H E A T I N G S Y S T E M S
18
Resistance will come on & off line randomly, after the system has reached to set. This will
extend the life of resistances.
7
— Freeze protect:
If the water degree inside the boiler decreases fewer than 6
o
C, the circulation pump stars
and protect the boiler from freezing.
8
— Pump protect:
If the circulation pump does not start, pump starts every day for 1 minute protecting the
system against rust and calcification.
9
— Children Lock:
Pressing the UP and ESC buttons with the same time for 3 seconds, Boiler locks the buttons
until pressing the UP and ESC buttons with the same time for 3 seconds.
13 TERMODINAMIK DIGITAL ELECTRICAL BOILER TECHNICAL DATA
MODELS >>
DEK 6
DEK 9
DEK 12
DEK 18 DEK 24
DEK 30
DEK 36
CAPACITY
kW
6
9
12
18
24
30
36
kcal/h
5160
7740
10320
15488
20650
25813
30975
Working pressure
bar
2
2
2
2
2
2
2
Water volume
L
4,2
4,2
4,2
24
24
24
24
Radiator ―to‖ – ―return‖
inch
¾
¾
¾
¾
¾
¾
¾
Domestic water ―to‖ –
―return‖
inch
½
½
½
½
½
½
½
Power supply connection
cable
qnty/mm
2
2x6
2x10
4x2.5
4x4
4x6
4x10
4x10
Nominal voltage
Volt
220
220
380
380
380
380
380
Fuse
Amp
32
(Monophase)
50
(Monophase)
20
(Three-phase)
32
(Three-phase)
40
(Three-phase)
50
(Three-phase)
63
(Three-phase)
Weight, gross
kg
41
41
41
67
67
67
69
Dimensions
(h x w x d)
mm
723 x 427 x 354
*Power supply connection cable cross sections are calculated according to the line length of
15
meters.
Summary of Contents for DEK 12
Page 1: ...H E A T I N G S Y S T E M S DEK SERIES ELECTRICAL BOILER INSTALLATION AND USAGE MANUAL ...
Page 2: ...H E A T I N G S Y S T E M S ...
Page 17: ...14 H E A T I N G S Y S T E M S Please make sure that boiler is grounded ...
Page 18: ...H E A T I N G S Y S T E M S 15 Please make sure that boiler is grounded 380 V ...