background image

3

 

 

IMPORTANT SAFEGUARDS 

DANGER

:  

Failure  to  mind  the  dangers,  follow  warnings  and  cautions  in  this  manual  may  result  in 
serious bodily injury or death, or in a fire or an explosion causing damage to property. 

 

 

This stove is primarily for outdoor use. Do not use the stove for permanent indoor heating or cooking. 

 

Do not use the stove in rooms intended for sleeping or permanent residence. 

 

Do not use in or on boats or recreational vehicles. 

 

Do not use on wooden decks, wooden furniture or other combustible surfaces. 

 

Do not use in an explosive atmosphere.  

 

Do  not  store  or  use  gasoline  or  other  flammable  liquids  or  vapors  within  25  feet  (7.5  m)  of  this 
appliance. 

 

Keep the surrounding  area clear and free from combustible materials such as firewood, wet clothing, 
gasoline and other flammable vapors and liquids, etc. 

 

Do not alter stove in any manner. 

 

Do not use the stove unless it is completely assembled and all  components are securely fastened and 
tightened. 

 

This stove is designed to burn natural wood. It is strictly forbidden to use coal and coal briquettes. 

 

Do not start a fire with vapors, chemicals or fluids such as gasoline, engine oil, alcohol, etc. 

 

Do not touch the stove or its parts while they are hot and educate all children of the danger of a high-
temperature appliance. Children and pets should be supervised when they are in the area close to the 
burning stove or in the same room. 

 

Never touch cooking surface, ash drawer and other components to check their temperature. 

 

Do  not  touch  metal  parts  of  the  stove  until  it  has  completely  cooled  to  avoid  burns,  unless  you  are 
wearing protective gear (pot holders, gloves, mittens, etc.). 

 

Wear protective gloves when adding fuel to retain desired heat mode. 

 

Do not let the stove become hot enough for any part to glow red. 

 

Attempts to achieve heat output rates that exceed design specifications can result in steel distortion and 
damage. 

 

Do  not  connect  to  the  electrical  clamp  outlets  electrical  devices  with  power  consumption  over  50W. 
Such connection may damage the electricity generating components. 

 

When  connecting  electrical  devices  to  the  external  outlets  make  sure  that  polarity  of  terminals  is 
correct. 

 

Summary of Contents for INDIGIRKA-2

Page 1: ... installing or operating this equipment 2 Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death 3 Improper installation adjustment alteration service or maintenance can cause injury or property damage 4 For Outdoor Use Only Warmth comes from Siberia INSTALLATION AND OPERATION OWNER S MANUAL Made in Russia ...

Page 2: ... termofor ru eng office termofor ru Table of Contents IMPORTANT SAFEGUARDS 3 CHARACTERISTIC FEATURES 4 SPECIFICATIONS AND DIMENSIONS 5 DESCRIPTION AND DESIGN 7 CLEARANCES 8 INSTALLATION 10 OPERATION 12 OPERATION IN ELECTRICITY GENERATING MODE 13 MAINTENANCE 14 MALFUNCTIONS 15 BASICS OF THERMOELECTRICITY 15 PACKAGING AND TRANSPORTATION 16 LIMITED FIVE YEAR WARRANTY 18 This document is protected by ...

Page 3: ...to burn natural wood It is strictly forbidden to use coal and coal briquettes Do not start a fire with vapors chemicals or fluids such as gasoline engine oil alcohol etc Do not touch the stove or its parts while they are hot and educate all children of the danger of a high temperature appliance Children and pets should be supervised when they are in the area close to the burning stove or in the sa...

Page 4: ...tebook a cell phone an iPod or Reader a camera or watch a portable TV or radio It s not very much but in emergency situations it will allow you to use most portable devices you have used before You may want to keep it safe in your backyard just in case The project was developed by Termofor in association with Kryotherm a company based in Saint Petersburg Russia The same types of generators made by...

Page 5: ...27 mm Height 25 7 652 mm Weight 119 lb 54 kg Door size diameter 7 178 mm Firebox volume 1 45 cu ft 41 l Fuel capacity 1 cu ft 30 l Length of logs maximum 14 36 cm Flue size 3 15 80 mm Flue height minimum 10 ft 3 m Number of flue pipes included 9 pcs Area of heating surface 6 5 sq ft 0 6 sq m Output power 50W Output voltage 12V Table 1 Specifications of the Electricity generating heating and cookin...

Page 6: ...6 Picture 1 External dimensions of the stove INDIGIRKA 2 ...

Page 7: ...oxygen in a heated area The grate is made of a sheet of heat resistant high alloy stainless steel 0 12 3 mm thick and is designed to force the burning process and get a powerful high temperature flame Stove components which do not carry a large thermal working load are made of structural steel of 0 06 1 5 mm thick Two Thermoelectric Generators B25 12 further TEG 8 are installed on the side surface...

Page 8: ... 2 Handle in this model line which is designed with handles at the upper part of the stoves Handles are intended for carrying purposes and for protection of expensive thermoelectric generators from the occasional strokes and falls CLEARANCES The minimum clearances to combustible materials can be decreased by installing fire proof shields between the floor or walls and the stove Those shields must ...

Page 9: ...d by installing fire proof shields between the floor or walls and the stove Those shields must be installed permanently if you plan to use the installation site periodically Fire proof shield recommendations Ceramic tiles 1 25 mm thick or an equivalent non combustible material on fire proof supports or a minimum of 0 06 1 5 mm metal sheet on fire proof supporst Floor clearance to combustible and h...

Page 10: ...lations Flue line should have a minimum number of bends The straight flue line is preferable The flue height measured from the grate to the mouth should be not less than 16 5 ft 5 m 1 Flue cap 2 Bracket 3 Metal sheet on fire proof supports 4 Fence of non combustible material 5 Flue heat insulation 6 Attaching points for additional securing to the floor if needed Picture 3 Example of the stove inst...

Page 11: ...lag basalt wool sand etc The distance from the outer surface of the flue without insulation to the rafters roof battens and other parts of the roof of combustible and semi combustible materials should be not less than 10 250 mm And for a non combustible flue insulation not less than 5 130 mm The space between the flue and roof structures of combustible and semi combustible materials should be cove...

Page 12: ...start of operation the stove should be inspected and repaired A malfunctioning stove is not allowed for operation Attention Make sure that no combustibles are in the area close to the stove Be sure the room is adequately ventilated and the flue is unobstructed 1 Place several wads of crushed paper on the firebox floor 2 Lay dry sticks of kindling on top of the paper 3 Pull out the ash drawer to pr...

Page 13: ...ERATING MODE Attention Before start of operation the stove should be inspected and repaired A malfunctioning stove is not allowed for operation Attention Make sure that no combustibles are in the area close to the stove Be sure the room is adequately ventilated and the flue is unobstructed 1 Place several wads of crushed paper on the firebox floor 2 Lay dry sticks of kindling on top of the paper 3...

Page 14: ...e Ash Drawer to provide more air feed MAINTENANCE Replacement of structural elements should be done only by qualified specialists Danger Clean and maintain the stove only after full cooling off For most efficient and safest operation of the stove provide a good working order of the flue system The inner surface of the flue should be as smooth as possible do not contribute to the accumulation of mo...

Page 15: ...meter of the flue too short length or the flue being too close to trees or higher buildings Malfunction Cause Removal Malfunction of combustion process Deteriorated draft in the flue pipe Clean the flue pipe Streaks on outer surface of the flue Insufficient tightness of flue joints Seal joints with a heat resistant sealant BASICS OF THERMOELECTRICITY If you are curious about how your stove generat...

Page 16: ...e side of the thermoelectric module is cooled and the other is heated If the heat dissipation from the thermoelectric module s hot side is provided efficiently for example by a heat sink the temperature of the cold side could get down to tens of degrees below the ambient temperature In case the current changes its polarity the hot and cold sides would invert Any power plant produces waste heat whi...

Page 17: ...l your Bill of Sale to us We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur Transportation of the stove is allowed only in the original manufacturer packaging by any transport subject to safeguards written on the packaging The stove is painted with heat resistant silicone enamel...

Page 18: ... any incidental or consequential damages caused by defects in the product Adjustments regular maintenance cleaning and temporary repairs or the failure to duplicate the problem in the home is not covered under this warranty This warranty does not extend to or include surface finish on the appliance or terminations door gaskets glass gaskets glass discoloration wool or other ceramic insulating mate...

Page 19: ...s or liability in connection with the sale or use of the appliance In states that do not allow limitations on how long an implied warranty lasts or do not allow exclusion of indirect damage those limitations of exclusions may not apply to you You may also have additional rights not covered in this Limited Five Year Warranty Termofor reserves the right to investigate any and all claims against the ...

Reviews: