background image

TROUBLE SHOOTING & MAINTENANCE 

FIGURE 2

 

FIGURE 3

 

FIGURE 4

Orifice Assy:

 Mineral deposits on orifice can cause water flow 

to spurt or not regulate. Mineral deposits may be removed 
from the orifice with a small round file or small diameter wire. 

CAUTION: DO NOT file or cut orifice material.

Stream Regulator:

 If orifice is clean, regulate flow as in 

“STREAM HEIGHT ADJUSTMENT”

 instructions below. If 

replacement is necessary, see parts list for correct regulator 
part number.

Actuation of Quick Connect Water Fittings:

 Cooler is 

provided with lead-free connectors which utilize an o-ring 
water seal. To remove tubing from the fitting, relieve 
water pressure, push in on the gray collar while pulling 
on the tubing (see figure 3).

1/4” O.D TUBE WATER 

INLET TO COOLER

3/8” O.D. UNPLATED 

COPPER TUBE CONNECT 

COLD WATER SUPPLY

NOTE:

 WATER FLOW DIRECTION

BUILDING WATER INLET

SERVICE STOP

(NOT FURNISHED)

1” (25mm) 

APPROXIMATELY

STREAM HEIGHT:

 

Stream height is factory set at 

45-50 PSI. If supply pressure 

varies greatly from this, remove 

items 1 and 2 (See Parts List) and 

adjust screw on item 4. Clockwise 

adjustment will raise stream and 

counter-clockwise adjustment will 

lower stream. For best adjustment, 

stream should hit basin approx. 

6-1/2” from bubbler.

SIMPLY PUSH IN TUBE 

 TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLECT
TO RELEASE TUBE

PUSHING TUBE IN BEFORE PULLING IT 

OUT HELPS TO RELEASE TUBE

A

B

C

3

Summary of Contents for DF-38

Page 1: ...E PERFORMED BY AN AUTHORIZED SERVICE PERSON IMPORTANT THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER ...

Page 2: ... damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psis is not covered by warranty This fountain is to be mounted on a smooth flat finished surface with adequate support structure NOTE Mounting structure must be capable of supporting 300 lb load on fountain Refer to rough in for plumbing Install shut off valve on water supply valve no...

Page 3: ...remove tubing from the fitting relieve water pressure push in on the gray collar while pulling on the tubing see figure 3 1 4 O D TUBE WATER INLET TO COOLER 3 8 O D UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY NOTE WATER FLOW DIRECTION BUILDING WATER INLET SERVICE STOP NOT FURNISHED 1 25mm APPROXIMATELY STREAM HEIGHT Stream height is factory set at 45 50 PSI If supply pressure varies greatly fro...

Page 4: ...Assy 6 70021C Set Screw 8 32 x 25 7 NA Screen 8 45660C Bubbler Assy 9 100322740560 Bubbler Gasket 10 60985551640 Drain Plug Assy 11 170705042830 Basin Receptor 12 15013C Bubbler Tube Assy 13 100147140560 Drain Gasket 14 55913C Drain Fitting 15 75588C Slip Joint Nut 1 1 4 16 66346C Drain Tube 17 55996C Strainer In Line 1 2 3 4 5 7 6 8 9 9 10 11 13 14 12 15 17 16 ...

Reviews: