background image

18

 

 

LIMITED FIVE-YEAR WARRANTY 

Warranty  starts  on  the  date  of  purchase  by  the  original  owner  (End  User).

  After  installation,  if  any  of  the 

components  manufactured  by  Termofor  Co.  Ltd.  (further  Termofor)  in  the  appliance  are  found  to  be 
defective in materials or workmanship, Termofor will, at company’s option, replace or repair the defective 
components at no charge to the original owner. Termofor will also pay for reasonable labor costs incurred in 
replacing  or  repairing  such  components  for  a  period  of 

components

  warranty.  Any  products  presented  for 

warranty repair must be accompanied by a dated proof of purchase. 

 

FIVE-YEAR WARRANTY 

The  following  components  are  warranted  against  deterioration  not  resulting  from  physical  or  handling 
damage for 5 (five) years to the original owner, subject to proof of purchase: Cooking surface, firebox door, 
firebox door handle, pull-out ash drawer, small gate, chassis with control unit, power outlet 12V. 

 

THREE YEARS WARRANTY 

Termofor warrants the components and materials in your wood stove, which are not mentioned above, to be 
free from manufacturing and material defects for a period of 3 (three) years from date of purchase.  

 

CONDITIONS, EXCLUSIONS AND LIMITATION OF LIABILITY 

 

This  warranty  applies  to  the  original  owner  and  is,  provided  the  purchase  was  made  through  an 
authorized dealer or distributor, and the appliance remains in its original place of installation. 

 

The maximum amount recoverable under this warranty is limited to the purchase price of the product. 

 

In no event shall Termofor be liable for any incidental or consequential damages caused by defects in 
the product. 

 

Adjustments,  regular  maintenance,  cleaning  and  temporary  repairs,  or  the  failure  to  duplicate  the 
problem in the home is not covered under this warranty. 

 

This  warranty  does  not  extend  to  or  include  surface  finish  on  the  appliance  or  terminations,  door 
gaskets,  glass  gaskets,  glass  discoloration,  wool  or  other  ceramic  insulating  materials.  Rust  and/or 
corrosion  on  any  of  the  metal  surfaces,  cast  iron  components,  baffles,  doors,  or  firebox  area  are  not 
covered by this warranty. 

 

Noise  resulting  from  minor  expansion,  contraction,  or  movement  of  certain  parts  is  normal  and 
complaints related to this noise are not covered by this warranty. 

 

Termofor’s  obligation  under  this 

Limited  Five-Year  Warranty 

does  not  extend  to  damages  resulting 

from: (1) installation, operation or maintenance of the appliance not in accordance with the installation 
instructions;  operating  instructions  and  the  listing  agent  identification  label  furnished  with  the 
appliance;  (2)  installation  which  does  not  comply  with  local  building  codes;  (3)  shipping,  improper 
handling,  improper  operation,  abuse,  misuse,  accident  or  non-authorized  repairs;  (4)  environmental 
conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure; (5) 
use  of  fuels  other  than  those  specified  in  the  operating  instructions;  (6)  installation  or  use  of 
components  not  supplied  with  the  appliance  or  any  other  components  not  expressly  authorized  and 
approved by Termofor; and/or (7) modification of the appliance not expressly authorized and approved 
by Termofor in writing. 

 

This  warranty  does  not  apply  to  non-Termofor  components  or  other  accessories  used  in  conjunction 
with installation of this product. 

Summary of Contents for INDIGIRKA-2

Page 1: ... installing or operating this equipment 2 Failure to follow these instructions could result in fire or explosion which could cause property damage personal injury or death 3 Improper installation adjustment alteration service or maintenance can cause injury or property damage 4 For Outdoor Use Only Warmth comes from Siberia INSTALLATION AND OPERATION OWNER S MANUAL Made in Russia ...

Page 2: ... termofor ru eng office termofor ru Table of Contents IMPORTANT SAFEGUARDS 3 CHARACTERISTIC FEATURES 4 SPECIFICATIONS AND DIMENSIONS 5 DESCRIPTION AND DESIGN 7 CLEARANCES 8 INSTALLATION 10 OPERATION 12 OPERATION IN ELECTRICITY GENERATING MODE 13 MAINTENANCE 14 MALFUNCTIONS 15 BASICS OF THERMOELECTRICITY 15 PACKAGING AND TRANSPORTATION 16 LIMITED FIVE YEAR WARRANTY 18 This document is protected by ...

Page 3: ...to burn natural wood It is strictly forbidden to use coal and coal briquettes Do not start a fire with vapors chemicals or fluids such as gasoline engine oil alcohol etc Do not touch the stove or its parts while they are hot and educate all children of the danger of a high temperature appliance Children and pets should be supervised when they are in the area close to the burning stove or in the sa...

Page 4: ...tebook a cell phone an iPod or Reader a camera or watch a portable TV or radio It s not very much but in emergency situations it will allow you to use most portable devices you have used before You may want to keep it safe in your backyard just in case The project was developed by Termofor in association with Kryotherm a company based in Saint Petersburg Russia The same types of generators made by...

