EN
Suitable:
Alternative:
H0 5 VVK (H0 5VVF)
H0 5 RRK (H0 5RRF)
H0 5 VVK (H0 5VVH)
Do not connect using a protective conduit.
5.4 The connecting wire has to be connected to the screwed connecting points of the thermostat/reducing
device.
5.5 The connecting wire has to be placed between the two clamps, then it has to be fixed to the sheath
base with fixing screws.
5.6 It is forbidden to operate the water heater without a protective earth. The protective earth must
comply with the provisions of IEC 60364.
6. COMMISSIONING
After installation, the storage tank can be put into operation. Have the first heating cycle checked by an
expert.
6.1 Open the closing valve (Figure 2., item No. 1) and the hot water faucet but keep the cold water faucet
closed. The water flowing in fills up the storage tank. In order to flush the unit, keep the water flowing for
a few minutes and then close it.
6.2 Connect the appliance to the mains electricity using the main switch. Use the thermostat to set the
desired temperature. During heating, the indicator light is on.
6.3
While heating, the expanding water may leak through the water outlet of the combined
safety valve, therefore this pipe has to be kept open toward the air.