STOP!

PLEASE READ THE FOLLOWING INFORMATION.

INSTALLER

DF-38 Fountains are among the easiest to install Fountains on the market today. 
To assure you install these models easily and correctly, 

PLEASE READ THESE 

SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK 

YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, 

AND OTHER APPLICABLE CODES.

 

After installation, leave these instructions with the Fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, 

COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS 

GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE 

BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO 

A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC 

TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. 

THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS 

INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD 

BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM 

THE BUILDING PLUMBING SYSTEM.

DF-38

Floor Mount Stone Fountain

Owner’s Manual

Summary of Contents for DF-38

Page 1: ...E PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER ...

Page 2: ... damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psis is not covered by warranty This fountain is to be mounted on a smooth flat finished surface with adequate support structure NOTE Mounting structure must be capable of supporting 300 lb load on fountain Refer to rough in for plumbing Install shut off valve on water supply valve no...

Page 3: ...remove tubing from the fitting relieve water pressure push in on the gray collar while pulling on the tubing see figure 3 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 25mm APPROXIMATELY STREAM HEIGHT Stream height is factory set at 45 50 PSI If supply pressure varies greatly fro...

Page 4: ...Assy 6 70021C Set Screw 8 32 x 25 7 NA Screen 8 45660C Bubbler Assy 9 100322740560 Bubbler Gasket 10 60985551640 Drain Plug Assy 11 170705042830 Basin Receptor 12 15013C Bubbler Tube Assy 13 100147140560 Drain Gasket 14 55913C Drain Fitting 15 75588C Slip Joint Nut 1 1 4 16 66346C Drain Tube 17 55996C Strainer In Line 1 2 3 4 5 7 6 8 9 9 10 11 13 14 12 15 17 16 ...

Reviews: