Your boiler must be hung on a wall firmly and rigidly. Water scale should be used for
fine alignment. Minimum clearance and from the floor should be 50 cm, distance from
the ceiling 40 cm. Connections must be done as shown. Not even drop of water
should be permitted.
Do NOT install the boiler in a humid environment such a bathroom.
If the boiler to be installed in an outdoor environment, it must be under/in protective
cover.
All pipes must be connected as shown in the picture No drop of water must be
allowed to leak out.
Please comply with assembly instructions given on page 12 in order to obtain hot
water during summer months.
Pump, boiler ―to & return‖ pipes, safety ―to & return‖ pipes must be installed without
causing any air pockets. Where air bubbles possible, air discharge system must be
installed.
After completion of assembly, system must be flashed twice. This will achieve cleaning
of inside of pipes.
DO NOT FORGET to close ―in & out‖ valves of boiler when flashing the system.
Outside pipes must be insulated to minimize heat loss.
We recommend use of radiator return valves at the returns instead of standard
radiator valves.
Use of decalcification equipment is recommended at the entrance of domestic water
to prevent calcification.
During mounting of the boiler, please use all elements provided to make sure rigid
assembly on the wall.
All wiring and electrical connections must be done in accordance with TSE regulation
(in Turkey), or local codes (other countries).
5. ASSEMBLY & START-UP
Water temperature over 52°C can
cause several burns instantly or
death from scalds. Children,
disabled and elderly are at highest
risk of being scalded. Feel water
before bathing or showering.
Temperature limiting valves are
recommended.
Summary of Contents for DEK 12
Page 1: ...H E A T I N G S Y S T E M S DEK SERIES ELECTRICAL BOILER INSTALLATION AND USAGE MANUAL ...
Page 2: ...H E A T I N G S Y S T E M S ...
Page 17: ...14 H E A T I N G S Y S T E M S Please make sure that boiler is grounded ...
Page 18: ...H E A T I N G S Y S T E M S 15 Please make sure that boiler is grounded 380 V ...