12

Diagnostic messages on PC 

Diagnostic information on LCD 

Comments

 

 

Byte 

Bit Nr.

 

 Nr.

  

------Byte #0 - sys_diag----- 

7654 3210

 

‘E01 Main 24 V fail’

 

Diag 

0000  0010 

powering voltage too low 

‘E03 High internal temperature’ 

Diag

 

0000    1000 

high internal temperature,

 

 

 

 

 

ensure better cooling conditions

‘E04 Temperature sensor fail’ 

Diag 

0001   0000 

transmitter is damaged, contact service

E05 EEPROM: value check error’ 

Diag 

0010  0000 

reset the transmitter settings, if the 

‘E06 EEPROM: check sum error’ 

Diag 

0100   0000 

message appears again, contact service

‘E07 EEPROM: initialized  

Diag 

0  1000 0000   

with def. values’

 

     

————Byte #1—————————

‘E10 12V out of range’ 

Diag  1  0000 0001 

‘E11 5V out of range’ 

Diag  1  0000 0010 

‘E12 -5V out of range’ 

Diag 

0000  0100 

transmitter is damaged, contact service

‘E13 3.3V out of range’ 

Diag  1  0000 1000 

‘E14 3.3V overloaded’ 

Diag  1  0001 0000 

‘E15 12V overloaded’ 

Diag  1  0010 0000 

————Byte #2—————————

‘E20 TEC unlocked’ 

Diag  2  0000 0001 

‘E21 TEC overvoltage’ 

Diag  2  0000 0010

‘E22 TEC overcurrent’ 

Diag  2  0000 0100 

‘E23 LD failed’ 

Diag 

0000  1000 

transmitter is damaged, contact service

‘E24 LD degrade’ 

Diag  2  0001 0000 

‘E25 LD shut down failed’ 

Diag  2  0010 0000

‘E26 LD overcurrent’ 

Diag  2  0100 0000

‘E27 Critical temperature’ 

Diag 

1000  0000 

ensure better cooling conditions

————Byte #3—————————

‘E30 Low RF level’ 

Diag 

0000  0001 

increase RF level or set the attenuator  

 

 

 

 

 

“Attn” level properly

‘E31 High RF level’ 

Diag 

0000  0010 

decrease RF level or set the attenuator  

 

 

 

 

 

“Attn” level properly

‘E32 Hazardous RF level’ 

Diag 

0000  0100 

decrease RF level and reset internal 

 

      attenuator 

“Attn”

‘E33 AGC out of range’ 

Diag 

0000  1000 

input RF level cannot be compensated  

 

 

 

 

 

by internal attenuator

Table 1

The diagnostic information is upgrated after power up or transmitter reset.

Note:

 

Bit=1 Error, Bit=0  __ Ok. 

Summary of Contents for MOS212

Page 1: ...Optical transmitter MOS212 User manual English Russian ...

Page 2: ...g control_______________ 4 4 6 Default settings_________________________________ 5 7 Technical specifications__________________________ 5 8 Block diagram__________________________________ 6 9 Operating_____________________________________ 6 9 1 Terra Bus interface ________________________ 6 9 2 Addressing devices_________________________ 6 9 3 Control panel_____________________________ 7 9 4 Contr...

Page 3: ...ed flame sources such as lighted candles should be placed on transmitter If the transmitter has been kept in cold conditions for a long time keep it in a warm room no less than 2 hours before plugging into the mains The ventilation should not be impeded by covering the ventilation openings with items such as newspapers table cloths curtains This product complies with the relevant clauses of the Eu...

Page 4: ...in the operation process Even very micro dust will also affect the transmission quality Dusty fiber optic connector will pollute other connected optic parts If optical receive power and output level of the receiver decline you should clean and maintain fiber active connector Always clean all the fiber optic connectors before setting Reel cleaners or prepackaged alcohol lint free wipes or swabs are...

Page 5: ...dBµV chan 102 On the rear side of cover is indicated accurate RF level for 42 channles signal The RF level for N channel signal recalculate according formula RfLevel N RfLevel 42 10 log N 42 Comments of the front panel indicators if the transmitter addressed the indicator 4 glows green if the transmitter cannot determine subrack s address the indicator 4 is blinking in normal state the indicator 5...

Page 6: ...ice address could be set by configuration DIP switch 10 on the back panel 9 2 Addressing devices Any device in a Terra Bus system has it s group and unit address All addresses must be unique otherwise data collision will happen Most of Terra Bus devices has DIP switches for configuration The last device on the bus the farthest from Terra Bus master must have Last unit switch turned on The rest dev...

Page 7: ...o prevent possible collisions with another equipment connected to Terra Bus To unlock the control panel press then Then the control panel begins scanning the equipment and collecting diagnostic data Results of diagnostics are displayed on LCD display by symbols The first line shows a state of device from the first group the second one from the second group status is OK no active device is detected...

Page 8: ...8 Device selection level Parameter review level Parameter tuning level Figure 2 Simplified algorithm of device selection ...

Page 9: ...tor Attn 4 Attn dB to set attenuation level from 0 to 15 dB by 0 5 dB step 5 Eq dB to set equalizer level from 0 until 10 dB by 0 5 dB step 6 Diag to control diagnostic data Use buttons and to set a parameter Parameter review Then press A blinking cursor or letter E before the parameter name indicates that you get into Parameter tuning level Use buttons and to set a parameter value Displaying a bl...

Page 10: ... Link or CMH Master programs Terra Link version should be 1 3 0 or later to support this device The latest Terra Link software can be downloaded from www terraelectronics com address DOWNLOADS section Figure 3 Terra Link software ThedevicenamewillbelistedatselectedTerraBusaddress seefigure3 Nameingreencolormeans noerrors Red some errors exist The following parameters of the transmitter can be chan...

Page 11: ...case of control panel diagnostic information is displayed as diagnostic bytes Decoding of each bit of diagnostic bytes see in table 2 Value 1 of bit means error value 0 normal condition In case of PC program diagnostic information is decoded automatically and displayed on diagnostic window There are displayed on diagnostic window software version of transmitter transmitter s serial number diagnost...

Page 12: ...ange Diag 1 0000 1000 E14 3 3V overloaded Diag 1 0001 0000 E15 12V overloaded Diag 1 0010 0000 Byte 2 E20 TEC unlocked Diag 2 0000 0001 E21 TEC overvoltage Diag 2 0000 0010 E22 TEC overcurrent Diag 2 0000 0100 E23 LD failed Diag 2 0000 1000 transmitter is damaged contact service E24 LD degrade Diag 2 0001 0000 E25 LD shut down failed Diag 2 0010 0000 E26 LD overcurrent Diag 2 0100 0000 E27 Critica...

Page 13: ...ключения__________________________16 4 6 Конфигурация изготовителя________________________________17 7 Технические характеристики _______________________________17 8 Блок схема ________________________________________________17 9 Управление_______________________________________________18 9 1 Terra Bus интерфейс__________________________________18 9 2 Адресация устройств___________________________...

Page 14: ... быть легко доступна Не устанавливайте передатчик в местах где есть возможность попадания брызг или капель воды Не ставьте сосудов напр ваз с водой или другими жидкостями вблизи передатчика чтобы избежать попадания жидкостей внутрь передатчика Не устанавливайте передатчик вблизи приборов отопления а также в помещениях повышенной влажности На передатчике не должно быть источников открытого пламени ...

Page 15: ...зательств из за порчи оптического разъема Оптические передатчики MOS212 серии оборудованы SC APC типа разъемом Следует обратить внимание что в процессе эксплуатации оборудования каждое оптическое соединение может быть запылено или загрязнено Даже самые маленькие микрочастицы пыли могут негативно воздействовать на качество передачи оптического сигнала При соединении загрязненный конектор может загр...

Page 16: ...тройство выбранo светится зеленый светодиод если модуль не может определить адрес группы мигает зеленый светодиод 2 5 индикатор состояния устройствa в нормальном состоянии светит зеленым светом Если внутренняя диагностическая система обнаруживает ошибку см таблицу 1 стр 24 светодиод становится красным После включения питания и во время переключения на выходной канал индикатор 5 горит желтым светом...

Page 17: ...NR 50 dB CTB 65 dB CSO 58 dB Регулирование усиления 15 dB с шагом 0 5 dB Регулировка наклона АЧХ 10 dB с шагом 0 5 dB Оптический разъем SC APC Потребляемая мощность 198 250 V 50 Hz 10 W Диапазон рабочих температур 00 500 C Габариты Вес в упаковке 485x58 5x171 mm 3 8 kg Условия измерения измерения произведены согласно стандарту EN50083 3 42 CENELEC типичный ВЧ уровень входного сигнала в разъеме RF ...

Page 18: ...10 на задней панели 9 2 Адресация устройств Каждое устройство в системе управления Terra Bus имеет свой адрес группы и адрес устройства Все адреса должны быть уникальные в противном случае может возникнуть коллизия данных Большинство устройств подключаемых к системе управления Terra Bus имеют DIP переключатели для конфигурирования В последнем устройстве в шине наиболее удаленном от управляющего ус...

Page 19: ...борудованием подключенным к шине Terra Bus Чтобы отблокировать панель управления нажмите затем После этого панель управления сканирует оборудование и считывает диагностические данные Результаты диагностики отображаются на LCD дисплее символами В первой строке отображается состояние устройства первой группы в следующей второй Значение символов состояние в норме устройство не идентифицировано пустая...

Page 20: ...ми передатчика 1 Laser включить выключить лазер 2 RF level dBuV контроль ВЧ уровня Замечание параметр RF level dBuV характеризует среднюю мощность входного сигнала Он зависит от уровня входных сигналов и числа каналов 3 Gain ctl включить режим поддержки уровня Manual или Auto Для установки автоматической поддержки постоянного уровня раскачки лазера следует включить Gain ctl в режим Manual установи...

Page 21: ...раметра изменяется и сохраняется в устройстве сразу после каждого нажатия кнопок и а мигающая буква E значит что выбранное значение параметра изменится и сохранится в устройстве только после нажатия кнопки Уровень установки параметра Диагностическая информация Отображениебуквы i впередипараметраозначает чтоэтоинформационныйпараметрионнеподлежит настройке ДляпереходанаУровень выбора параметров без ...

Page 22: ...Terra Link можно скачать с адреса www terraelectronics com секции DOWNLOADS Рис 3 Программа Terra Link Имя устройства будет показано по выбранному Terra Bus адресу см рис 3 Имя зеленого света значит что в устройстве нет ошибок красного цвета есть ошибки С помощью пульта либо ПК возможно управлять следующими установками Рис 4 Окно управления Включить выключить лазер Включить режим поддержки уровня ...

Page 23: ...и значение 0 нормальному состоянию При использовании для управления ПК диагностическая информация расшифровывается автоматически и отображается в соответствующем окне программы управления Кроме диагностической информации согласно Таблицы 1 в диагностическом окне отображается номер версии внутреннего программного обеспечения модуля серийный номер модуля и внутренняя температура Рис 5 Диагностическо...

Page 24: ... 0000 0001 E11 5V out of range Diag 1 0000 0010 E12 5V out of range Diag 1 0000 0100 модуль неисправен обратиться в E13 3 3V out of range Diag 1 0000 1000 сервис E14 3 3V overloaded Diag 1 0001 0000 E15 12V overloaded Diag 1 0010 0000 Byte 2 E20 TEC unlocked Diag 2 0000 0001 E21 TEC overvoltage Diag 2 0000 0010 E22 TEC overcurrent Diag 2 0000 0100 E23 LD failed Diag 2 0000 1000 модуль неисправен о...

Reviews: