75 26 S26 351 25 357 75 27 S27 359 25 365 75 28 S28 367 25 373 75 29 S29 375 25 381 75 30 S30 383 25 389 75 31 S31 391 25 397 75 32 S32 399 25 405 75 33 S33 407 25 413 75 34 S34 415 25 421 75 35 S35 423 25 429 75 36 S36 431 25 437 75 37 S37 439 25 445 75 38 S38 447 25 453 75 39 S39 455 25 461 75 40 S40 463 25 469 75 SYSTEM B G b5 Band Displayed Channel Vision C Audio C 01 E1 45 25 5...

Reviews: