Page 14
Assembly instructions - Corner installation
Wall connection is supplied separately. Vertical connec-
tions must be affixed first. To do this, simply remove the
film on the rear. The cellular rubber can then be affixed
flush with the external edge of the heat pump.
Additionaly the horizontal elements are also lined on the
front. This will help ensure an optimum seal.
Before the machine is positioned in the corner, a check
should be carried out to ensure that the wall opening
prepared by the customer has been insulated.
The machine can then be moved into the corner.
The heat pump may only be moved with
the panels fitted.
If there are any air gaps on the outlet or inlet openings
due to the ground being uneven, this can be corrected
using the adjustable machine feet.
Noise
Noise level in the installation room depends on various
factors such as room size, absorption capacity, reflection,
free noise propagation, etc. For this reason, it is important
that the heat pump is situated as far as possible from
noise-sensitive areas. A noise-insulating door should be
fitted.
Significant pressure against the wall
should be avoided.