Page 5: ...27 mm Height 25 7 652 mm Weight 119 lb 54 kg Door size diameter 7 178 mm Firebox volume 1 45 cu ft 41 l Fuel capacity 1 cu ft 30 l Length of logs maximum 14 36 cm Flue size 3 15 80 mm Flue height minimum 10 ft 3 m Number of flue pipes included 9 pcs Area of heating surface 6 5 sq ft 0 6 sq m Output power 50W Output voltage 12V Table 1 Specifications of the Electricity generating heating and cookin...

Page 6: ...6 Picture 1 External dimensions of the stove INDIGIRKA 2 ...

Page 7: ...oxygen in a heated area The grate is made of a sheet of heat resistant high alloy stainless steel 0 12 3 mm thick and is designed to force the burning process and get a powerful high temperature flame Stove components which do not carry a large thermal working load are made of structural steel of 0 06 1 5 mm thick Two Thermoelectric Generators B25 12 further TEG 8 are installed on the side surface...

Page 8: ... 2 Handle in this model line which is designed with handles at the upper part of the stoves Handles are intended for carrying purposes and for protection of expensive thermoelectric generators from the occasional strokes and falls CLEARANCES The minimum clearances to combustible materials can be decreased by installing fire proof shields between the floor or walls and the stove Those shields must ...

Page 9: ...d by installing fire proof shields between the floor or walls and the stove Those shields must be installed permanently if you plan to use the installation site periodically Fire proof shield recommendations Ceramic tiles 1 25 mm thick or an equivalent non combustible material on fire proof supports or a minimum of 0 06 1 5 mm metal sheet on fire proof supporst Floor clearance to combustible and h...

Page 10: ...lations Flue line should have a minimum number of bends The straight flue line is preferable The flue height measured from the grate to the mouth should be not less than 16 5 ft 5 m 1 Flue cap 2 Bracket 3 Metal sheet on fire proof supports 4 Fence of non combustible material 5 Flue heat insulation 6 Attaching points for additional securing to the floor if needed Picture 3 Example of the stove inst...

Page 11: ...lag basalt wool sand etc The distance from the outer surface of the flue without insulation to the rafters roof battens and other parts of the roof of combustible and semi combustible materials should be not less than 10 250 mm And for a non combustible flue insulation not less than 5 130 mm The space between the flue and roof structures of combustible and semi combustible materials should be cove...

Page 12: ...start of operation the stove should be inspected and repaired A malfunctioning stove is not allowed for operation Attention Make sure that no combustibles are in the area close to the stove Be sure the room is adequately ventilated and the flue is unobstructed 1 Place several wads of crushed paper on the firebox floor 2 Lay dry sticks of kindling on top of the paper 3 Pull out the ash drawer to pr...

Page 13: ...ERATING MODE Attention Before start of operation the stove should be inspected and repaired A malfunctioning stove is not allowed for operation Attention Make sure that no combustibles are in the area close to the stove Be sure the room is adequately ventilated and the flue is unobstructed 1 Place several wads of crushed paper on the firebox floor 2 Lay dry sticks of kindling on top of the paper 3...

Page 14: ...e Ash Drawer to provide more air feed MAINTENANCE Replacement of structural elements should be done only by qualified specialists Danger Clean and maintain the stove only after full cooling off For most efficient and safest operation of the stove provide a good working order of the flue system The inner surface of the flue should be as smooth as possible do not contribute to the accumulation of mo...

Page 15: ...meter of the flue too short length or the flue being too close to trees or higher buildings Malfunction Cause Removal Malfunction of combustion process Deteriorated draft in the flue pipe Clean the flue pipe Streaks on outer surface of the flue Insufficient tightness of flue joints Seal joints with a heat resistant sealant BASICS OF THERMOELECTRICITY If you are curious about how your stove generat...

Page 16: ...e side of the thermoelectric module is cooled and the other is heated If the heat dissipation from the thermoelectric module s hot side is provided efficiently for example by a heat sink the temperature of the cold side could get down to tens of degrees below the ambient temperature In case the current changes its polarity the hot and cold sides would invert Any power plant produces waste heat whi...

Page 17: ...l your Bill of Sale to us We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur Transportation of the stove is allowed only in the original manufacturer packaging by any transport subject to safeguards written on the packaging The stove is painted with heat resistant silicone enamel...

Page 18: ... any incidental or consequential damages caused by defects in the product Adjustments regular maintenance cleaning and temporary repairs or the failure to duplicate the problem in the home is not covered under this warranty This warranty does not extend to or include surface finish on the appliance or terminations door gaskets glass gaskets glass discoloration wool or other ceramic insulating mate...

Page 19: ...s or liability in connection with the sale or use of the appliance In states that do not allow limitations on how long an implied warranty lasts or do not allow exclusion of indirect damage those limitations of exclusions may not apply to you You may also have additional rights not covered in this Limited Five Year Warranty Termofor reserves the right to investigate any and all claims against the ...

Reviews: